AcoustX D2 User manual

D2 Acoustical Measurement System
Cinema QuickStart Guide
Version 1.77
AcoustX LLC
122 Calistoga Road #318
Santa Rosa, CA 95409
Tel: 707-537-1310
Fax: 707-537-1320
www.acoustx.us

Welcome to the AcoustX D2 Cinema Version and win|RTA software. This
guide will provide you with an overview of setting up and connecting the
hardware, and installing and running the software. The QuickStart Guide
serves as a basic reference for the D2 system, but is not intended as a
detailed guide to operation of the system. More detailed reference
information regarding system operation and the performance of acoustical
tests is provided through separately offered training seminars. Contact
AcoustX regarding the availability of training seminars.
page 2
N O T I C E
© Copyright 2008 AcoustX LLC. All rights reserved.
This manual contains confidential and proprietary information
protected by copyright laws. No part of this publication may
be reproduced, transmitted, transcribed, stored in a retrieval
system, or translated into any language, in any form or by
any means, electronic, mechanical, photocopying, recording,
or otherwise, without the prior written permission of AcoustX.
The information furnished herein is believed to be accurate
and reliable. However, AcoustX assumes no responsibility for
its use, or for any infringements of patents or other rights of
third parties resulting from its use. AcoustX reserves the right
to modify at any time the product functionality and features
where appropriate, without notice.
Version 1.77
L i m i t e d W a r r a n t y
AcoustX LLC warrants the D2 Acoustical Measurement System
hardware and its parts against defects in materials or workmanship
for a period of one (1) year from the original date of purchase.
During period, AcoustX will repair or replace a defective product or
part without charge to the customer. The customer is responsible
for delivering the defective component (or the entire D2 Acoustical
Measurement System, if requested) to AcoustX. The customer must
pay for all shipping and insurance charges transportation of the
defective component(s) to AcoustX for repair. AcoustX will assume
responsibility for shipping and insurance charges involved in
returning the component(s) to the customer. The win|RTA software
is distributed on an “as is” basis, without warranty. AcoustX makes
no representation or warranty, either expressed or implied, with
respect to the software programs, their accuracy, quality, or fitness
for a specific purpose. AcoustX shall have no liability to the
purchaser, or to any other person or entity with respect to any
liability, loss, or damage caused, or alleged to have been caused
either directly or indirectly by the software contained on the
distribution disk. This includes, but is not limited to, interruption of
service, loss of data, time, or profits, or consequential damages
resulting from the use of the software. If the distribution medium is
defective, you may return it for a replacement within the warranty
period.

page 3
CONNECTION DIAGRAM
Equipment in Auditorium
Microphones
Equipment in Projection Booth
Once installed, these USB
devices should always be
connected to the same
physical USB port for
proper operation.
Use only USB ports that
are built in to the
computer, not external
hubs.
Line In
1/4" phone
Line Out
1/4" phone
Input from
Plexer
5-pin female
mini-XLR
75'
interconnect
cable
Plexer output
5-pin male
mini-XLR
Host computer
Each microphone must be
connected to its assigned
input by matching the
marker on the connecter to
the symbol on the Plexer.

page 4
Plexer Panel Diagrams
Front Panel View Top Panel View
On-Off Switch
Microphone selection indicator LEDs
If the microphone selection
remains unchanged for 10
minutes, LED 4 flashes to
indicate power-save mode.
Normal operation resumes
when the microphone
selection is changed.
Plexer output to Controller
(5-pin male mini-XLR)
Microphone Inputs 1-4
(3-pin female mini-XLR)
Controller Panel Diagrams
Top Panel View Left Panel View
Right Panel View
Microphone selection LEDs
Status LED indicates an error
when lit (USB cable must be
re-inserted to reset the
Controller)
Input from Plexer
(5-pin female mini-XLR)Balanced line out to USBPre
Pin jack connectors for pink noise
relay switch closure. Used to
trigger cinema processor pink noise
USB port to connect
to host computer
Connect to same port
on computer each time

page 5
USBPre Panel Diagrams
Top Panel View
Input (Left) Panel View Output (Right) Panel View
Input gain controls
Level control for Channel 1 is preset to
MINIUM or FULLY COUNTERCLOCKWISE.
Aluminum cap prevents accidental
movement of input control. Channel 2 is also
calibrated when knob is set to minimum gain.
Input selection
indicators for
Channels 1 & 2
Input selectors for
Channels 1 & 2. Line
Input must be manually
selected for both
channels using these
buttons.
Input level indicators
for Channels 1 & 2Power LED
NOTE: Greyed-out areas of the drawings represent
controls and inputs/outputs that are not used by the
D2 Acoustical Measurement System.
The D2 uses the Line 1 input by
default. Line 2 can be selected
in software. Both channels are
active in X-Y modes. Pink noise outputs
USB connection to host
computer.
Connect to same port on
computer each time.

Installation
1. Install the USBPre Digital Audio Interface first.
Please refer to the documentation accompanying
the USBPre for complete installation and operating
instructions. Select "Preferred Installation" after
inserting the USBPre software CD. Refer to the
connection diagram and to the USBPre panel
diagrams in this document for information on proper
connection of the device. (Note: The USBPre must
be connected directly to a USB input on the
computer instead of through an external USB hub.)
2. Connect the D2 Controller as shown in the
connection diagram. The Controller must be
connnected directly to a USB input on the computer
instead of through an external USB hub. When the
Controller is connected, the computer should
prompt for drivers for the device. The necessary
drivers are found on the win|RTA CD.
3. Insert the win|RTA software CD into an available
drive on the host computer. Open the CD and
double click on "Setup". Follow the instructions and
prompts of the installation procedure to install the
win|RTA software onto the host computer. A short-
cut icon for win|RTA can be placed on the desktop
during the installation proedure.
4. Connect the remaining components of the D2
Acoustical Measurement System (D2 Plexer and
microphones) as shown in the connection and panel
diagrams.
5. Install the 9V alkaline battery in the Plexer opening
the battery cover on the back panel. If you want to use a
rechargeable battery, a 9V NiMH battery with a 250 mAh
or greater rating is recommended.
6. Double-click on the short-cut icon placed on the
desktop to start the win|RTA software. Note that a
default configuration (preferences) will be created the
first time the program is executed. The user should
customize this information as appropriate in the Config
panels.
7. After installation, enable microphone calibration by
selecting mic cal numbers in the Config menu. (See the
Config diagrams later in this document.) The
microphone serial numbers are assigned with Mic 1 as
the lowest serial number through Mic 4 as the highest
serial number. The "Mic Cal" checkbox must be
selected to enable mic calibration.
8. Next, with the USBPre connected, select the
"Interfaces" window in Config. Press "Select", and
choose USBPre from the list of available interfaces.
9. Finally, click "Save Configuration" to store the
preferences to disk.
page 6

Main Software Screen
Print screen
Input channel
Clear screen and
reset to default
settings
Save the
current
measurement
(Shift-Click to
export as text)
Exit
win|RTA
SPL/ Main
reading
window
Select file to
display as File
A (left bar when
A and B
selected)
Select file to display
as File B (right bar
when A and B
selected)
Filename
for File B
Set
analyzer
mode
Measurement
units
Open Config
window
Set length
of timed
average
Timed
average
countown
Reference
line
Change
Reference
line
Turn on
analyzer Stop all
processes
Pink noise
ON/OFF
Vertical
scale
Screen
response
Vertical
resolution
Frequency
resolution
Display
offset
File view
mode
User definable function keys. Shift key enables
new row of keys. Click on F-key number to
display and set funtion choices.
Filter band
center
frequencies
SPECIAL KEYS AND FUNCTIONS
- ESC key kills all processes
- PgUp/PgDn or mouse wheel moves reference line
- Shift shows new row of function keys
- Shift-click on Save button to export as text (.TXT)
- Click and drag mouse on display to zoom view in RTA
mode
- Right-click displays edit menu when in comment
- Hold cursor over filename field to see full pathname
CTT MODE KEYS
- Up/Down arrow moves among menu selections
- Left/Right arrow moves in or out of current menu
- Alt-Left Arrow moves up one levele when in a data entry
field
- Shift-click on Home CTT Coverage test button to
rename
X-Y
- Shift-click-drag moves both channel gains together
page 7
Start
selected
test

Technician name
Organization
Name of theatre
Select data
directory
page 8
Selected data directory
Defaults to "My Documents"
Set software options for type
of room under test
Set default units
for measurements
Display octave markers
Show bar values when cursor is
moved over a bar
Enable balloon help
Set length of User Average
Set display for
Cat. No. 566
test film (film
projectors)
Enable Variable
X-curve
Configuration Screen: Profile and Display
Write
configuration
data to disk

page 9
Disable one or more
microphones
Enable and load microphone
calibration files.
Adjust the gain of individual
microphones.
Select audio
interface
Enable D2 Controller
Configuration Screen: Microphones and Interfaces

page 10
Configure PINK Button behavior
Select test signal output port
Set units of measure and level for outputs
Enable outputs. In Analog mode, the
channels can be named.
Configuration Screen: Outputs
Select Input
Select input channel
(Mic selection is on main screen)

page 11
X-Y Oscilloscope
Mode Select
Set channel to
display on RTA
Set measurement
units
Adjust X gain
Move X-Y disiplay
horizontally
Adust Y gain Move X-Y display
vertically

page 12
Dual Trace Oscilloscope
Adjust Channel 1
vertical position
Set
measurement
units
Mode select
Adjust trigger level
Select channel for
triggering
Set vertical
gain
Set
measurement
units
Set vertical
gain
Adjust time base
Adjust Channel 2
vertical position
Adjust refresh rate
Other manuals for D2
4