ADF Web HD67154-A1 User manual

Industrial Electronic Devices
ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com hone +39.0438.30.91.31
User Manual
Ethernet
from/
to
DeviceNet
Master
Document code: MN67154_ENG Revision 1. Page 1 of 14
User Manual
Revision 1.
English
Gateway / Bridge
Ethernet from/to DeviceNet Master
(Order Code: HD67154-A1 – HD67154-B2)
for Website information:
www.adfweb.com?Product=HD67154
for Price information:
www.adfweb.com?Price=HD67154-A1
www.adfweb.com?Price=HD67154-B2
Benefits and Main Features:
Very easy to configure
Low cost
Rail mountable
Wide supply input range
Galvanic isolation between two buses
Industrial temperature range:
-3 °C / 7 °C (-22°F / 158°F)
For other DeviceNet products see also the following link:
DeviceNet Slave from/to
www.adfweb.com?Product=HD67 43 (Ethernet
www.adfweb.com?Product=HD67 58 (M-Bus
www.adfweb.com?Product=HD67134 (CANopen SDO Client
www.adfweb.com?Product=HD67136 (CANopen SDO Server
www.adfweb.com?Product=HD67137 (J1939
www.adfweb.com?Product=HD67138 (Modbus Slave
www.adfweb.com?Product=HD67139 (Modbus TCP Client
www.adfweb.com?Product=HD6714 (Modbus TCP Server
www.adfweb.com?Product=HD67141 (Modbus Master
www.adfweb.com?Product=HD67235 (CAN
www.adfweb.com?Product=HD67554 (PROFIBUS
DeviceNet Master from/to
www.adfweb.com?Product=HD67151 (Modbus Slave
www.adfweb.com?Product=HD67152 (Modbus TCP Server
www.adfweb.com?Product=HD67153 (CANopen
www.adfweb.com?Product=HD67555 (PROFIBUS
Do you have an your customer protocol? See the following link:
www.adfweb.com?Product=HD67 3
Do you need to choose a device? do you want help?
Ask it to the following link:
www.adfweb.com?Cmd=helpme
HD6715
4
-
A1
HD6715
4
-
B2

Industrial Electronic Devices
ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com hone +39.0438.30.91.31
User Manual
Ethernet
from/
to
DeviceNet
Master
Document code: MN67154_ENG Revision 1. Page 2 of 14
INDEX:
Page
INDEX 2
UPDATED DOCUMENTATION 2
REVISION LIST 2
WARNING 2
TRADEMARKS 2
CONNECTION SCHEME 3
CHARACTERISTICS 5
CONFIGURATION 5
POWER SUPPLY 5
USE OF COMPOSITOR SW67154 6
NEW PROJECT / OPEN PROJECT 6
SET COMMUNICATION 7
DEVICENET NETWORK 8
UPDATE DEVICE 9
CHARACTERISTICS OF THE CABLES 1
ETHERNET PROTOCOL 11
MECHANICAL DIMENSIONS 13
ORDER CODE 13
ACCESSORIES 13
WARRANTIES AND TECHNICAL SUPPORT 14
RETURN POLICY 14
PRODUCTS AND RELATED DOCUMENTS 14
UPDATED DOCUMENTATION:
Dear customer, we thank you for your attention and we remind you that you
need to check that the following document is:
Updated
Related to the product you own.
To obtain the most recently updated document, note the “document code” that
appears at the top right-hand corner of each page of this document.
With this “Document Code” go to web page www.adfweb.com/download/ and
search for the corresponding code on the page. Click on the proper “Document
Code” and download the update.
To obtain the updated documentation for the product that you own, note the
“Document Code” (Abbreviated written "Doc. Code" on the label on the product)
and download the updated from our web site www.adfweb.com/download/
REVISION LIST:
Revision
Date Author
Chapter Description
1. 23/ 4/2 1 Fl All First release version
WARNING:
ADFweb.com reserves the right to change information in this manual about our
product without warning.
ADFweb.com is not responsible for any error this manual may contain.
TRADEMARKS:
All trademarks mentioned in this document belong to their respective owners.

Industrial Electronic Devices
ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com hone +39.0438.30.91.31
User Manual
Ethernet
from/
to
DeviceNet
Master
Document code: MN67154_ENG Revision 1. Page 3 of 14
CONNECTION SCHEME:
Figure 1: Connection scheme for HD67154-A1

Industrial Electronic Devices
ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com hone +39.0438.30.91.31
User Manual
Ethernet
from/
to
DeviceNet
Master
Document code: MN67154_ENG Revision 1. Page 4 of 14
Figure 2: Connection scheme for HD67154-B2

Industrial Electronic Devices
ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com hone +39.0438.30.91.31
User Manual
Ethernet
from/
to
DeviceNet
Master
Document code: MN67154_ENG Revision 1. Page 5 of 14
CHARACTERISTICS:
The Ethernet from/to DeviceNet Master Gateway allows the following characteristics:
Two-directional information between Ethernet and DeviceNet bus;
Electrical isolation between two buses;
Power supply of 8…19 VAC 4VA or 8…35 VDC 4W;
35mm Rail DIN mounting;
Temperature range -3 °C to 7 °C.
CONFIGURATION:
You need Compositor SW67154 software on your PC in order to perform the following:
Define the parameters of Ethernet;
Define the parameters of DeviceNet;
Define the DeviceNet Slave devices ;
Update the Firmware and/or the Project.
POWER SUPPLY:
Caution: Not reverse the polarity power.
Recommended Power Supply
VDC VAC
24 12
VDC VAC
Vmin Vmax Vmin Vmax
8v 35v 8v 19v

Industrial Electronic Devices
ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com hone +39.0438.30.91.31
User Manual
Ethernet
from/
to
DeviceNet
Master
Document code: MN67154_ENG Revision 1. Page 6 of 14
USE OF COMPOSITOR SW67154:
To configure the Gateway, use the available software that runs
with Windows, called SW67154. It is downloadable on the site
www.adfweb.com and its operation is described in this document.
When launching the SW67154 the right window appears (Fig. 3).
NEW PROJECT / OPEN PROJECT:
The “New Project” button creates the folder which contains the entire device configuration.
A device configuration can also be imported or exported:
To clone the configurations of a Programmable Ethernet to DeviceNet Master Gateway in order to configure another device in the
same manner, it is necessary to maintain the folder and all its contents;
To clone a project in order to obtain a different version of the project, it is sufficient to duplicate the project folder with another name
and open the new folder with the button “Open Project”.
Figure 3
: Main window for SW67
15
4

Industrial Electronic Devices
ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com hone +39.0438.30.91.31
User Manual
Ethernet
from/
to
DeviceNet
Master
Document code: MN67154_ENG Revision 1. Page 7 of 14
SET COMMUNICATION:
This section defines the fundamental communication parameters of two buses Ethernet and
DeviceNet.
By pressing the “Set Communication” button from the main window for SW67154 (Fig. 3) the “SET
COMMUNICATION” window appears (Fig. 4).
This window is divided in two sections, one for the DeviceNet and the other for the Ethernet.
The means of the fields for the “DeviceNet Master” section are:
In the “ID Dev.” field the Gateway address of the DeviceNet is defined.
In the “Baud rate” field the DeviceNet baud rate is defined.
The means of the fields for “Ethernet” are:
In the field “IP Address” insert the IP address;
In the field “Subnet Mask” insert the Subnet Mask;
If the field “Gateway” is checked in the fields under it is possible to insert the IP address
used for going out to the net;
In the field “Port” insert the number of the port;
If the field “TCP” is checked, the Ethernet protocol used is the TCP, otherwise if the field
“UDP” is checked the Ethernet protocol used is the UDP.
Figure 4
:
“Set Communication”
window

Industrial Electronic Devices
ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com hone +39.0438.30.91.31
User Manual
Ethernet
from/
to
DeviceNet
Master
Document code: MN67154_ENG Revision 1. Page 8 of 14
DEVICENET NETWORK:
By pressing the “DeviceNet Network” button from the main window for SW67154 (Fig. 3) the window “DeviceNet Network” appears (Fig. 5).
Here it is possible to define the Slaves DeviceNet Devices with their ID, number of Input and number of Output bytes.
The data of the columns have the following meanings:
In the field “ID” the ID of a slave DeviceNet device is defined;
In the field “N BYTE IN” the number of input byte of the slave DeviceNet is defined;
In the field “N BYTE OUT” the number of output byte of the slave DeviceNet is defined;
In the field “Mnemonic” is possible to insert a description. It isn’t necessary compiling this field, is only a label.
Figure 5: “Set Access
” window

Industrial Electronic Devices
ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com hone +39.0438.30.91.31
User Manual
Ethernet
from/
to
DeviceNet
Master
Document code: MN67154_ENG Revision 1. Page 9 of 14
UPDATE DEVICE:
Section “Update Firmware” (Fig. 6):
In order to load the parameters or update the firmware in the device, follow these instructions:
Turn off the Device;
Connect the Null Modem Cable form your PC to the Gateway;
Insert the Boot Jumper (For more info see Fig. 1 or Fig. 2);
Select the COM port and press the “Connect” button;
Turn on the device;
Check the BOOT Led. It must blink quickly (For more info see Fig. 1 or Fig. 2);
Press the “Next” button;
Select which operations you want to do.
Press the “Execute update firmware” button to start the upload;
When all the operations are “OK” turn off the device;
Disconnect the Boot jumper;
Disconnect the RS232 Cable;
Turn on the device.
At this point the configuration/firmware on the device is correctly update.
Note:
When you install a new version of the software it is better if the first time
you do the update of the Firmware in the HD67154-xx device.
Warning:
If the Fig. 7 appears when you try to do the Update before require
assistance try these points:
Check if the serial COM port selected is the correct one;
Check if the serial is connected between the PC and the device;
Try to repeat the operations for the updating;
If you are using a dongle try with a native COM port or change the dongle;
Try with another PC.
Figure 7: “ rotection” window
Figure
6
:
“
Update Device
” windows

Industrial Electronic Devices
ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com hone +39.0438.30.91.31
User Manual
Ethernet
from/
to
DeviceNet
Master
Document code: MN67154_ENG Revision 1. Page 1 of 14
CHARACTERISTICS OF THE CABLES:
E
THERNET
:
The connection at Ethernet socket must be with a Ethernet Cable with a RJ45 plug.
RS
232:
The connection from RS232 socket to a serial port (example one from a personal computer) must be made with a NULL MODEM cable (a serial
cable where the pins 2 and 3 are crossed).
It is recommended that the RS232C Cable not exceed 15 meters.
Figure 8: Null modem cabling

Industrial Electronic Devices
ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com hone +39.0438.30.91.31
User Manual
Ethernet
from/
to
DeviceNet
Master
Document code: MN67154_ENG Revision 1. Page 11 of 14
ETHERNET PROTOCOL:
This protocol has got two functions for write and read frames. These routines can use both the UDP protocol and the TCP by setting the
parameter wanted with the Compositor SW67154.
R
EAD
F
UNCTION
:
The request include the following byte:
Byte Number Description
1 Type of Operation (Read = 1)
2 ID of the Slave DeviceNet to Read
3 Starting Address Hi
4 Starting Address Lo
5 Number of Byte to Read Hi
6 Number of Byte to Read Lo
The response includes the following byte:
Byte Number Description
1 Read Error Byte
2÷n+1 Data Read
n=Number of Byte to Read
The “Read Error Byte” (Byte 1) can have three values:
•x : No error;
•x 1: Starting Address doesn’t exist;
•x 2: Too many Data to Read.
If the “Read Error Byte” is 1 or 2 there aren’t the data after the first byte (frame has got only one byte).
Example:
Slave DeviceNet: 13 ; DeviceNet OUT: 1 ; DeviceNet OUT Array ( ...9): $46 $47 $48 $49 $50 $51 $52 $53 $54 $55
R
EQ
: $ 1 $ D $ $ 4 $ $ 6
R
ES
: $ $50 $51 $52 $53 $54 $55
In blue you can see the requested data. There is an offset so first byte of the DeviceNet array is the and not 1.

Industrial Electronic Devices
ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com hone +39.0438.30.91.31
User Manual
Ethernet
from/
to
DeviceNet
Master
Document code: MN67154_ENG Revision 1. Page 12 of 14
W
RITE
F
UNCTION
:
The request include the following byte:
Byte Number Description
1 Type of Operation (Write = 2)
2 ID of the Slave DeviceNet to Write
3 Starting Address Hi
4 Starting Address Lo
5 Number of Byte to Write Hi
6 Number of Byte to Write Lo
7÷n+6 Data Write
n=Number of Byte to Write
The response includes the following byte:
Byte Number Description
1 Write Status Byte
The “Write Status Byte” (Byte 1) can have three values:
•x : No error, operation completed with success;
•x 1: Starting Address doesn’t exist;
•x 2: Too many Data to Write.
Example:
Slave DeviceNet: 13 ; DeviceNet IN: 2 ;
DeviceNet IN Array ( ...19): $65 $64 $63 $62 $61 $6 $59 $58 $57 $56 $55 $54 $53 $52 $51 $5 $49 $48 $47 $46
R
EQ
: $ 1 $ E $ $ 2 $ $ 5 $3 $31 $32 $33 $34
R
ES
: $
After that the New DeviceNet IN Array is: $65 $64 $30 $31 $32 $33 $34 $58 $57 $56 $55 $54 $53 $52 $51 $5 $49 $48 $47 $46
In blue you can find the data changed.

Industrial Electronic Devices
ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com hone +39.0438.30.91.31
User Manual
Ethernet
from/
to
DeviceNet
Master
Document code: MN67154_ENG Revision 1. Page 13 of 14
MECHANICAL DIMENSIONS:
ORDER CODE:
Order Code: HD67154-A1 - Gateway – Ethernet from/to DeviceNet Master
Order Code: HD67154-B2 - Gateway – Ethernet from/to DeviceNet Master
ACCESSORIES:
Order Code: AC34107 - Null Modem Cable Fem/Fem DSub 9 Pin 1,5 m
Order Code: AC34114 - Null Modem Cable Fem/Fem DSub 9 Pin 5 m
Figure 11: Mechanical dimensions scheme for HD67154-A1
Figure
1
2
: Mechanical dimensions schem
e for H
D6715
4
-
B2

Industrial Electronic Devices
ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com hone +39.0438.30.91.31
User Manual
Ethernet
from/
to
DeviceNet
Master
Document code: MN67154_ENG Revision 1. Page 14 of 14
WARRANTIES AND TECHNICAL SUPPORT:
For fast and easy technical support for your ADFweb.com srl products, consult our internet support at www.adfweb.com.
Otherwise contact us at the address supp[email protected].
RETURN POLICY:
If while using your product you have any problem and you wish to exchange or repair it, please do the following:
1) Obtain a Product Return Number (PRN) from our internet support at www.adfweb.com. Together with the request, you need to provide detailed information
about the problem.
2) Send the product to the address provided with the PRN, having prepaid the shipping costs (shipment costs billed to us will not be accepted).
3) If the product is within the warranty of twelve months, it will be repaired or exchanged and returned within three weeks. If the product is no longer under
warranty, you will receive a repair estimate.
PRODUCTS AND RELATED DOCUMENTS:
Part Description URL
HD67117 CAN Repeater/Isolator www.adfweb.com?Product=HD67117
HD67216 Can Analyzer www.adfweb.com?Product=HD67216
HD67221 Translate CAN bus Gateway www.adfweb.com?Product=HD67221
This manual suits for next models
1
Table of contents
Other ADF Web Gateway manuals
Popular Gateway manuals by other brands

Milesight
Milesight UR32L quick guide

RTA
RTA 460ETCMS-N700 Product user guide

Zennio
Zennio KLIC-DD v3 user manual

Sierra Wireless
Sierra Wireless AirLink Raven-E 1 series user guide

Fanstel
Fanstel OpenSource LEW840X Series operating instructions

Bosch
Bosch Rexroth IndraControl SafeLogic... operating instructions