ACTii AC3828 User manual

GSM SECURITY ALARM
SYSTEM
User Manual

System Overview
Introduction
Wireless GSM Burglar Alarm with voice prompt for commercial and home use is built on leading
microprocessor technology with advanced GSM digital signal processing power. It is a highly
integrated system of digital speech, mobile messages, multiple modes of wireless coding, long
distance home appliances controlling, SMS Messages identification and other technologies.
When alarming, it will automatically notify users via mobile network about the possible break in
using either voice calling or SMS messaging. It is stable, reliable and safe. With its user friendly
design and without the need of fixed telephone network, it can be widely used in different
locations including shops, offices, villas, residential estate, garage, warehouse, to name just a
few. It is an ideal choice to protect your properties and personnel safety.
Features
■ Work with GSM SIM card , and voice prompt ,easy of use .
■ Two groups of Scheduled Arming and Disarming function.each time disarmed you can
select the included period of time, eliminating of need of the manual procedure, realizing the
beauty of automatic controls.
■ Four wired zone, six wireless zone, can be set as AWAY, STAY, INTELLIGENT or
CLOSED types ,and each zone can be equipped with many accessories.
■ Using phone (cellular phone) or SMS Messages to configure and control the Panel
remotely.
■ Six groups of phone numbers for voice calling and three groups for SMS Messages, 10
seconds ISD automatic leaving message record
■ Telephone (phone) long distance telephone control for arming, disarming, monitoring,
remote announcement.
■ One group of normally open signal output, which can be externally linked to electrical
appliances with alarming output.
■ Many built in speeches, letting alarm receivers know the accurate alerting location
■ SMS Messages content from alarming Defense zone can be customized.
■ Wireless intelligent study coding, compatible with PT2262 normal encoding and a million
group encoding, convenient and flexible for adding or reducing accessories.Maximum support
50 remote control and 50 sensors.
■ Telephone (phone) long distance telecontrol for arming, disarming, monitoring,
talkbacking, shouting, and controlling appliances, etc.
■ EEPROM information protection, information never lost
■ Built in Ni Hi rechargeable battery and automatically switchable upon power failure, and
notification will be sent via SMS.
■ Panel integrated with either dual band, triple band, quad band GSM/GPRS industrial
graded module, stable and reliable.
.1 System Components and Usage
ARM
The system is at a fully ready status where all detectors are activated in a working state, when
the some events ( burglar, fire, gas leak, etc ) happened and detected, , alarm system alarm
right away.
In a ARM status, the panel [ ARM ] light is on.

To activate using remote control: press [ ARM ] key once.
STAY ARM
This is for partial arming of the alarm system when there are people at home, only some of the
selected sensors are activated and could be triggered by events.
In a STAY ARM status, the panel [ARM ] light is flashing.
To activate using remote control: press [STAY] key once.
DISARM
All sensors are deactivated and will not be respond to any events.
In a DISARM status, the panel [ ARM ] light is off
To activate using remote control: press [DISARM] key once.
EMERGENCY
When an emergency occurs, press emergency button on the remote or the * button on panel to
activate alarm.
. System Setup
. .1 Panel Setup
Alarm panel should be installed at a central location with best transmission to all the
wireless sensors and accessories. Keep the panel well away from large metal objects or
household appliances with high-frequency interference, and avoid barriers such as
concrete walls with metal frame inside and fire doors.
function Indications Description
Built in speaker short "beep" once KeyTip
"beep", "beep" two short
tones
Exit configuration or learnt
succeed
"beep", "beep", "beep" three
short tones
Error indication
Voice prompt The prompt voice of the
function and status
ARM LED Light up Alarm panel at ARM state
Rapid flashes Alarm panel at STAY ARM
state
Flash slowly Alarm panel at delay ARM or
recording state
Off Alarm panel at DISARM state
Defense zone indicating
light(1~6)
Light up A(1~6) zone alarm
One LED flashing This zone enter delay alarm
state
All flashing Unloaded SIM card or
loaded wrong
GSM Signal indicator Flash one time for 1s GSM Signal weak or
unloaded SIM card

Flash one time for 3s GSM signals and SIM card
are normal
3 Installation of Panel
3.1 Alarm Panel Initial Setup
Load the SIM Card, connect telephone line, fix the GSM Antenna, connect the power and other
cables if any, then power up alarm panel. The alarm panel voice prompt "Welcome to use alarm
system", and start self test the GSM network, “GSM Signal indicator ” flash one time each 1s
means it's searching the GSM signals ,when“GSM Signal indicator ” flash one time each 3s
means GSM signals and SIM card are normal.( it takes about 10 seconds or so for
searching).Remark : if all defence zone indicating light(6) is flashing and the alarm panel restart
for 20s means Unloaded SIM card or loaded wrong.
Upon everything working properly, the battery switch should be at the [ON] position for
continuous charging.
3. Pre-record Voice Message
Alarm panel will play a pre recorded voice message after the alarm call when a pre set phone
number upon alarm. To record customized message:
Press and hold "SET"Key 3s to enter the configuration mode:
Speak your message at the panel for recording
System will record 10 Seconds and then automatically exit; or press any key to end
whenever your message end.
Press"SET"Key to exit setup status.
3.3 Enable or disable the GSM Module:
System default the GSM module is on . if the user not installed the SIM card , the host will
restart until find SIM card and GSM signal.
Remark: If set the GSM module to off, the alarm system only used as the live alarm
system,only cleared the police , can not dialed the phone alarm number.Moreover ,the host
without the SIM card would not restart when you closed the GSM module.
3.3.1 Close GSM module method:
● In the disarm status, press [SET] key for 3 seconds, release it when the recording light on .
● Wait 2seconds, and then hold the [SET] key 3 seconds once again, the panel will respond
with "di ,di,di" three times means changing into the state of closed the GSM module .
● Turn on the power supply again after power off . the panel will prompt "welcome to use alarm
system ", and "di di di" three times ,means the GSM module is off.
3.3. Open GSM module method:
● In the disarm status, press [SET] key for 3 seconds, release it when the recording light on .
● Wait 2seconds, and then hold the [SET] key 3 seconds once again, the panel will respond
with " di,di" twice means changing into the state of open the GSM module .
● Turn on the power supply again after power off . the panel will prompt "welcome to use alarm
system ", and "di" once ,means the GSM module is on.
Remark:If the GSM module is off,the alarm system would be can not read the SIM card .

3.4 Add Remote Control:
Press 【SET 】 key 1s ,all defence zone indicator light would be on and voice prompt" add
remote control " to enter the configuration mode:
Then press any key of the remote control to send a signal to the alarm panel, voice prompt "
learning successful", beep only once means the remote control has been configured before.
Alarm panel can configure up to 50 remote control of different addressing. Upon completion
press 【SET】 6 times every 1s to exit the configuration mode.
3.5 Delete the remote control:
Press
【SET】
key 1s , alarm panel beep once ,all defence zone indicator light would be on and
voice prompt" add remote control " to enter the configuration mode:
nd then hold
【SET】
key 3s ,alarm panel beep twice ,all defence zone indicator is off ,means all
remote control deleted.
3.6 Add detector
Press
【SET】
key 1s , alarm panel beep once ,all defence zone indicator light would be on and
voice prompt" add remote control " to enter the configuration mode:
Press【SET】 key 1s again ,the first defence zone indicator light on ,and voice prompt "
learning one zone " to enter the configuration mode.
Then trigger the detector to send a signal to the alarm panel, voice prompt " learning
successful", beep only once means the detector has been configured before.
Press【SET】1s again ,the second defence zone indicator light on ,and voice prompt "
learning second zone " to enter the configuration mode.And so on, for each of the rest
defence zones .
Last press
【SET】
again ,alarm panel would be beep twice , and all indicator light off to exit
the configuration mode. Alarm panel can configure up to 50 sensors of different addressing.
3.7 Delete detector
Delete the sensor of first defence zone : press 【SET】 twice ,and then press 【SET】 3s
when the first defence zone indicator light on ,the alarm panel beep twice ,means delete
the detector of first zone successfully.
Delete the sensor of second defence zone : press 【SET】three times ,and then press
【SET 】3s when the second defence zone indicator light on ,the alarm panel beep
twice ,means delete the detector of second zone successfully.
Delete the sensor of third defence zone : press
【SET】
Four times ,and then press
【SET】
3s when the third defence zone indicator light on ,the alarm panel beep twice , means
delete the detector of third zone successfully .
Delete the sensor of fourth defence zone : press
【SET】
five times ,and then press
【SET】
3s when the fourth defence zone indicator light on ,the alarm panel beep twice , means
delete the detector of fourth zone successfully .
Delete the sensor of fifth defence zone : press
【SET】
six times ,and then press
【SET】
3s
when the fifth defence zone indicator light on ,the alarm panel beep twice , means delete
the detector of fifth zone successfully .

Delete the sensor of sixth defence zone : press SET seven times ,and then press SET 3s
when the sixth defence zone indicator light on ,the alarm panel beep twice , means delete
the detector of sixth zone successfully . 4 Command Reference
This system supports two methods of configuration including telephone set and SMS
messaging. Following are examples how instructions are given via one of the three
methods of setting
Example: you want to change the first phone number for voice calling to 13899998888:
Method 1: By telephone set
Calling into the alarm panel, upon connected, alarm panel will ask for password, it is 1234 as
the default, then press #, and then press 3113899998888# , press the * then press # to exit
configuration mode.
Method : Using SMS
On your mobile phone, compose a SMS message as 12343113899998888# and send to your
alarm panel.
4.1 Commands for Configuration
Set up voice alarm
phone number
To set the 1st group to the 6th group of voice alarm phone number 【
1-6 】 indicates that the first group to the sixth group alarm number
correspondingly.
Example: If the user wants to set 13812345678 for the first set of voice
alarm phone number
Method one: Remote calling into the alarm panel put in password (initial
password: 1234 ) when being asked, then press the # key, hear the voice
prompt means the host into setting state.
In remote setting, press a digital then the host will broadcast one digital
speech, if press a digital not broadcast speech or press once broadcast
second speech mean setting not correct. Press* key to exit.
Method two: Send SMS messages 12343113812345678# to a alarm
panel (which at the beginning of 1234 is the user password), the alarm
panel will reply with SMS message "Group 1 phone number :
13812345678” to confirm the 1st group alarm phone number is set
to13812345678 successfully.
For users using the telephone line extension, you should dial the number
13812345678+*+extension number.Here one * means wait 1s,Two *
means wait 2s .
Remark:If enable the dialing of power off function ,when power off,it
will automatically dial the preset telephone number ,and voice prompt
"zero zone alarm .
Syntax:
【 3 】 + 【 1 6 】 +
【Phone number】
+
【
# 】
Delete voice alarm
phone number
Used to delete the first groups to the sixth group alert phone
numbers

Example: If you want to delete the first set of telephone alarm number,
Method one: After entering the telephone remote setting status, press
31#.
Method two: Send SMS message 123431# On the alarm panel, alarm
panel reply " Group 1 phone number: ” to confirm the 1st group alarm
phone number has been removed.
Syntax:
【3】
+
【1
6】+【#】
Set phone number
to receive SMS
message
To set the first group to the third group of phone number for SMS
message. When alarm panel is alert, it sends a SMS message to the
three sets of numbers one by one.
Example: If the user wants to set 13812345678 SMS for the first group of
SMS message
Method one:
After calling and connected to the panel from remote, press
3713812345678#
Method two: Send SMS message 12343713812345678# to the panel.
Remark:
When AC power off or on ,it will send SMS message to the preset
telephone number.
Syntax:
【3】+【7 9 】+
【Phone number】
+
【#】
Delete SMS phone
number
Used to delete the first group to SMS of the third group police
number
Example: If you want to delete the first set of SMS message phone
number,
Method one: After calling and connected to the panel from remote, press
37#
Method two: Send SMS message 123437# to the panel
Syntax:
【3】+【7 9】+【#】
Password
modification
Used to modify the user password, the default user password is 1 34
Example: If you want to set up a new user password 4321
Method one: After calling and connected to the panel from remote, press
504321#
Method two: Send SMS message 1234504321#
Syntax:
【50】 + 【4 digits
new password 】 +
【#】
Set delay for system
arm
Upon armed from the remote control or alarm panel, the alarm panel
is set to delay 0 - 99 before at the ready status of ARM. The system
default is 00 seconds.
Example: users need to set the delay time for 60 Seconds.
Method one: After calling and connected to the panel from remote, press
5160#
Method two: Send SMS messages12345160#
Syntax:
【51】 + 【 00 99
Second 】 + 【 # 】
Set the time of delay
for alarming
Set the time of delay upon alram, it can be set to 0-99 seconds, the
system default is 00 seconds.

Example: the user needs to set the alarm delay time to 60 Seconds.
Method one: After calling and connected to the panel from remote, press
5260#.
Method two: Send SMS message 12345260#
Syntax:
【52 】 + 【00 99
Second】 + 【#】
Set length of Siren
sound
Set alarm length of sounding when panel alarm, could be set to 0- 0
minutes, factory default is 1 minute.
Example: you want to make a siren sound 5 Minutes.
Method one: After calling and connected to the panel from remote, press
5305#.
Method two:Send SMS messages12345305#
Syntax:
【53 】 + 【 00 20
Minutes】+ 【 # 】
Alarm linkage
function on or off
Enable or disable the alarm linkage function. 1 is enabled and 0 is
disabled, the system default is 1.Example: users need to set the alarm
linkage function off,
Method one:After calling and connected to the panel from remote,
press540#
Method two:Send SMS message 1234540#
Method three: 1234200#
1Remark:If enable the alarm linkage function,when alarming,the relay
absorption would change the circuit condition between NO and COM . The
time of relay actuation is the same with siren sound time. When disable
the alarm linkage function ,the relay of the panel can remote control the
home appliance.After calling and connected to the panel from remote,input
the password,press 9 ,the relay on,0 OFF. Or send SMS
12343#ON ,12344# Means OFF 。Can control the power which below
1000W ,such as electric cooker ,lamp,water suction pumpetc.
Syntax:
【54】
+
【0/1】
+
【#】
Set audible
confirmation for
remote control
operation
1 means on and 0 means closed, the default is on.
Example: set panel without sound when remote control is sending signal.
Method one: After calling and connected to the panel from remote, press
550#
Method two:Send SMS messages 1234550#
Syntax:
【55】
+
【 0/1 】
+
【 #
】
Set date and time
settings
Set the system date and time
Example: it is now 1st of July of 2012 9 :00 : 00 am
Method one: After calling and connected to the panel from remote, press
56120901090000#.
Method two: Send SMS message123456120901090000#
Syntax:
【56 】 + 【2 digits
year】 + 【01 12 The
Month 】 + 【01 31
Day】
+
【00 23 Hour】
+
【00 59 Minute】
+
【
00 59 Second " + 【 #
】

The first set of
Scheduled arm and
disarm time setting
To set the time for scheduled arm and disarm,
Example: set up the first group scheduled time to arm at 22 : 00 pm and
disarm at 07 : 00 am, this is valid for Monday, Tuesday, Wednesday,
Thursday and Friday of each week.
Method one: After calling and connected to the panel from remote, press
572200070012345#
Method two: Send SMS message 1234572200070012345#
Remark:set the arm time and disarm time to be 24:00,would be closed the
scheduled arm/disarm function .
Syntax:
【 57 】 + 【 AAAA
Scheduled time of
arm 】+ 【 BBBB
Scheduled disarmed
time 】
+
【 Number of
week 】 + 【 # 】
The second set of
Scheduled arm and
disarm time setting
To set the time for scheduled arm and disarm,
Example: set up the second group scheduled time to arm at 12 : 00 pm
and disarm at 13 : 00 am, this is valid for Monday, Tuesday, Wednesday,
Thursday ,Friday,Saturday and Sunday of each week.
Method one: After calling and connected to the panel from remote, press
58120013001234567#
Method two: Send SMS message 123458120013001234567#
Remark:set the arm time and disarm time to be 24:00,would be closed the
scheduled arm/disarm function .
Syntax:
【 58 】 + 【 AAAA
Scheduled time of
arm 】+ 【 BBBB
Scheduled disarmed
time 】
+
【 Number of
week 】 + 【 # 】
Set the type of
defense zone
To set 6 wireless zones type, 01~06 represents 1-6zone number, 1-5
represents one of the 5 zone type:
1. NORMAL
2. STAY ARM
3. INTELLIGENT
4. EMERGENCY
5. CLOSED
The last 0/1 represents 0 siren of panel produce no sound upon alarming
while 1 is sounded.
Example: Set zone number 2 as STAY zone type, and siren not sound
upon alarming
Method one: After calling and connected to the panel from remote, press
600220#
Method two: Send SMS message 1234600220#
Syntax:
【60】
+
【01 06 zone
number 】 + 【 1 5
Type 】
+
【 0/1 】
+
【
# 】
Set mode of wired
alarm zone
Set wired alarm zone to NO or NC. The zone number of 07-10 are
wired defense zones, system default is 07-10 are wired zones with NO

mode.
1-5 represents one of the 5 zone type:
1.NORMAL
2.STAY ARM
3.INTELLIGENT
4.EMERGENCY
5.CLOSED
The first 0/1 represents 0 siren of panel produce no sound upon alarming
while 1 is sounded.
The second 0/1 ,0 means NO and 1 means NC
NO means short circuit to alarm
NC means open circuit to alarm
Example: Set 7 zone to NORMAL, NC alarm, without sound when
alarming ,
Method one: After calling and connected to the panel from remote,
press6107101#
Method two: Send SMS message 12346107101#
Remark:
1) set 7 zone to NO alarm ,in the arm status ,when7 and GND to be short
circuit condition ,the alarm system would be alarming.
2) set 7 zone to NC alarm ,in the arm status ,when 7 and GND to be open
circuit condition ,the alarm system would be alarming.
Usually Suitable for connect the alarm port of the wired accessories.
Syntax:
【61】+【07-10,zone
number 】+【1
5】
+【0/1】
+
【0/1】
+
【#】
Siren volume
adjustment
Valid value is from 00 to 99 as largest, system default is the largest.
Example: users need to set volume to 50 。
Method one: After calling and connected to the panel from remote, press
6250#
Method two:Send SMS message 12346250#
Syntax:
【6 】
+
【00-99】
+
【#】
Auto dial-up
function when
power off
When power off ,auto dial function on or off .1 for on ,0 for off ,the
panel would not dial the pre-set phone number.Default is 0.
Example: user want to receive the call from the panel when power off .
Method one: After calling and connected to the panel from remote, press
641#
Method two:Send SMS message1234641#
Syntax:
【64】+【0/1】+【#】
Set audible
confirmation from
panel to on or off
Alarm panel will produce audible confirmation beep upon receipt of
signal from remote control. 1 is on, 0 is off, default is on.
Example: users need to disable the audible confirmation.
Method one:After calling and connected to the panel from remote,
press110#
Method two:Send SMS message 1234110#
Syntax:
【11】+【0/1】+【#】
Enable or disable
the SMS Messaging
1 is on and 0 is off. Default is on
Example: the user will need to turn off the text messaging feature

Method one: After calling and connected to the panel from remote,
press120#
Method two:Send SMS message 1234120#
Syntax:
【12】+【0/1】+【#】
Restore factory
setting
System restore factory setting
Method one:After calling and connected to the panel from remote,
press130000#
Method two: Send SMS message1234130000#
Remark:This feature will restore all settings to factory default apart from
the configuration of sensors and remote control.
Syntax:
【13】
+
【0000】
+
【#】
Total System Reset Disconnect power to the alarm panel, turned off the battery switch alarm
panel, then press and hold the alarm panel of SET button while power on.
The system will respond with long “beep” for 5 seconds, then can release
SET button. The system is now totally reset. All configuration has been
cleared, all sensors and remote controlled are deleted and password is
restored to original 1234.
Syntax:
Press and hold the
SETand power on.
Note: Other than the SMS commands for assigning specific phone number for certain zone,
alarm panel will respond to all other SMS commands by replying confirmation of setting by
SMS.
4. Commands of System Enquiries
The following instructions are only for SMS command to control panel remotely:
Remote SMS disarm Send SMS message 12340# into alarm panel
Note: 1234 is the password
0#
Remote SMS NORMAL
arm
Send SMS messages 12341# to set the alarm panel to ARM
1#
Remote SMS STAY arm Send SMS message 12342# to set alarm panel to STAY ARM.
#
Remote SMS turn on
relay
Send SMS message 12343# to turn on the relay of the alarm panel
3#
Remote SMS turn off
relay
Send SMS messages 12344# to turn off the relay of the alarm panel
4#
Query the AC power
status
Send SMS messages 12346# to the alarm panel, the alarm panel replies
AC power ON or AC power OFF.
6#
Query the alarm panel
general settings
Query the alarm panel status included: arm/disarm, relay status, status
of integrated alarm, status of SMS messaging, status of remote

operation, password, delay alarming setting, delay arm setting, length of
time of siren sounding, volume of siren, keyboard locking status, audible
confirmation
Example: Send SMS message 123420# to the alarm panel, the alarm
panel replies with a list of related setting:
Arming → armstatus
Relay out off → relay off
Voice on → voice on
Dial on → Auto dial the preset phone alarm number when power off .
Alarm out on →alarm linkage on
Send SMS on→SMS messaging on
Remote set on→Siren sound when remote control operation
Password:1234→the password is 1234
Alarm delay:00s→delay alarming 0 second
Arm delay:00s→ delay arm 0 second
Siren on 1 min→ siren sounding time 1 minute
Siren VOL:99→ volume of siren 99
0+【#】
Query voice alarm
phone number
Return a list of 1st to 6th phone number group for voice alarm and 1st to 3rd
SMS alarm number .1 6 for 1st to 6th phone alarm number ,7 9 for 1st to
3rd SMS alarm number
Example: Send 123421# to the alarm panel, the alarm panel replies " 1 :
13712345678” means the first voice alarm phone number is
13712345678
Remark: phone alarm number can be the same as SMS alarm number .
1+【#】
Query the system time
and scheduled
arm/disarm time
Query the system time
Example: Send 123422# to the alarm panel, the alarm panel replies
“System clock :2012 07 01 12:00”. Means the system is now 1st of July
of 2011 12 :00 : 00 am.
AMR 1:22:00
DISARM 1:07:00 12345
ARM 2:24:00
DISARM 2:24:00 1234567
Means: the first group scheduled time to arm at 22 : 00 pm and
disarm at 07:00 am, this is valid for Monday, Tuesday, Wednesday,
Thursday and Friday of each week.
The second scheduled arm/disarm time function is disabled
+【#】
Query the type and
siren setting of all
defence zones
Query the type and siren setting of all defense zone
Example: Send 123423# to the alarm panel,
Reply message format and analytic:

1:Normal On means the first zone is normal zone,siren on.
2:Stay Off means the second zone for STAY alarm, siren off
3: Smart On means the third zone for INTELLIGENT,siren on
4: Urgent On means the fourth zone for EMERGENCY,siren on
5: Off On means the fifth zone for CLOSE, in close state
6: Normal On means the sisth zone for NORMAL,siren on
7: Normal On NO means the seventh zone is NORMAL,siren on,and
short circuit to alarm
8:Normal On NC means the eighth zone is NORMAL, siren on,and open
circuit to alarm.
9:Normal on NO means the ninth zone is NORMAL,siren on,
And short circuit to alarm
10: Normal siren NO means the tenth zone is NORMAL,siren will
alarm ,and short circuit to alarm
3+【#】
Query the customized
SMS message content
Query zone 00 99 the content of SMS message customized.
Example: Send 123480# to the alarm panel to query for zone 01
message content.
Reply message format and analytic:
1:The first zone message content"1 zone alarm "
2:The second zone message content"2 zone alarm "
3:ditto
10:ditto
80 +【#】
Customize the SMS
message for certain
zone
Used to customize the SMS message for zone 1 9.(this content is sent
into the first to the third SMS message numbers users reset after this
zone alarming,content confined within 12 Letters)
Example: Send message “123481 Front Door Alarm#” to the alarm panel
will set alarm panel to send SMS message “Front Door Alarm” upon
zone 1st alarm being triggered
Reply message format and analytic:
1:the first door open means the first zone message content to "1 door
open"
2:2 zone means the second zone message content"2 zone alarm"
3: 3 zone means the third zone message content"3 zone alarm"
4: ditto
10:0 zone means the tenth zone message content "10 zone alarm "
8+
【1-9zone number】
+
【message content】
+【#】
Customize the SMS
message for 10th zone
Set the tenth zone message content
Example:change the tenth zone message to "1 win open" send a
message "123490 1 win open" to the panel.
90+ 【message
content】+【#】
Note: "1 34" string shown above table all represents the password. User can change
password and thus should adjust the commands listed accordingly.

5 Remote Control of Panel
5.1 After receiving the Panel Alert:
After Panel alerts, it will automatically dial the preset telephone number for three times until
connected ,and send SMS message to the preset telephone number . When the user picks up
the phone, a piece of pre recorded voice message will be played back immediately and let the
receiver noted about the event. Upon receiving the call, it can also control the alarm panel
remotely via the phone (according to the command below). User will not be asked for password
upon connected and alarm will automatically hang up call within receiving any instruction within
20 seconds.
[1] key: arming [2] key: disarming
[3] key: monitoring open [4] key: monitoring closed
[5] key: turn on announcement [6] key: turn off announcement
[7] key: siren ringing [8] key: stop siren sound
[9] key: turn on relay [0] key: turn off relay
[*] key: hang up, system will not dial the next number on list.
Remark:
-If not hang up using [*] key or disarm using [2] key, the system will retry to call the next
phone numbers on list until one connected.
-Panel will not ask for password when dialing out upon alarming.
Remark: monitoring time is 20 seconds. If continue to monitor, user needs to press 3 key again.
Press [3]+[5] To support talkback function, the host needs to connect to another passive
loudspeaker, which are 8 ohm and its power above 0.5 W.
5. Remote Dialing In Operation:
Remote control operations can be done via any phone. You can just dial into the alarm panel
and user will be asked for password upon connected and alarm will automatically hang up call
within receiving any instruction within 20 seconds or password is incorrect. (original password
1234)
[1] key: arming [2] key: disarming
[3] key: monitoring open [4] key: monitoring closed
[5] key: turn on announcement [6] key: turn off announcement
[7] key: siren ringing [8] key: stop siren sound
[9] key: turn on relay [0] key: turn off relay
[*] key: hang up,
[#] key: Enter the system remote configuration mode, Without receiving no instruction, the panel
will automatically hang up after 20 seconds.
6 Types of Alarm Zone
6.1 Definitions of Zones
The alarm supports 10 distinguishable defense zones and they can be classified into one of the5
Zone Types with their respective characteristics.

Type
ID
Zone Type Interpretation
1 NORMAL Defense
Zone
the Panel only works on the arming status. When disarming,
there is no response.
2 STAY Defense zone
(AT HOME Defense
zone)
can be shut off solely through the remote control (keyboard)
to avoid the Infrared Detectors and other in room detectors
from misinformation when master is resting at home.
3 INTELLIGENT Defense
zone:
if the detector in the Defense zone is triggered only once, it
will not immediately alarm. But if being triggered once again
within 30 seconds after the first triggering, it will alarm
immediately.
4 EMERGENCY Defense
zone:
no matter on arming or disarming status, if detector is
triggered it will alert. Usually used in connecting with Smoke
Detectors, Gas Detectors and emergency button, etc.
5 CLOSED Defense
zone:
no matter arming or disarming status, detectors will not alert
even being triggered.
6. Default
Operation
password
1234
Siren volume 99 Alarm linkage Enable
1 10zone type Normal GSM moudle Enable
Siren sound 1minute Audible confirmation for remote operation Enable
Delay ARM 0s Delay alarming 0s
7 10wired zone
alarm type
NO 1 10zone alarm Siren sound
SMS message Enable 1 10Zone SMS message content
6.3 Fitting parameters:
-Input voltage: DC9V 12V
-Standby currents: < 25 mA
-Alarm current: < 450 mA
Wireless frequency: 315/433/868/915MHZ ,2262/1.5 4.7M , EV1527/300K
-GSM Format: Support GSM850/900/1800/1900MHz (option)
Backup battery: NI HI AAA*6 DC7.24V
Alarm loudness: 110dB
-Detailed parameters: The alarm should be compatible with PT2262, PT2240 and EV1527.
Using PT2262 encoding, the resistance is recommended 1.5M 4.7M; using with EV1527
encoding, the resistance by 300K, data recommended 1010.
Table of contents