ADF Web HD67F38-B2 Series User manual

Industrial Electronic Devices
ADFweb.com S.r.l.
User Manual
OPC UA Server / LoRaWAN Gateway
Document code: MN67F38_ENG Revision 1 000 Page 1 of 31
User Manual
Revision 1 000
English
OPC UA Server / LoRaWAN Gateway -
Converter
(Order Code: HD67F38-B2-xxxMHz)
For Website information:
www adfweb com?Product=HD67F38-B2
For Price information:
www adfweb com?Price=HD67F38-B2-xxxMHz
Benefits and Main Features
Very easy to configure
Power Supply 12…35V DC and 8…24 V AC
Temperature range: -40°C/+85°C (-40°F/+185°F)
For others LoRaWAN products, see also the following links:
Converter LoRaWAN to
www adfweb com?Product=HD67F01 (Modbus Master)
www adfweb com?Product=HD67F02 (Modbus Slave)
www adfweb com/?Product=HD67F03 (Modbus TCP Master)
www adfweb com/?Product=HD67F04 (Modbus TCP Slave)
www adfweb com?Product=HD67F05 (Serial)
www adfweb com?Product=HD67F15 (M-Bus)
www adfweb com?Product=HD67F16 (BACnet Master)
www adfweb com?Product=HD67F17 (BACnet Slave)
www adfweb com?Product=HD67F18 (Ethernet)
www adfweb com?Product=HD67F19 (CAN)
www adfweb com?Product=HD67F20 (CANopen)
www adfweb com?Product=HD67F21 (DeviceNet Master)
www adfweb com?Product=HD67F22 (DeviceNet Slave)
www adfweb com?Product=HD67F23 (DMX)
www adfweb com?Product=HD67F24 (EtherNet/IP Master)
www adfweb com?Product=HD67F25 (EtherNet/IP Slave)
www adfweb com?Product=HD67F26 (J1939)
www adfweb com?Product=HD67F27 (KNX)
www adfweb com?Product=HD67F28 (NMEA 0183)
www adfweb com?Product=HD67F29 (NMEA 2000)
www adfweb com?Product=HD67F30 (PROFIBUS Master)
www adfweb com?Product=HD67F31 (PROFIBUS Slave)
www adfweb com?Product=HD67F32 (PROFINET Master)
www adfweb com?Product=HD67F33 (PROFINET Slave)
www adfweb com?Product=HD67F34 (IEC61850 Client)
www adfweb com?Product=HD67F35 (IEC61850 Server)
www adfweb com?Product=HD67F36 (MQTT)
www adfweb com?Product=HD67F37 (OPC UA Client)
www adfweb com?Product=HD67F39 (S7comm)
www adfweb com?Product=HD67F40 (SNMP Manager)
www adfweb com?Product=HD67F41 (SNMP Agent)
User Manual

Industrial Electronic Devices
ADFweb.com S.r.l.
User Manual
OPC UA Server / LoRaWAN Gateway
Document code: MN67F38_ENG Revision 1 000 Page 2 of 31
INDEX
Page
INDEX 2
UPDATED DOCUMENTATION 2
REVISION LIST 2
WARNING 2
TRADEMARKS 2
SECURITY ALERT 3
EXAMPLE OF CONNECTION 4
CONNECTION SCHEME 5
CHARACTERISTICS 6
CONFIGURATION 6
POWER SUPPLY 7
FUNCTION MODES 8
LEDS 9
LORAWAN 10
ETHERNET 11
USE OF COMPOSITOR SW67F38 12
NEW CONFIGURATION / OPEN CONFIGURATION 13
SOFTWARE OPTIONS 14
SET COMMUNICATION 16
LORAWAN ACCESS 21
OPC UA ACCESS 25
UPDATE DEVICE 26
MECHANICAL DIMENSIONS 28
ORDERING INFORMATIONS 29
ACCESSORIES 29
DISCLAIMER 30
OTHER REGULATIONS AND STANDARDS 30
WARRANTIES AND TECHNICAL SUPPORT 31
RETURN POLICY 31
UPDATED DOCUMENTATION
Dear customer, we thank you for your attention and we remind you that
you need to check that the following document is:
Updated
Related to the product you own
To obtain the most recently updated document, note the “document code”
that appears at the top right-hand corner of each page of this document
With this “Document Code” go to web page www adfweb com/download/
and search for the corresponding code on the page Click on the proper
“Document Code” and download the updates
REVISION LIST
WARNING
ADFweb com reserves the right to change information in this manual about
our product without warning
ADFweb com is not responsible for any error this manual may contain
TRADEMARKS
All trademarks mentioned in this document belong to their respective
owners
Revision
Date Author Chapter
Description
1 000 03/2/2023 Ln All First release version

Industrial Electronic Devices
ADFweb.com S.r.l.
User Manual
OPC UA Server / LoRaWAN Gateway
Document code: MN67F38_ENG Revision 1 000 Page 3 of 31
SECURITY ALERT
G
ENERAL
I
NFORMATION
To ensure safe operation, the device must be operated according to the instructions in the manual When using the device, legal and
safety regulation are required for each individual application The same applies also when using accessories
I
NTENDED
U
SE
Machines and systems must be designed so the faulty conditions do not lead to a dangerous situation for the operator (i e
independent limit switches, mechanical interlocks, etc )
Q
UALIFIED
P
ERSONNEL
The device can be used only by qualified personnel, strictly in accordance with the specifications
Qualified personnel are persons who are familiar with the installation, assembly, commissioning and operation of this equipment and
who have appropriate qualifications for their job
R
ESIDUAL
R
ISKS
The device is state-of-the-art and is safe The instruments can represent a potential hazard if they are inappropriately installed and
operated by untrained personnel These instructions refer to residual risks with the following symbol:
This symbol indicates that non-observance of the safety instructions is a danger for people that could lead to serious injury or
death and / or the possibility of damage
CE
CONFORMITY
The declaration is made by our company You can send an email to support@adfweb com or give us a call if you need it

Industrial Electronic Devices
ADFweb.com S.r.l.
User Manual
OPC UA Server / LoRaWAN Gateway
Document code: MN67F38_ENG Revision 1 000 Page 4 of 31
EXAMPLE OF CONNECTION

Industrial Electronic Devices
ADFweb.com S.r.l.
User Manual
OPC UA Server / LoRaWAN Gateway
Document code: MN67F38_ENG Revision 1 000 Page 5 of 31
CONNECTION SCHEME
Figure 1: Connection scheme for HD67F38- 2-xxxMHz

Industrial Electronic Devices
ADFweb.com S.r.l.
User Manual
OPC UA Server / LoRaWAN Gateway
Document code: MN67F38_ENG Revision 1 000 Page 6 of 31
CHARACTERISTICS
The HD67F38-B2 is a OPC UA Server / LoRaWAN Gateway
It allows the following characteristics:
Electrical isolation between Ethernet and Power Supply;
Mountable on 35mm Rail DIN;
Wide power supply input range: 12…35V DC and 8…24V AC;
Wide temperature range: -40°C / 85°C [-40°F / +185°F]
CONFIGURATION
You need Compositor SW67F38 software on your PC in order to perform the following:
Define the parameter of OPC UA line;
Define the parameter of LoRaWAN line;
Define the list of LoRaWAN end-devices to connect;
Define the LoRaWAN messages to send/receive from each LoRaWAN end-device;
Define the OPA UA variables accessible by the OPC UA Client;
Update the device

Industrial Electronic Devices
ADFweb.com S.r.l.
User Manual
OPC UA Server / LoRaWAN Gateway
Document code: MN67F38_ENG Revision 1 000 Page 7 of 31
POWER SUPPLY
The devices can be powered at 8…24V AC and 12…35V DC For more details see the two tables below
VAC
VDC
Vmin Vmax Vmin Vmax
8V 24V 12V 35V
Consumption at 24V DC:
Device Consumption [W/VA]
HD67F38-B2-xxxMHz 3 5
HD67F38
-
B2
-
xxxMHz
Caution Not reverse the polarity power

Industrial Electronic Devices
ADFweb.com S.r.l.
User Manual
OPC UA Server / LoRaWAN Gateway
Document code: MN67F38_ENG Revision 1 000 Page 8 of 31
FUNCTION MODES
The device has got two functions mode depending of the position of the ‘Dip1 of Dip-Switch A’:
The first, with ‘Dip1 of Dip-Switch A’ at “OFF” position, is used for the normal working of the device
The second, with ‘Dip1 of Dip-Switch A’ at “ON” position, is used for upload the Project and/or Firmware
For the operations to follow for the updating, see ‘UPDATE DEVICE’ section
According to the functioning mode, the LEDs will have specifics functions, see ‘LEDS’ section

Industrial Electronic Devices
ADFweb.com S.r.l.
User Manual
OPC UA Server / LoRaWAN Gateway
Document code: MN67F38_ENG Revision 1 000 Page 9 of 31
LEDS
The device has got five LEDs that are used to give information of the functioning status
The various meanings of the LEDs are described in the table below
LED Normal Mode Boot Mode
1: Device State (green) Blinks slowly (~1Hz) Blinks quickly Boot state
Blinks very slowly (~0.5Hz) update in progress
2: LoRaWAN communication
(yellow) Blinks when a LoRaWAN message is received Blinks quickly Boot state
Blinks very slowly (~0.5Hz) update in progress
3: OPC UA communication
(yellow) Blinks when a OPC UA request is received Blinks quickly Boot state
Blinks very slowly (~0.5Hz) update in progress
4: Not used OFF Blinks quickly Boot state
Blinks very slowly (~0.5Hz) update in progress
5: Link Ethernet (Green) ON Ethernet cable inserted
OFF Ethernet cable not inserted
ON Ethernet cable inserted
OFF Ethernet cable not inserted

Industrial Electronic Devices
ADFweb.com S.r.l.
User Manual
OPC UA Server / LoRaWAN Gateway
Document code: MN67F38_ENG Revision 1 000 Page 10 of 31
LORAWAN
The LoRaWAN® specification is a Low Power, Wide Area (LPWA) networking protocol designed to wirelessly
connect battery operated ‘things’ to the internet in regional, national or global networks, and targets key
Internet of Things (IoT) requirements such as bi-directional communication, end-to-end security, mobility and
localization services
LoRaWAN® network architecture is deployed in a star-of-stars topology in which gateways relay messages
between end-devices and a central network server
The wireless communication takes advantage of the Long Range characteristics of the LoRa physical layer,
allowing a single-hop link between the end-device and one or many gateways All modes are capable of bi-
directional communication, and there is support for multicast addressing groups to make efficient use of
spectrum during tasks such as Firmware Over-The-Air (FOTA) upgrades or other mass distribution messages
The converters support all the standard datarates and they work both on public and private networks

Industrial Electronic Devices
ADFweb.com S.r.l.
User Manual
OPC UA Server / LoRaWAN Gateway
Document code: MN67F38_ENG Revision 1 000 Page 11 of 31
ETHERNET
The Ethernet port is used for OPC UA communication and for programming the device
The Ethernet connection must be made using Connector3 of HD67F38-B2 with at least a Category 5E cable The maximum length of the
cable should not exceed 100m The cable has to conform to the T568 norms relative to connections in cat 5 up to 100 Mbps To connect the
device to an Hub/Switch is recommended the use of a straight cable, to connect the device to a PC is recommended the use of a cross cable

Industrial Electronic Devices
ADFweb.com S.r.l.
User Manual
OPC UA Server / LoRaWAN Gateway
Document code: MN67F38_ENG Revision 1 000 Page 12 of 31
USE OF COMPOSITOR SW67F38
To configure the Converter, use the available software that runs with Windows called SW67F38 It is downloadable on the site
www adfweb com and its operation is described in this document The software works with MS Windows (XP, Vista, Seven, 8, 10, 11;
32/64bit)
When launching the SW67F38, the window below appears (Fig 2)
Note:
It is necessary to have installed Net Framework 4
Figure 2: Main window for SW67F38

Industrial Electronic Devices
ADFweb.com S.r.l.
User Manual
OPC UA Server / LoRaWAN Gateway
Document code: MN67F38_ENG Revision 1 000 Page 13 of 31
NEW CONFIGURATION / OPEN CONFIGURATION
The “New Configuration” button creates the folder which contains the entire device’s configuration
A device’s configuration can also be imported or exported:
To clone the configurations of a Programmable “OPC UA Server / LoRaWAN Gateway -
Converter” in order to configure another device in the same manner, it is necessary to
maintain the folder and all its contents;
To clone a project in order to obtain a different version of the project, it is sufficient to
duplicate the project folder with another name and open the new folder with the button
“Open Configuration”

Industrial Electronic Devices
ADFweb.com S.r.l.
User Manual
OPC UA Server / LoRaWAN Gateway
Document code: MN67F38_ENG Revision 1 000 Page 14 of 31
SOFTWARE OPTIONS
By pressing the “Settings” ( ) button there is the possibility to change the language of the software and check the updatings for the
compositor
In the section “Language” it is possible to change the language of the software
In the section “Connection Options”, it is possible to check if there are some updatings
of the software compositor in ADFweb com website
Checking the option “Check Software Update at Start of Program”, the SW67F38
check automatically if there are updatings when it is launched

Industrial Electronic Devices
ADFweb.com S.r.l.
User Manual
OPC UA Server / LoRaWAN Gateway
Document code: MN67F38_ENG Revision 1 000 Page 15 of 31
In the section “Software Settings”, it is possible to enable/disable some keyboard’s
commands for an easier navigation inside the tables contained in the different
sections of the software

Industrial Electronic Devices
ADFweb.com S.r.l.
User Manual
OPC UA Server / LoRaWAN Gateway
Document code: MN67F38_ENG Revision 1 000 Page 16 of 31
SET COMMUNICATION
By Pressing the “Set Communication” button from the main window for SW67F38 (Fig 2) the
window “Set Communication” appears (Fig 3)
The window is divided in different sections in order to define the different parameters of the
converter:
Select Device
Ethernet Connection
LoRaWAN
OPC UA Server
NTP
Wi-Fi
Figure
3a
:
“Set Communication” windo
w

Industrial Electronic Devices
ADFweb.com S.r.l.
User Manual
OPC UA Server / LoRaWAN Gateway
Document code: MN67F38_ENG Revision 1 000 Page 17 of 31
Figure 3b: “Set Communication
Select Device”
window
Figure 3c: “Set Communication
Ethernet
connection” window
S
ELECT
D
EVICE
This section is used to define the type of Ethernet connection used It is possible to
select:
Only Ethernet Cable
Ethernet cable + Wi-Fi
E
THERNET
C
ONNECTION
The means of the fields for “Ethernet Connection” are:
In the field “Device Name (Hostname)” the Hostname to assign to the
converter is defined;
If the field “Obtain an IP Address Automatically (DHCP for Cable
Connection)” is checked, DHCP for LAN connection is enabled;
If the field “Obtain an IP Address Automatically (DHCP for Wi-Fi
Connection)” is checked, DHCP for Wi-Fi connection is enabled;
If the field “Enable DNS” is checked, DNS protocol is enabled;
In the field “Primary DNS” the IP Address of the primary DNS server is
defined;
In the field “Secondary DNS” the IP Address of the secondary DNS server
is defined

Industrial Electronic Devices
ADFweb.com S.r.l.
User Manual
OPC UA Server / LoRaWAN Gateway
Document code: MN67F38_ENG Revision 1 000 Page 18 of 31
L
O
R
A
WAN
This section is used to define the general parameters of LoRaWAN The means of
the fields are:
In the field “RF Band” the wireless band used for LoRaWAN communication
is defined;
In the field “Network Type” the type of LoRaWAN network is defined;
In the field “Diagnostic Position” it is possible to define an offset into the
internal memory array where the status of the LoRaWAN end devices
configured is saved The diagnostic is made bit to bit, so each bit will
represent a status of a single end device:
o1 End device connected;
o0 End device not connected
The bits’ order will be the same of the end devices’ definition inside the LoRaWAN Access section;
In the field “RX2 Datarate” the data rate on RX2 window is defined
OPC
UA
S
ERVER
The means of the fields for the “OPC UA Server” section are:
In the field “IP Address” the IP address for OPC UA side of the converter is
defined;
In the field “SubNet Mask” the SubNet Mask for OPC UA side of the
converter is defined;
In the field “Gateway” the default gateway of the net is defined This
feature can be enabled or disabled pressing the Check Box field This feature
is used for going out of the net;
In the field “Port” the port of OPC UA Server is defined
Figure
3d
:
“Set Communication
LoRaWAN
” window
Figure 3e: “Set Communication
OPC UA Server”
window

Industrial Electronic Devices
ADFweb.com S.r.l.
User Manual
OPC UA Server / LoRaWAN Gateway
Document code: MN67F38_ENG Revision 1 000 Page 19 of 31
Figure 3g: “Set Communication
Wi-Fi (Access
Point)” window
NTP
The means of the fields for “NTP (Network Time Protocol)” are:
In the field “Server URL” the URL or the IP Address of the NTP Server is
defined;
In the field “Poll Time (seconds)” the polling time for the time
synchronization is defined
W
I
-F
I
This section is used to define the general parameters of Wi-Fi It is possible to
defined the type of Wi-Fi communication:
Access Point;
Station
The means of the fields for Access Point configuration are:
In the field “IP Address” the IP address of the converter is defined;
In the field “Subnet Mask” the SubNet Mask of the converter is defined;
In the field “GATEWAY” the default gateway of the net is defined This
feature can be enabled or disabled pressing the Check Box field This feature
is used for going out of the net;
In the field “SSID” the name of the Wi-Fi network to create is defined;
In the field “Secure Type” the type of security protocol used by the Wi-Fi
network is defined;
In the field “Password” the password used for Wi-Fi connection is defined;
If the field “Enable DHCP” is checked, the converter acts as DHCP Server for the Clients connected If the option is enabled, in the
fields “DHCP First IP Address” and “DHCP SUBNET Mask” the IP Addresses range used for DHCP is defined In the field “Lease
Time (seconds)” the required time for the renewing of the IP Address assigned to the Client is defined;
In the field “Max Client” the maximum number of Wi-Fi Clients accepted is defined;
In the field “Channel” the channel for Wi-Fi communication is defined
Figure 3f: “Set Communication
NTP” window

Industrial Electronic Devices
ADFweb.com S.r.l.
User Manual
OPC UA Server / LoRaWAN Gateway
Document code: MN67F38_ENG Revision 1 000 Page 20 of 31
Figure 3h: “Set Communication
Wi-Fi (Station)”
window
The means of the fields for Station configuration are:
In the field “IP Address” the IP address of the converter is defined;
In the field “Subnet Mask” the SubNet Mask of the converter is defined;
In the field “GATEWAY” the default gateway of the net is defined This
feature can be enabled or disabled pressing the Check Box field This feature
is used for going out of the net;
In the field “SSID” the name of the Wi-Fi network to connect is defined;
In the field “Password” the password used to connect to the Wi-Fi network
is defined