C NTR L PANEL
E L
s
PTI NAL REMTE LED
s
WIRING DETAILS
1
23
4
5
6
7
1
23
4
5
6
7
cable
screen
Contact No. Function
1 +Ve IN (diode connection on C4408DR only)
2+Ve UT (diode connection on C4408DR only)
3 Remote LED +Ve
40V
50V
6Screen
7Screen
BASE CONNECTION DETAILS
• Correct polarity must be observed.
• Do not mount bases on uneven surfaces.
• Terminals can accept 0.25-2.5 mm2wiring.
• Screened cables are recommended.
BUILT-IN
DI DE
(C4408DR only)
cable
screen
• 9 - 33 Vdc operating line voltage.
• Relay switches up to 1 A @ 24 Vdc and is
controlled by detector’s remote LED output.
• ptional connection to a BF318 Remote LED.
• Example uses: Door release, CCTV, etc.
N
C
NC
C4408DR C4408R
N
C
NC