AAP QUICKFIT User manual

QUICKFIT
INSTALLHOOK-UPSHEET
FOR
ESLKIT
REV 2.01 OP

PROGRAMMING STARTS
Page2
Changing Entrydelay’s
Zone1is set at 20secondsbydefault.
This is howlong thepanelgives youto get inand disarmitafter asensor has beentripped.
Each sensorhas its owndelayfrom0to 9999seconds. Ifyouhaveto pass asensor to get to thekeypad thenit
shouldhaveadelay.InInstaller Modepress <PROGRAM><144><ENTER> (thenselectthezoneyouwish
to change 1-8)and <ENTER> (thenputinthenew time 0-9999)and <ENTER>.
P144 E1E[][ ][ ][ ]E(zone1defaultdelayis 20 seconds).
P144 E2E[][ ][ ][ ]E(zone2defaultdelayis 0seconds).
Changing Exitdelay
This is howlongyouhaveto get outofthehousebeforethepanel goes into alarmmode.
Youcanhavefrom0to 255second selected below.InInstaller Modepress <PROGRAM> <60> ENTER<1>
<ENTER> (thenputinthenew time 0-255)and <ENTER>.
P60 E1E[][ ][ ]E(thedefaulttime is 30seconds).
OutputResetTimes
This is howlong thesirenswill soundbeforeturnoff automatically.Time is inseconds.
InInstaller Modepress <PROGRAM> <40> <ENTER> (thentheoutputyouwishto change 1or 2)and
<ENTER> (nowputinthenew reset time 0-9999)and <ENTER>.
P40 E1E[][ ][ ][ ]E(output1defaultreset timeis 300seconds).
P40 E2E[][ ][ ][ ]E (output2defaultreset timeis 300seconds).
Changing Installercode
Thereis onlyoneinstaller code, this is for youto remember. As defaultitis 000000.
YoumustbeinInstaller modeto changethecode, press <PROGRAM><25><ENTER><1><ENTER>
(thenputinyour new code)and <ENTER>.
P25 E1E[][ ][ ][ ][ ][ ] E
Changing/Adding usercodes
Thepanelhas theabilitytohaveup to100user codes. Theycanhavea 1to 6digit code. User Codes arestored
inat Address 1,slots1to 100.TochangecodesyoumustbeinInstaller or Clientmode, thenpress
<PROGRAM> <1><ENTER> thentheslotyouwishto changei.e. <1> and then<ENTER>, thekeypad will
flashbacktheexisting code(defaultcodeis 123).Nowkeyinyour new codei.e.(456)and press <ENTER>
thenew codewill bethenflashback.
P1E1E[][ ][ ][ ][][ ]E(This is the master codedefault code=123)P1E2E[][ ][ ][ ][][ ]E
P1E3E[][ ][ ][ ][][ ]EP1E4E[][ ][ ][ ][][ ]E
P1E5E[][ ][ ][ ][][ ]EP1E6E[][ ][ ][ ][][ ]E
P1E7E[][ ][ ][ ][][ ]EP1E8E[][ ][ ][ ][][ ]E
P1E9E[][ ][ ][ ][][ ]EP1E10E [][ ][ ][ ][ ][ ]E
Entering Installer mode
Ifyouwantto get into program modepress <PROGRAM> followed byyourinstaller code, defaultset to 000000
and <ENTER> to confirm.
Exiting Installer Mode
Press the <PROGRAM> button, then <ENTER>.

Whenyouhavefinished theprogramming options, aquicktestis required toconfirmall hardwareand
softwareis working correctly.
Run throughthesteps belowand tick thebox ifitoperates successfully.
Makesureno oneis moving around thehouse, as this could affectthetest.
1. Thekeypad should nothaveany zonelightson.Thereadylightshould beonsteady.
Are allthelightsright?yesif no therecould beawiring problem checkyour work.
2. Get someoneelseto walkinfrontofthesensors, thecorresponding zone1or 2should come on.
Dotheycomeonatthe righttime?yes if no therecould beawiring problem checkyour work.
3. Nowtestall theuser codes. Startbytyping inusercode1followed byenter, thekeypad should start
beeping as itarms, thentypeitinagain, thekeypad should go quiet as itdisarms.
Repeat this testfor all usercodes.
Do allofthe codesarm anddisarmthepanel? yes if no gobackand checkthe user codeslots,to
see weather the right codes has been entered.
4. Nextto press theARM button, tosee ifthereis enoughtime to get outofthehouse,beforetheexitdelay
beeps stop.
Canyougetoutbeforethebeepsstop?yesif no you will need to extend the exit delay.
5. Nowwiththepanel ARMEDsee ifyoucanget backinsideto thekeypad and disarmthealarmbeforethe
sirens go off.
Canyoudisarm beforethe sirensgooff?yes if no you will need to increasethe entrydelay times.
6. Thefinal testis to makesurethe sirensand strobe go offafter theentrydelayhas finished. So armthe
alarm, waitfor thebeeps to stop thenmoveinfrontofasensor, thekeypad should startbeeping againandas
soonas theentrydelayis up thesirens andstrobewill go off, oncechecked enterauser codeto disarmand
turnofthesounders.
Doestheexternalsirenwork?yes
Doestheexternalstrobe work? yes
Doesthe internalsirenwork? yes if no toany of thesecheckwiring and polarity of devices.
Thealarmpanel is nowreadyfor general use
Are youhappywiththeinstallation?
yes
Signhere.Date. //
Page3
TESTING
Having Troublegetting thesystem working?
Try ourtroubleshooting guide
ThisQRCodewill linkyou to it

Page4
DIALLERSETUP- FORMONITORING STATION
Your Elite S-Lite Controller is equipped withanonboard dialler, capableofcommunicating incontactid.
Ifyouarerequired toconnectto acentral monitoringstationyouwill need tocomplete thefollowing steps.
Contactamonitoring stationofyour choice, theywill issueyouanaccountnumber and telephonenumber.
Name ofmonitoring station___________________________Contactphonenumber_____________
Your Accountnumber [][ ][ ][ ]
Telephonenumber 1[][ ][ ][ ][ ][ ][ ][ ][ ][ ][ ]
Telephonenumber 2[][ ][ ][ ][ ][ ][ ][ ][ ][ ][ ](this is optional)
Step 1:Connectacross theincoming phonelinebetweenthestreet and thefirstjack point.
Step 2:Enablethedialler. InInstaller Modepress <PROGRAM> <175><ENTER><1> <ENTER>
(thenturnONoption1)and <ENTER>.
P175 E1E1E
Step 3:Accountnumber. InInstaller Modepress <PROGRAM> <62><ENTER><1><ENTER>
(thenputinthe4digitaccountnumber) <ENTER>.
i.e. P62 E1E1234E (thenew accountcodewould be1234)
Step 4: Phonenumber 1, InInstaller Modepress <PROGRAM> <181> <ENTER><1> <ENTER>
(nowkeyinyour givenphonenumber1)and <ENTER>.
I.e. P181 E1E095551234 E (thenew phonenumber 1would be095551234)
Phonenumber 2, InInstaller Modepress <PROGRAM> <181> <ENTER><2> <ENTER>
(nowkeyinyour givenphonenumber2)and <ENTER>.
I.e. P181 E2E095554321 E (thenew phonenumber 2would be095554321)
Step 5:Preparefor dialler test. Firstwe will temporarilydisablesounders. InInstaller Modepress
<PROGRAM> <25> <ENTER><9><ENTER><1> <2><ENTER> (outputs 1& 2have
beendisabled until anArmcyclehas takenplace).
P25 E9E12E
Step 6:Exitprogram modebypressing andholding <PROGRAM>
Step 7:Testing. Press the <ARM> buttontheexitdelaywill start. Whenitstopswalkinfrontofeach
detector, thengo back to thekeypad tosee ifLED’s 1& 2arenowflashing and thekeypad is
squealing. Assoonas theentrydelayhas finished, thepanel should startdiallingout. Youwont
beableto hear itdial out,butifyoupick up aphoneinthehouseitshould nothaveadial tone.
Leavethepanelfor about2minutes thenkeyinausercode i.e.<123> followed by <ENTER>.
Thepanel should nowbedisarmed.
Step 8:Confirming. Nowcontactthemonitoringstationand askthem iftheyreceived 3differentmonitoring
messages fromyour accountcode.Theyshould be:
Alarm activationonzone 1.
Alarm activationonzone 2.
Alarm restored.
DiallerSetupisComplete

DIALLERSETUP- FORPERSONALMONITORING
IfyouhaveanAnaloguetelephonelineconnected tothepanel, thebuilt-inDomesticDial optioncanbechosen.
InDomesticDial theAlarmwill call acellphoneor land-lineand playasirentonedownthelineintheeventofan
alarmactivation.Thecall thenneeds to beacknowledged bypressing the#keyonthephonehand set.
TheESLcontrol panelhas4telephonenumberslot(5to 8)setup andreadyfor DomesticDial.
Note. Do Notusenumber slots 1,2,3or 4theseareforMonitoring stationuseonly
Telephonenumber 5[][ ][ ][ ][ ][ ][ ][ ][ ][ ][ ](domesticdial slot1)
Telephonenumber 6[][ ][ ][ ][ ][ ][ ][ ][ ][ ][ ](domesticdial slot2)
Telephonenumber 7[][ ][ ][ ][ ][ ][ ][ ][ ][ ][ ](domesticdial slot3)
Telephonenumber 8[][ ][ ][ ][ ][ ][ ][ ][ ][ ][ ](domesticdial slot4)
Step 1:Connectacross theincoming phonelinebetweenthestreet and thefirstjack point.
Step 2:Enablethedialler. InInstaller Modepress <PROGRAM> <175><ENTER><1> <ENTER>
(thenturnONoption 1)and <ENTER>.
i.e. P175 E1E1E
Step 3: Adding PhoneNumbers, InInstaller Modepress <PROGRAM><181> <ENTER><5-8>
<ENTER> (nowkeyinyour phonenumber)and <ENTER>.
P181 E5E[][ ][ ][ ][ ][ ][ ][ ][ ][ ][ ][ ]E
P181 E6E[][ ][ ][ ][ ][ ][ ][ ][ ][ ][ ][ ]E
P181 E7E[][ ][ ][ ][ ][ ][ ][ ][ ][ ][ ][ ]E
P181 E8E[][ ][ ][ ][ ][ ][ ][ ][ ][ ][ ][ ]E
i.e. P181 E5E021555123 E (thefirstdomesticdial phonenumber would be021555123)
Step 4:Exitprogram modebypressing andholding <PROGRAM>
Step 5:Testing. Withthephonelearntinto slot1onhand, Armthepanel and waitfor theexitdelayto
finish.ThenwalkinfrontofaPIR, theentrydelayshould start, followed bythesirens sounding.
Disarmthepanel to makethesirens stop. Thephoneshould nowberinging, answer itand listen.
Asirentoneshould playfor3seconds on2seconds off. Whilethetoneis offpress and hold the#
keyto acknowledgethecall, thealarmpanel will thenhang up. (ifthe#keywill nothangup the
panel tryadifferentkey)
Page5
Whatamore advanced personalmonitoring option?
FollowthisQRCodelinkforour
SmartPhoneApp Option

E16LEDKP
CableEntryPoint
PCBfits here
17 voltAC
power leads
HARDWARECONFIGURATION
Page6
Screw PCB
downin
thesepoints.
BATTERY
GOESHERE WIRE230V
MAINSIN
HERE.
INSIDEVEIWOF PLASTICCABINET
POP OUT CABLECLAMP FORMAINSLEAD.
Endviewof
Keypad
Carefullyslideaflatbladescrewdriver
intoslotstoremoveback.
Removingbackfromkeypad.
CUT THISSUPPORT OFF

5YearWarranty
Thank you forpurchasinganotherqualityArrowhead Product.
Weguaranteetoreplaceor repairArrowhead Manufactured productfoundto
be faultydue todefectivematerialsorworkmanship for
aperiodof 5yearsfromdateofpurchase.
The customershall assoonaspracticable after the discoveryof anysuchdefect orfault,
returnthe goodsordefectivepartsthereof, toArrowhead AlarmProducts.
Freight toand fromourstoresis yourcare.
The companyshallnotbe liablefor anydirect orconsequential lossor damage attributedtothe fault.
Nor shall the companybeliablefor anypersonalinjuryofanykind attributable tothefault.
The customerwill keep the companyindemnifiedagainst anysuchclaim.
Anyattempt bythecustomertorepair thegoodswithout written permission bythe companycouldvoid the Warranty.
Page7
NewESL Control Board
TheESL ControlboardisacombinationofbothElite-SandElite-SLiteBoards.
Thenew boardhasacompletelynew defaultconfiguration, making installationfast, smarter
and withless chanceoferror.
Hardware:
8xHardwiredZone Inputs
Still withthe ability toZone Doubleto16
4xOpen Collector Outputs(NegativeSwitching)
1xRelayOutput (Clean 1A NO&NC Contacts)
3xIndividuallyFused12VoltOutlets
All withFuseMonitoring
DefaultProgramming Configuration:
UserGroups
Slots1to39 areforstandard PinCodeoperation(originalconfiguration)
Slots40 to49 areforRadio pendantsdesiredtoArmonly
Slots50 to59 areforRadio pendantsdesiredtoDisarmonly
Slots60 to69 areforRadio pendantsdesiredtoDisarmandActivateOutput 3
Slots70 to79 areforRadio pendantsdesiredtoDisarmandActivateOutput 4
Slots80 to89 areforRadio pendantsdesiredtoCausean Instant Panic
Slots90 to99 areconfiguredfor the TRXMAINS control
Slot 100 hasbeen setupasaspecialInstallerUserCodelocation
Outputs
1&2areasbeforefor InternalandExternalSirens, 300 secondresettime
3&4havebeen Linkedfor UserandAppcontrol,2secondreset time
5to8areready for User&AppcontrolandlinkedtoKP,5secondresettime
Zones
1to8areHardwiredEnabledzones,all Staymodeready
9to16 areWireless Enabledzones,all Staymodeready
Keypads
1&2boththesekeypadsgiveentry delaybeeps
3to8havebeen linkedtothiercorrespondingOutput foraccess control
8hasalso been setupforfull AppControl for Outputs3to8(asIP-Module=KP8)
Phone Numbers
1to4theseslotsareforCID reporting(monitoringstationor IP-Module/ESL APPKIT)
5to8theseslotsareforDomesticreportingandonly have2max.retry'sset

E16LED KP
RESISTOR COLOUR CODES:
2K2 = = RED, RED, RED, GOLD.
4K7 =
= YELLOW, VIOLET, RED, GOLD.
8K2 = = GREY, RED, RED, GOLD.
SIREN
TAMP
STROBE
EOL
SS-1C
SATELLITE SIREN
ESL CONNECTION DIAGRAM
230V
AC
Input
Lin
Dat
Clk
Neg
Pos
Gnd 12V 1 C 2 3 C 4 5 C 6 7 C 8 Tmp Gnd 12V
Outputs
Gnd 12V 1 2 3 4
ESL
V908.12c
In
Lin
Out AC
AC
Red
Blk
NO
NC
C
17V
AC
Zone 1 Passive
Infra-Red Detector
0v
12v
EOL TAMPER EOL RELAY
2k2
Zone 2 Passive
Infra-Red Detector
0v
12v
EOL TAMPER EOL RELAY
2k2
HOUSE
PHONES
PHONE LINE
OFF THE
STREET
SILICONE FILLED CRIMPS
TELEPHONE WIRING OPTION 1: Standard analogue
PIEZO
SIREN
P
N
Keypad
Terminal
ON
12
0V
C
D
ANT
RX-16 MF349
v090618
Optional Radio Receiver Connects here:
PIR2
PIR1
INTERNAL
EXTERNAL
KEYPAD1
RECEIVER
PHONE LINE
OFF THE
STREET
WITH ADSL ENABLED ADSL MODEM
LINE
PHONE
DSL008
ADSL LINE FILTER
SILICONE FILLED
TELEPHONE WIRING OPTION 2: high speed internet (broadband)
TELEPHONE WIRING OPTION 3: with Voice over IP System
Internet
VoIP phone lines will Not work
Internet Connection
IP-MODULE
Li
n
Da
t
Cl
12 Volt
SLA
Battery
Fit a 2K2 Resistor in
Unused Zone Terminals
GARAGE DOOR1
Garage Door 1
Garage Door Push
to Operate Button
If you don’t wire the TMP
terminal to the External
Siren you must put a link
wire from TMP to GND