Benefits and Main Features:
Very easy to configure
Power Supply 12…35V DC and 8…24 V AC
Temperature range: -4 °C/+85°C (-4 °F/+185°F)
For others LoRaWAN products, see also the following links:
Converter LoRaWAN to
www.adfweb.com?Product=HD67F 1 (Mod us Master)
www.adfweb.com?Product=HD67F 2 (Mod us Slave)
www.adfweb.com?Product=HD67F 3 (Mod us TCP Master)
www.adfweb.com?Product=HD67F 4 (Mod us TCP Slave)
www.adfweb.com?Product=HD67F 5 (Serial)
www.adfweb.com?Product=HD67F15 (M-Bus)
www.adfweb.com?Product=HD67F16 (BACnet Master)
www.adfweb.com?Product=HD67F17 (BACnet Slave)
www.adfweb.com?Product=HD67F18 (Ethernet)
www.adfweb.com?Product=HD67F19 (CAN)
www.adfweb.com?Product=HD67F2 (CANopen)
www.adfweb.com?Product=HD67F21 (DeviceNet Master)
www.adfweb.com?Product=HD67F22 (DeviceNet Slave)
www.adfweb.com?Product=HD67F23 (DMX)
www.adfweb.com?Product=HD67F24 (EtherNet/IP Master)
www.adfweb.com?Product=HD67F25 (EtherNet/IP Slave)
www.adfweb.com?Product=HD67F26 (J1939)
www.adfweb.com?Product=HD67F28 (NMEA 0183)
www.adfweb.com?Product=HD67F29 (NMEA 2000)
www.adfweb.com?Product=HD67F3 (PROFIBUS Master)
www.adfweb.com?Product=HD67F31 (PROFIBUS Slave)
www.adfweb.com?Product=HD67F32 (PROFINET Master)
www.adfweb.com?Product=HD67F33 (PROFINET Slave)
www.adfweb.com?Product=HD67F34 (IEC61850 Client)
www.adfweb.com?Product=HD67F35 (IEC61850 Server)
www.adfweb.com?Product=HD67F36 (MQTT)
www.adfweb.com?Product=HD67F37 (OPC UA Client)
www.adfweb.com?Product=HD67F38 (OPC UA Server)
www.adfweb.com?Product=HD67F39 (S7comm)
www.adfweb.com?Product=HD67F4 (SNMP Manager)
www.adfweb.com?Product=HD67F41 (SNMP Agent)
User Manual

Industrial Electronic Devices
ADFweb.com S.r.l.
User Manual
KNX
/ LoRaWAN Gateway
Document code: MN67F27_ENG Revision 1. Page 2 of 3
INDEX:
Page
INDEX 2
UPDATED DOCUMENTATION 2
REVISION LIST 2
WARNING 2
TRADEMARKS 2
SECURITY ALERT 3
EXAMPLE OF CONNECTION 4
CONNECTION SCHEME 5
CHARACTERISTICS 6
CONFIGURATION 6
POWER SUPPLY 7
FUNCTION MODES 8
LEDS 9
LORAWAN 1
KNX 11
ETHERNET 12
USE OF COMPOSITOR SW67F27 13
NEW CONFIGURATION / OPEN CONFIGURATION 14
SOFTWARE OPTIONS 15
SET COMMUNICATION 17
LORAWAN ACCESS 19
KNX ACCESS 23
UPDATE DEVICE 25
MECHANICAL DIMENSIONS 27
ORDERING INFORMATIONS 28
ACCESSORIES 28
DISCLAIMER 29
OTHER REGULATIONS AND STANDARDS 29
WARRANTIES AND TECHNICAL SUPPORT 3
RETURN POLICY 3
UPDATED DOCUMENTATION:
Dear customer, we thank you for your attention and we remind you that
you need to check that the following document is:
Updated
Related to the product you own
To obtain the most recently updated document, note the “document code”
that appears at the top right-hand corner of each page of this document.
With this “Document Code” go to web page www.adfweb.com/download/
and search for the corresponding code on the page. Click on the proper
“Document Code” and download the updates.
REVISION LIST:
WARNING:
ADFweb.com reserves the right to change information in this manual about
our product without warning.
ADFweb.com is not responsible for any error this manual may contain.
TRADEMARKS:
All trademarks mentioned in this document belong to their respective
owners.
Revision
Date Author Chapter
Description
1. 3/12/2 21
Ff All First release version

Industrial Electronic Devices
ADFweb.com S.r.l.
User Manual
KNX
/ LoRaWAN Gateway
Document code: MN67F27_ENG Revision 1. Page 3 of 3
SECURITY ALERT:
G
ENERAL
I
NFORMATION
To ensure safe operation, the device must be operated according to the instructions in the manual. When using the device, legal and
safety regulation are required for each individual application. The same applies also when using accessories.
I
NTENDED
U
SE
Machines and systems must be designed so the faulty conditions do not lead to a dangerous situation for the operator (i.e.
independent limit switches, mechanical interlocks, etc.).
Q
UALIFIED
P
ERSONNEL
The device can be used only by qualified personnel, strictly in accordance with the specifications.
Qualified personnel are persons who are familiar with the installation, assembly, commissioning and operation of this equipment and
who have appropriate qualifications for their job.
R
ESIDUAL
R
ISKS
The device is state-of-the-art and is safe. The instruments can represent a potential hazard if they are inappropriately installed and
operated by untrained personnel. These instructions refer to residual risks with the following symbol:
This symbol indicates that non-observance of the safety instructions is a danger for people that could lead to serious injury or
death and / or the possibility of damage.
CE
CONFORMITY
The declaration is made by our company. You can send an email to [email protected]om or give us a call if you need it.

Industrial Electronic Devices
ADFweb.com S.r.l.
User Manual
KNX
/ LoRaWAN Gateway
Document code: MN67F27_ENG Revision 1. Page 4 of 3
EXAMPLE OF CONNECTION:

Industrial Electronic Devices
ADFweb.com S.r.l.
User Manual
KNX
/ LoRaWAN Gateway
Document code: MN67F27_ENG Revision 1. Page 5 of 3
CONNECTION SCHEME:
Figure 1: Connection scheme for HD67F27-B2- MHz

Industrial Electronic Devices
ADFweb.com S.r.l.
User Manual
KNX
/ LoRaWAN Gateway
Document code: MN67F27_ENG Revision 1. Page 6 of 3
CHARACTERISTICS:
The HD67F27-B2 is a KNX / LoRaWAN Gateway.
It allows the following characteristics:
Electrical isolation between KNX and Power Supply;
Mountable on 35mm Rail DIN;
Wide power supply input range: 12…35V DC and 8…24V AC;
Wide temperature range: -4 °C / 85°C [-4 °F / +185°F].
CONFIGURATION:
You need Compositor SW67F27 software on your PC in order to perform the following:
Define the parameter of KNX line;
Define the parameter of LoRaWAN line;
Define the list of LoRaWAN end-devices to connect;
Define the LoRaWAN messages to send/receive from each LoRaWAN end-device;
Define the KNX data points accessible by the external KNX network;
Update the device.

Industrial Electronic Devices
ADFweb.com S.r.l.
User Manual
KNX
/ LoRaWAN Gateway
Document code: MN67F27_ENG Revision 1. Page 7 of 3
POWER SUPPLY:
The devices can be powered at 8…24V AC and 12…35V DC. For more details see the two tables below.
VAC
VDC
Vmin Vmax Vmin Vmax
8V 24V 12V 35V
Consumption at 24V DC:
Device Consumption [W/VA]
HD67F27-B2-xxxMHz 3.5
HD67F27
-
B2
-
xxxMHz
Caution: Not reverse the polarity power

Industrial Electronic Devices
ADFweb.com S.r.l.
User Manual
KNX
/ LoRaWAN Gateway
Document code: MN67F27_ENG Revision 1. Page 8 of 3
FUNCTION MODES:
The device has got two functions mode depending of the position of the ‘Dip1 of Dip-Switch A’:
The first, with ‘Dip1 of Dip-Switch A’ at “OFF” position, is used for the normal working of the device.
The second, with ‘Dip1 of Dip-Switch A’ at “ON” position, is used for upload the Project and/or Firmware.
For the operations to follow for the updating, see ‘UPDATE DEVICE’ section.
According to the functioning mode, the LEDs will have specifics functions, see ‘LEDS’ section.

Industrial Electronic Devices
ADFweb.com S.r.l.
User Manual
KNX
/ LoRaWAN Gateway
Document code: MN67F27_ENG Revision 1. Page 9 of 3
LEDS:
The device has got five LEDs that are used to give information of the functioning status.
The various meanings of the LEDs are described in the table below.
LED Normal Mode Boot Mode
1: Device State (green) Blinks slowly (~1Hz) Blinks quickly: Boot state
Blinks very slowly (~0.5Hz): update in progress
2: LoRaWAN communication
(yellow) Blinks when a LoRaWAN message is received Blinks quickly: Boot state
Blinks very slowly (~0.5Hz): update in progress
3: KNX communication
(yellow) Blinks when a KNX message is received Blinks quickly: Boot state
Blinks very slowly (~0.5Hz): update in progress
4: Error state (yellow) ON: An error in the communication busses occurs
OFF: No errors are present
Blinks quickly: Boot state
Blinks very slowly (~0.5Hz): update in progress
5: Link Ethernet (Green) ON: Ethernet cable inserted
OFF: Ethernet cable not inserted
ON: Ethernet cable inserted
OFF: Ethernet cable not inserted

Industrial Electronic Devices
ADFweb.com S.r.l.
User Manual
KNX
/ LoRaWAN Gateway
Document code: MN67F27_ENG Revision 1. Page 1 of 3
LORAWAN:
The LoRaWAN® specification is a Low Power, Wide Area (LPWA) networking protocol designed to wirelessly
connect battery operated ‘things’ to the internet in regional, national or global networks, and targets key
Internet of Things (IoT) requirements such as bi-directional communication, end-to-end security, mobility
and localization services.
LoRaWAN® network architecture is deployed in a star-of-stars topology in which gateways relay messages
between end-devices and a central network server.
The wireless communication takes advantage of the Long Range characteristics of the LoRa physical layer,
allowing a single-hop link between the end-device and one or many gateways. All modes are capable of bi-
directional communication, and there is support for multicast addressing groups to make efficient use of
spectrum during tasks such as Firmware Over-The-Air (FOTA) upgrades or other mass distribution
messages.
The converters support all the standard datarates and they work both on public and private networks.

Industrial Electronic Devices
ADFweb.com S.r.l.
User Manual
KNX
/ LoRaWAN Gateway
Document code: MN67F27_ENG Revision 1. Page 11 of 3
KNX:
KNX is the standard that allows the automated and decentralized management of the technologic plans of
a big typology of structures: commercial buildings, factories, houses, public locals, schools and so on.
KNX can be used in all the applications and functions for the building automations: from lighting to control
dampers, to the security, to the heating monitoring, to the conditioning, to the hydric control and alarms,
to energy management and so on.
Characteristics Description TP1-256
Medium Shielded Twisted Pair
Topology Linear, Star, Tree or mixed
Baudrate 96 bps
Device supplying Normal: bus powered devices
Optional: remote powered devices
Device power consumption 3 mA- 12 mA
Power Supply Unit (PSU) DC 3 V
Number of PSU’s per physical
Segment Max. 2
Number of connectable devices
per physical Segment Max. 256
Number of addressable devices
per physical Segment Max. 255
Total cable length per physical
Segment Max. 1 m
Distance between two devices Max. 7 m
(*) Taken from KNX specifications

Industrial Electronic Devices
ADFweb.com S.r.l.
User Manual
KNX
/ LoRaWAN Gateway
Document code: MN67F27_ENG Revision 1. Page 12 of 3
ETHERNET:
Ethernet port is used for programming the device.
Ethernet connection must be made using Connector3 of HD67F27-B2 with at least a Category 5E cable. The maximum length of the cable
should not exceed 1 m. The cable has to conform to the T568 norms relative to connections in cat.5 up to 1 Mbps. To connect the device
to an Hub/Switch is recommended the use of a straight cable, to connect the device to a PC is recommended the use of a cross cable.

Industrial Electronic Devices
ADFweb.com S.r.l.
User Manual
KNX
/ LoRaWAN Gateway
Document code: MN67F27_ENG Revision 1. Page 13 of 3
USE OF COMPOSITOR SW67F17:
To configure the Converter, use the available software that runs with Windows called SW67F27. It is downloadable on the site
www.adfweb.com and its operation is described in this document. The software works with MS Windows (XP, Vista, Seven, 8, 1 , 11;
32/64bit).
When launching the SW67F27, the window below appears (Fig. 2).
Note:
It is necessary to have installed .Net Framework 4.
Figure 2: Main window for SW67F27

Industrial Electronic Devices
ADFweb.com S.r.l.
User Manual
KNX
/ LoRaWAN Gateway
Document code: MN67F27_ENG Revision 1. Page 14 of 3
NEW CONFIGURATION / OPEN CONFIGURATION:
The “New Configuration” button creates the folder which contains the entire device’s configuration.
A device’s configuration can also be imported or exported:
To clone the configurations of a Programmable “KNX / LoRaWAN Gateway - Converter”
in order to configure another device in the same manner, it is necessary to maintain
the folder and all its contents;
To clone a project in order to obtain a different version of the project, it is sufficient to
duplicate the project folder with another name and open the new folder with the
button “Open Configuration”.

Industrial Electronic Devices
ADFweb.com S.r.l.
User Manual
KNX
/ LoRaWAN Gateway
Document code: MN67F27_ENG Revision 1. Page 15 of 3
SOFTWARE OPTIONS:
By pressing the “Settings” ( ) button there is the possibility to change the language of the software and check the updatings for the
compositor.
In the section “Language” it is possible to change the language of the
software.
In the section “Connection Options”, it is possible to check if there are some
updatings of the software compositor in ADFweb.com website.
Checking the option “Check Software Update at Start of Program”, the
SW67F27 check automatically if there are updatings when it is launched.

Industrial Electronic Devices
ADFweb.com S.r.l.
User Manual
KNX
/ LoRaWAN Gateway
Document code: MN67F27_ENG Revision 1. Page 16 of 3
In the section “Software Settings”, it is possible to enable/disable some
keyboard’s commands for an easier navigation inside the tables contained in
the different sections of the software.

Industrial Electronic Devices
ADFweb.com S.r.l.
User Manual
KNX
/ LoRaWAN Gateway
Document code: MN67F27_ENG Revision 1. Page 17 of 3
SET COMMUNICATION:
By Pressing the “Set Communication” button from the main window for SW67F27 (Fig. 2)
the window “Set Communication” appears (Fig. 3).
The means of the fields for the “Ethernet Connection” section are:
In the field “Device Name (Hostname)” the Hostname to assign to the converter is
defined;
If the field “O tain an IP Address Automatically (DHCP for Ca le Connection)”
is checked, DHCP for LAN connection is enabled;
If the field “O tain an IP Address Automatically (DHCP for Wi-Fi Connection)”
is checked, DHCP for Wi-Fi connection is enabled;
If the field “Ena le DNS” is checked, DNS protocol is enabled;
In the field “Primary DNS” the IP Address of the primary DNS server is defined;
In the field “Secondary DNS” the IP Address of the secondary DNS server is
defined.
The means of the fields for the “LoRaWAN” section are:
In the field “RF Band” the wireless band used for LoRaWAN communication is
defined;
In the field “Network Type” the type of LoRaWAN network is defined;
In the field “Diagnostic Position” it is possible to define an offset into the internal
memory array where the status of the LoRaWAN end devices configured is saved.
The diagnostic is made bit to bit, so each bit will represent a status of a single end
device:
o1 End device connected;
o End device not connected.
The bits’ order will be the same of the end devices’ definition inside the LoRaWAN
Access section;
In the field “RX2 Datarate” the data rate on RX2 window is defined. Figure 3: “Set Communication” window

Industrial Electronic Devices
ADFweb.com S.r.l.
User Manual
KNX
/ LoRaWAN Gateway
Document code: MN67F27_ENG Revision 1. Page 18 of 3
The means of the fields for “KNX” are:
In the field “Type” the type of KNX is defined (fixd to ‘KNX TP’);
In the field “ID Device” the ID of the KNX side of the converter is defined.
The means of the fields for the “Ethernet” section are:
In the fields “IP Address” the IP address for Ethernet side of the converter is defined;
In the fields “Su Net Mask” the SubNet Mask for Ethernet side of the converter is defined;
In the fields “Gateway” the default gateway of the net is defined. This feature can be enabled or disabled pressing the Check Box
field. This feature is used for going out of the net;

Industrial Electronic Devices
ADFweb.com S.r.l.
User Manual
KNX
/ LoRaWAN Gateway
Document code: MN67F27_ENG Revision 1. Page 19 of 3
Figure 4a: “LoRAWAN Gatew
ay Set Access” window
LORAWAN ACCESS:
By Pressing the “LoRaWAN Access” button from the main window for SW67F27 (Fig. 2) the window “LoRaWAN Gateway Set Access”
appears (Fig. 4). This section is used to define the LoRAWAN end devices that will connect to the converter and the list of LoRaWAN
messages to read (Uplink Rules) and write (Downlink Rules) from each one.

Industrial Electronic Devices
ADFweb.com S.r.l.
User Manual
KNX
/ LoRaWAN Gateway
Document code: MN67F27_ENG Revision 1. Page 2 of 3
In the “LoRaWAN Gateway Devices List”, the list of LoraWAN end devices to connect is defined. The means of the fields for configuration
are:
If the field “Ena le” is checked, the LoRaWAN end device is enabled;
In the field “Device EUI” the Device EUI for the LoRaWAN device is defined;
In the field “Join EUI” the Join EUI for the LoRaWAN device is defined;
In the field “Device Name” the name of the LoRaWAN device is defined;
In the field “Activation Method” the activation method for LoRaWAN device is defined;
In the field “Network Session Key” the Network session key for LoRaWAN connection is defined;
In the field “Application Session Key” the Application session key for LoRaWAN connection is defined;
In the field “Application Key” the Application key for LoRaWAN connection is defined;
In the field “Device Address” the address of the LoRaWAN device is defined;
In the field “Class” the Class of the LoRaWAN device is defined;
In the field “Diag. TimeOut” the timeout in ms for LoRaWAN communication is defined. If the LoRaWAN messages are received for
this timeout, the correspondent bit for the diagnostic of KNX side is set to 1;
In the field “RX2 Datarate” the datarate used into the RX2 window is defined (optional).
In the field “Mnemonic” a description of the LoRaWAN device is defined.
Note:
It is recommended to set the “Diag. Timeout” with a higher time than the cyclic delay used by the LoRaWAN device to send data.
Table of contents
Other ADF Web Gateway manuals