ADC HiGain H2TU-C-319 List 4E User manual

HiGain
HiGain
ADC DSL Systems, Inc.
14402 Franklin Avenue
Tustin, CA 92780-7013
Tel: 714.832.9922
Fax: 714.832.9924
Technical Assistance
800.638.0031
714.730.3222
FCC Certification
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to
Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment. This equipment generates, uses,
and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual,
may cause harmful interference to radio communications. Operation of this equipment in a residential area is
likely to cause harmful interference in which case the user will be required to correct the interference at his
own expense.
Limited Warranty
Product warranty is determined by your service agreement. Contact your sales representative or Customer
Service for details.
Modifications
Any changes or modifications made to this device that are not expressly approved by ADC DSL Systems, Inc.
voids the user's warranty.
All wiring external to the products should follow the provisions of the current edition of the National Electrical
Code.
Standards Compliance
This equipment has been tested and verified to comply with the applicable sections of the following standards:
❑GR 63-CORE - Network Equipment-Building System (NEBS) Requirements
❑GR 1089-CORE - Electromagnetic Compatibility and Electrical Safety
❑Binational standard, UL-1950/CSA-C22.2 No. 950-95: Safety of Information Technology Equipment
Trademark Information
ADC is a registered trademark of ADC Telecommunications, Inc. HiGainis a registered trademark of PairGain
Technologies, Inc. Other product names mentioned in this installation guide are used for identification
purposes only and may be trademarks or registered trademarks of their respective companies
Copyright Information
©Copyright 2001 ADC DSL Systems, Inc. All rights reserved. Information contained in this document is
company private to ADC DSL Systems, Inc., and shall not be modified, used, copied, reproduced or disclosed
in whole or in part without the written consent of ADC.
THE H2TU-C-319 LIST 2E
The ADC®HiGain®product family is the industry’s first practical implementation of
High bit-rate Digital Subscriber Line 2 (HDSL2). When an H2TU-C-319 List 2E line
unit is used in conjunction with a HiGain remote unit (H2TU-R), the system provides
1.552 Mbps transmission on one unconditioned copper pair over the full Carrier
Service Area (CSA) range. The CSA includes loops up to 12,000 feet of 24 AWG or
9,000 feet of 26 AWG wire, including bridged taps. These line units can be used with
HiGain regenerators (H2RUs) to extend the CSA range. Regenerator support will be
available in future product enhancements.
FEATURES
SPECIFICATIONS
•Front-panel status LED, craft port, and
four-character status display •Payload or HiGain loopback source identification
•Ultra-low wander •Bit Error Rate (BER) alarm options
•Grounded loop detection •Dual DSX-1 outputs
•Three-span range with two regenerators
(36 kft, 24 AWG) •HiGain maintenance screens for inventory,
provisioning, troubleshooting, and
performance monitoring
•Metallic test access option •Performance Report Messaging (SPRM and
NPRM)
•Flash download of firmware updates •Digital Data Service (DDS) latching loopback
option
Operating Temperature -40 °F to +149 °F (-40 °C to +65 °C)
Operating Humidity 5% to 95% non-condensing
HDSL2 Span Voltage 0, -185 Vdc
Mounting 3192 high-density shelf
HDSL2 Line Rate 1.552 Mbps Overlapped Pulse Amplitude
Modulation Transmission with Interlocking
Spectra (OPTIS)
HDSL2 Output +16.8 dBm ±0.5 dB, 135 Ω
Maximum Loop Attenuation 35 dB at 196 KHz, 135 Ω
DSX-1 Line Rate 1.544 Mbps ±200 bps
DSX-1 Line Format Alternate Mark Inversion (AMI) or Bipolar with
8-zero Substitution (B8ZS)
DSX-1 Frame Format Extended SuperFrame (ESF), SuperFrame (SF) or
Unframed (UNFR)
DSX-1 Pulse Output 6 V pk-pk, pre-equalized for 0 to 655 feet of ABAM
cable
DSX-1 Input Level +1.5 to -7.5 dB DSX
INSTALLATION
To install the H2TU-C-319, align the H2TU-C with the slot guides, then slide the line
unit into the enclosure. You should hear a snap when the H2TU-C-319 is properly
seated.
POWER-UP SEQUENCE
When the H2TU-C powers up, the four-character display illuminates and reports
status messages.
If the H2TU-C is unable to communicate with the next span device, it displays various
alarm and status messages.
If the H2TU-C is able to communicate with the next span device, the following occurs:
1While as devices in the system are being acquired the Status LED flashes red.
Once the entire system is operating without any alarms (the T1 signal must be
present), the Status LED illuminates steady green.
2The four-character display reports margin (SNR) readings (shouldbe ≥6 dB) and
loop attenuation (should be <35 dB @196 KHz).
3If an alarm condition exists after the system powers up, it is reported on the
display. (The H2TU-C reports alarms if no T1 signal is applied.)
PROVISIONING
After installing the H2TU-C, perform these basic provisioning tasks by accessing the
HiGain HDSL2 logon screen. Refer to the onscreen Help menu for navigational aids.
1Connect a maintenance terminal to the craft port (see front-panel illustration
inside), then press + to refresh the logon screen, if necessary.
2Select the Config menu, Date and Time, and type the date and time.
3Select the Inventory menu and type in the unit ID numbers.
4Change the settings of any system parameters, if necessary, by selecting the
Config menu, Standard Options or ADC Options. (Configuration options can
also be set from the front panel using the MODE and SEL buttons.)
5Once the H2TU-C is successfully installed and provisioned, access the Monitor
or Performance menus to clear the Performance and Alarm History screens to
ensure useful data.
Continued
CTRL R
Þ
´,#R¶9m¨
1203509
January 9, 2001
Product Number: 150-2400-25
CLEI Code: VACH4XYC
Catalog: LTPH-QI-1027-02, Issue 2
S
E
L
M
O
D
E
SETUP
STATUS
R
S
2
3
2
O
U
T
I
N
B
R
G
B
R
G
L
I
N
E
L
I
N
E
H
2
T
U
*
C
3
1
9
DCE
2E
HiGain
HDSL2
L
H2TU-C-319 LIST 2E
LINE UNIT
LOOPBACK TESTING
Initiate loopback testing from the Monitor screen or use the MODE and SEL buttons. The
inband codes below can also be sent by a test set.
Four-character display
System option buttons (for manual
setting of system parameters)
MUX DSX-1 port test access jacks
Card handle
List number
Displays status, provisioning, and
alarm messages. See tables below
for a list of message descriptions.
Use MODE and SEL to manually modify user options,
initiate loopbacks, and display DSX-1 line parameters.
Connect standard test equipment.
Craft port provisioning
To access all system maintenance, provisioning
and performance screens, connect a standard
9-pin terminal cable between the serial port on a PC
and the H2TU-C craft port.
1
2
3
4
Press the MODE button for 1 second and release.
The front panel alternately displays the first
system parameter and its current setting.
Press SEL to step through all possible settings for
the displayed parameter.
Press MODE to update the parameter and advance
to the next parameter.
After scrolling through all the parameters, press SEL
to confirm changes when prompted with a CONF NO
message, or press MODE to cancel all changes.
LINE
BRG
Provides splitting jack access to
(IN) and from (OUT) the HDSL2 span
at the MUX port DSX-1 interface.
Provides non-intrusive bridging jack
access to (IN) and from (OUT) the
HDSL2 span at the MUX port DSX-1
interface. Allows monitoring of theT1
payloads.
MaintenanceTerminal Modem Settings
9600 baud
8 data bits
No parity
1 stop bit
Hardware flow control:OFF
Terminal emulation software:VT-100
S
E
L
M
O
D
E
O
U
T
I
N
B
R
G
B
R
G
L
I
N
E
L
I
N
E
H
2
T
U
*
C
3
1
9
R
S
2
3
2
SETUP
STATUS
Status LED
A CREM or NLOC loopback
is in effect.
Green LED Normal operation.
Flashing Red LED HDSL2 acquisition.
Red LED Fuse alarm.
Flashing Red LED System alarm.
Yellow LED
FlashingYellow LED System is in ARM mode.
Off Line power is off.
(Configuration
number and
CLEI code
label on outside
of handle)
2E
Card-edge connector
3
4
5
6
C
D
E
F
H7
8
J
9
K
10
L
GND
HDSL2SpanTip HDSL2SpanRing
LOSAlarmBus Management bus
Frame GND -48V BAT
Fusealarm
1
A
DSX-1Ring(IN)
2
B
DSX-1Ring1(OUT) To AUX Port
DSX-1Ring(IN)
DSX-1Ring1(OUT) To MUXPort
DSX-1TxTip(In)
DSX-1RcvTip1(Out)
DSX-1TxTip(In)
DSX-1RcvTip1(Out)
MTAFTip (Out)
MTAFTip (In)
MTAFRing (Out)
MTAFRing (In)
MetallicTest
Access(TB6) MetallicTest
Access(TB6)
HiGain
HDSL2
L
DCE
To AUX Port
To MUXPort
GNLB Loopback Commands
Loopback Inband Code Out of Band Code Description
NLOC 1111000 (4 in 7) DSX-1 signal is looped back to the network at the
H2TU-C.
NREM 1110000 (3 in 7) DSX-1 signal is looped back to the network at the
H2TU-R.
SMJK 100000
11000
1111-1111-0100-1000
(FF48) DSX-1 signal is looped back to the network at the
H2TU-R SmartJack module.
(Choose any one of the three commands.)
CREM 1111110 (6 in 7) Signal from customer is looped back to the
customer at the H2TU-C.
CLOC 1111100 (5 in 7) Signal from customer is looped back to the
customer at the H2TU-R.
Loopdown 11100
100
1111-1111-0010-0100
(FF24) Deactivates any of the above loopbacks.
(Choose any one of the three commands.)
For more information about the HDSL2 screens, provisioning, and
loopback testing, refer to the H2TU-C-319 List 2E technical practice,
document number 152-319-125-xx.
Front-Panel Alarm Messages
Message Description
SYSTEM ALARM MESSAGES (a)
(a) System alarm messages are listed in order of priority. ALRM displays prior to any alarm message. Pressing
the SEL button initiates an Alarm CutOff (ACO) message.
LOSW The HDSL2 loop has lost sync.
LLOS No signal is detected at the DSX-1 input to the H2TU-C.
RLOS No signal is detected at the DS1 input to the H2TU-R.
LAIS (b)
(b) Does not activate the alarm relay access pin H.
Local AIS Input Signal detected.
RAIS (b) Remote AIS Input Signal detected.
LRAI (b) An RAI condition is detected at the remote and the signal from the line unit is error-free.
RRAI (b) An RAI (yellow) alarm from the Customer Premises Equipment (CPE) with a failure from
the network.
DBER (b) A system DS1 Bit Error Rate (BER) alarm.
PRMF (b) H2TU-R Performance Report Messaging BER threshold exceeded at far end.
PRMN (b) H2TU-R Performance Report Messaging BER threshold exceeded at near end.
HBER A system HDSL2 Block Error Rate (BER) alarm.
MAL The margin on the HDSL2 loop has dropped below the threshold setting.
LA The attenuation on the HDSL2 loop has exceeded the maximum threshold value.
LINE-POWER ALARM MESSAGES (c)
(c) Line-power alarm messages display repeatedly as long as the alarm condition exists and are not included
in the priority order of the system alarm messages.
PWR FEED
SHRT A short between the Tip and Ring of the HDSL2 pair.
PWR FEED
GND The HDSL2 loop is grounded.
PWR FEED
OPEN A line-power open condition.
Network Customer
Premises
H2TU-C H2TU-R
NLOC
4 in 7 CLOC
5 in 7
CREM
6 in 7
SMJK
11000
NREM
3 in 7
Front-Panel Diagnostic Messages
Display Code Description (normal operating messages in bold)
A=xx The loop attenuation of the longest (maximum loss) span, measured in dB.
ACQ The multiplexers of the H2TU-C-319 and H2TU-R are trying to establish synchronization.
AnL The multiplexersof the two devices on Span n are trying to establish synchronization with
each other, where nis the number of the span.
ARM Armed to respond to Intelligent Repeater Loop (ILR) codes.
BAD RT? The H2TU-C is not receiving a response from the H2TU-R.
FERR A framing bit error occurred at H2TU-C DSX-1 input.
FLDL Flash download of firmware updates. (Contact Customer Service for update procedures.)
HES H2TU-C HDSL2 loop cyclical redundancy check (CRC) error.
LBPV A local bipolar violation has been received at the DSX-1 input to the H2TU-C.
M=xx Indicates the power of the received HDSL2 signal relative to noise (S/N with respect to
21.5 dB). Any value of 6 dB or greater is adequate for reliable system operation.
MNGD The H2TU-C is under control of the HMU-319 network management unit.
PWR FEED OFF HDSL2 span power is turned off.
PWR FEED ON Indicates that the HDSL2 loop is not grounded or shorted.
SIG The transceivers of the H2TU-C and H2TU-R (or the H2TU-C and first regenerator) are
trying to establish contact with each other on Span 1 of the HDSL2 loop.
SnL The transceivers of the two devices on Span nare trying to establish contact with each
other, where nis the number of the span.
Front-Panel Configuration Options Using MODE and SEL
Display Code Description (default values in bold)
EQL Sets the DSX-1 Equalizer to: 0 (0 to 133 ft.), 133 (133 to 266 ft.), 266 (266 to 399 ft.),
399 (399 to 533 ft.), 533 (533 to 655 ft.).
RLBO Sets the H2TU-R line buildout to 0 dB, -7.5 dB, or -15 dB.
LPBK Enables (ENA) or disables (DIS) SmartJack loopback commands.
FT1 Enables (ENA) or disables (DIS) system response to DDS latching loopback commands for
fractional T1 applications.
PWRF OFF = disables HDSL2 powering. ON = HDSL2 line voltage is -185 Vdc maximum.
HBER 1E-6 or 1E-7 = alarm activates when the HDSL2 BER alarm threshold exceeds 10-6 or 10-7.
NONE = prevents generation of a system alarm due to BER.
DBER Enables (ENA) or disables (DIS) fixed 24-hour DSX-1 BER alarm threshold.
LBTO Loopback timeout = NONE, 20, 60, 120 minutes.
ALM Enables (ENA) or disables (DIS) alarm indications on pin H.
DS1 DSX-1 line code = B8ZS or AMI.
CONV H2TU-R frame format conversion = OFF (framing determined by the DS1 frame formatting
option), ACON (auto detection of framing and potential frame conversion at the H2TU-R), or
FCON (auto detection of framing and forced frame format conversion at the H2TU-R).
FRMG DS1 frame formatting = AUTO (auto framing mode) or UNFR (unframed mode).
ALMP Enables system to output an alarm pattern: AIS or LOS.
BPVT Enables (ENA) or disables (DIS) Bipolar Violation Transparency.
NLBP Enables the H2TU-R to transmit either AIS or LOS towards the CI for any network loopback.
TLOS Enables (ENA) or disables (DIS) logic loopback at the H2TU-R when LOS occurs at DS1 input.
RTPV Enables (ENA) or disables (DIS) remote provisioning.
PRM OFF = no enhanced Performance Report Messaging; SPRM = Supplemental PRM;
NPRM = Network PRM; S + N = SPRM + NPRM.
NAIS If ALMP is set to AIS, this option specifies which pattern is sent to the network when a
remote LOS or AIS occurs. CI = AIS-CI sent to the network; AIS = AIS sent to the network.
CONF Updates all operating mode selections (YES or NO).
ROVR Enables (ENA) conversion of a network ESF-RAI or ESF-RAI-CI to SF-RAI or SF-RAI-CI
pattern. Disables (DIS) conversion of the RAI-CI.
RACI Enables (ENA) DS1 SF-RAI-CI (yellow alarm) signal received by the H2TU-R to be converted
to an SF-RAI-CI signal towards the network.
Disables (DIS) conversion of the DS1 SF-RAI.
ADS1 MUX = activates the DSX-1 MUX port.
AUX = Activates the auxiliary DSX-1 Port #2.
CTHR = Activates the CUt-through mode.
LATT Loop Attenuation Threshold (0 - 40 dB). Default = 35 dB.
MARG Determines the minimum allowable margin below which a system alarm can occur (4 dB) 0 dB
to -15 dB.
SPLB xxxx Configures system for generic (GNLB) or special inband loopback commands (A2LB, A3LB, A4LB).

Other manuals for HiGain H2TU-C-319 List 4E

10

Other ADC Network Hardware manuals

ADC H2TU-C-388 HiGain Original operating instructions

ADC

ADC H2TU-C-388 HiGain Original operating instructions

ADC FlexWave WMX 300 User manual

ADC

ADC FlexWave WMX 300 User manual

ADC PG-PLUS PLL-720 Instructions for use

ADC

ADC PG-PLUS PLL-720 Instructions for use

ADC H2TU-C-388 HiGain User manual

ADC

ADC H2TU-C-388 HiGain User manual

ADC High Density Position Panel LSX 288 User manual

ADC

ADC High Density Position Panel LSX 288 User manual

ADC DSX-4R (RZX3) User manual

ADC

ADC DSX-4R (RZX3) User manual

ADC HRM-238 L1 User manual

ADC

ADC HRM-238 L1 User manual

ADC Gas Discharge Tube ComProtect System manual

ADC

ADC Gas Discharge Tube ComProtect System manual

ADC PG-PLUS PLL-723 User manual

ADC

ADC PG-PLUS PLL-723 User manual

ADC Digivance User manual

ADC

ADC Digivance User manual

ADC HiGain HLU-200 User manual

ADC

ADC HiGain HLU-200 User manual

ADC HiGain HLU-C-388 List 5F Original operating instructions

ADC

ADC HiGain HLU-C-388 List 5F Original operating instructions

ADC FlexWave MMW 125 User manual

ADC

ADC FlexWave MMW 125 User manual

ADC H2TU-C-202 User manual

ADC

ADC H2TU-C-202 User manual

ADC HiGain HLU-200 User manual

ADC

ADC HiGain HLU-200 User manual

ADC H2TU-C-202 Original operating instructions

ADC

ADC H2TU-C-202 Original operating instructions

ADC FMT Drawers Featuring MicroVAM Modules User manual

ADC

ADC FMT Drawers Featuring MicroVAM Modules User manual

ADC HiGain HRE-420 User manual

ADC

ADC HiGain HRE-420 User manual

ADC Fiber Optic Panel FL2000 Series User manual

ADC

ADC Fiber Optic Panel FL2000 Series User manual

ADC DSX-1 Manual

ADC

ADC DSX-1 Manual

ADC HIGAIN H4TU-C-388 Original operating instructions

ADC

ADC HIGAIN H4TU-C-388 Original operating instructions

ADC PG-FlexPlus PG-CAB001 User manual

ADC

ADC PG-FlexPlus PG-CAB001 User manual

ADC Micro BS Plus UltraWAVE User manual

ADC

ADC Micro BS Plus UltraWAVE User manual

ADC PG-Flex FLC-706 1A Instructions for use

ADC

ADC PG-Flex FLC-706 1A Instructions for use

Popular Network Hardware manuals by other brands

Divio NRM 311 user manual

Divio

Divio NRM 311 user manual

Genexis FiberTwist XGS2410 installation guide

Genexis

Genexis FiberTwist XGS2410 installation guide

Opengear IMG4216-25 quick start guide

Opengear

Opengear IMG4216-25 quick start guide

Forcepoint V5000 Quick Start Poster

Forcepoint

Forcepoint V5000 Quick Start Poster

Fortinet FortiGate 100F Series quick start guide

Fortinet

Fortinet FortiGate 100F Series quick start guide

Cisco NCS 1004 quick start guide

Cisco

Cisco NCS 1004 quick start guide

ProSoft Technology PLX35-NB2 user manual

ProSoft Technology

ProSoft Technology PLX35-NB2 user manual

Seagate GoFlex Net quick start guide

Seagate

Seagate GoFlex Net quick start guide

Engage Black BlackDoor Duo user guide

Engage Black

Engage Black BlackDoor Duo user guide

3xLogic V250 quick start guide

3xLogic

3xLogic V250 quick start guide

technetix G.hn Powerline Wi-Fi Setup

technetix

technetix G.hn Powerline Wi-Fi Setup

Silex technology BR-330AC-LP user manual

Silex technology

Silex technology BR-330AC-LP user manual

Seagate GoFlex Desk 3TB user guide

Seagate

Seagate GoFlex Desk 3TB user guide

Optostar OP-8000-EDFA-6U Series manual

Optostar

Optostar OP-8000-EDFA-6U Series manual

NETGEAR M4100 Series ProSAFE Reference manual

NETGEAR

NETGEAR M4100 Series ProSAFE Reference manual

Alvarion BreezeMAX Extreme System manual

Alvarion

Alvarion BreezeMAX Extreme System manual

Cabletron Systems WPIM-RT1 user guide

Cabletron Systems

Cabletron Systems WPIM-RT1 user guide

AMX AXC-EM Specifications

AMX

AMX AXC-EM Specifications

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.