ADF Web HD67B41-B2 User manual

Industrial Electronic Devices
ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com hone +39.0438.30.91.31
User Manual
OPC UA
Server
/
KNX
Document code: MN67B41_ENG Revision 1. Page 1 of 26
User Manual
Revision 1.
English
OPC UA Server / KNX - Converter
(Order Code: HD67B41-B2)
for Website information:
http://www.adfweb.com/?Product=HD67B41
for Price information:
http://www.adfweb.com/?Price=HD67B41-B2
Benefits and Main Features:
Triple electrical isolation
Power Supply 18…35V DC and 8…24 V AC
Temperature range: -4 °C/+85°C (-4 °F/+185°F)
For others OPC UA Server devices, see also the following links:
OPC UA Server from/to …
www.adfweb.com?Product=HD67B26 (Serial)
www.adfweb.com?Product=HD67B27 (Mod us Master)
www.adfweb.com?Product=HD67B28 (Mod us Slave)
www.adfweb.com?Product=HD67B29 (Mod us TCP Master)
www.adfweb.com?Product=HD67B3 (Mod us TCP Slave)
www.adfweb.com?Product=HD67B31 (Bacnet Master)
www.adfweb.com?Product=HD67B32 (Bacnet Slave)
www.adfweb.com?Product=HD67B33 (CAN)
www.adfweb.com?Product=HD67B34 (CANopen)
www.adfweb.com?Product=HD67B35 (DeviceNet Master)
www.adfweb.com?Product=HD67B36 (DeviceNet Slave)
www.adfweb.com?Product=HD67B37 (DMX)
www.adfweb.com?Product=HD67B38 (EtherNet/IP Master)
www.adfweb.com?Product=HD67B39 (EtherNet/IP Slave)
www.adfweb.com?Product=HD67B4 (J1939)
www.adfweb.com?Product=HD67B42 (MQTT)
www.adfweb.com?Product=HD67B43 (NMEA0183)
www.adfweb.com?Product=HD67B44 (NMEA2000)
www.adfweb.com?Product=HD67B45 (PROFINET Master)
www.adfweb.com?Product=HD67B46 (PROFINET Slave)
www.adfweb.com?Product=HD67B47 (SNMP Manager)
www.adfweb.com?Product=HD67B48 (SNMP Agent)
Do you have an your customer protocol?
See the following links:
www.adfweb.com?Product=HD67 3
Do you need to choose a device? do you want help?
Ask it to the following link:
www.adfweb.com?Cmd=helpme
User Manual

Industrial Electronic Devices
ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com hone +39.0438.30.91.31
User Manual
OPC UA
Server
/
KNX
Document code: MN67B41_ENG Revision 1. Page 2 of 26
INDEX:
Page
INDEX 2
UPDATED DOCUMENTATION 2
REVISION LIST 2
WARNING 2
TRADEMARKS 2
SECURITY ALERT 3
EXAMPLE OF CONNECTION 4
CONNECTION SCHEME 5
CHARACTERISTICS 6
CONFIGURATION 6
POWER SUPPLY 7
FUNCTION MODES 8
LEDS 9
KNX 1
ETHERNET 11
USE OF COMPOSITOR SW67B41 12
NEW PROJECT / OPEN PROJECT 13
SOFTWARE OPTIONS 14
SET COMMUNICATION 16
OPC UA ACCESS 18
KNX ACCESS 19
UPDATE DEVICE 21
MECHANICAL DIMENSIONS 23
ORDERING INFORMATIONS 24
ACCESSORIES 24
DISCLAIMER 25
OTHER REGULATIONS AND STANDARDS 25
WARRANTIES AND TECHNICAL SUPPORT 26
RETURN POLICY 26
Pagina 2 di 26
UPDATED DOCUMENTATION:
Dear customer, we thank you for your attention and we remind you that
you need to check that the following document is:
Updated
Related to the product you own
To obtain the most recently updated document, note the “document code”
that appears at the top right-hand corner of each page of this document.
With this “Document Code” go to web page www.adfweb.com/download/
and search for the corresponding code on the page. Click on the proper
“Document Code” and download the updates.
REVISION LIST:
Revision
Date Author
Chapter
Description
1. 13/ 3/2 19 Tf All First release version
WARNING:
ADFweb.com reserves the right to change information in this manual about
our product without warning.
ADFweb.com is not responsible for any error this manual may contain.
TRADEMARKS:
All trademarks mentioned in this document belong to their respective
owners.

Industrial Electronic Devices
ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com hone +39.0438.30.91.31
User Manual
OPC UA
Server
/
KNX
Document code: MN67B41_ENG Revision 1. Page 3 of 26
SECURITY ALERT:
G
ENERAL
I
NFORMATION
To ensure safe operation, the device must be operated according to the instructions in the manual. When using the device, legal and
safety regulation are required for each individual application. The same applies also when using accessories.
I
NTENDED
U
SE
Machines and systems must be designed so the faulty conditions do not lead to a dangerous situation for the operator (i.e.
independent limit switches, mechanical interlocks, etc.).
Q
UALIFIED
P
ERSONNEL
The device can be used only by qualified personnel, strictly in accordance with the specifications.
Qualified personnel are persons who are familiar with the installation, assembly, commissioning and operation of this equipment and
who have appropriate qualifications for their job.
R
ESIDUAL
R
ISKS
The device is state-of-the-art and is safe. The instruments can represent a potential hazard if they are inappropriately installed and
operated by untrained personnel. These instructions refer to residual risks with the following symbol:
This symbol indicates that non-observance of the safety instructions is a danger for people that could lead to serious injury or
death and / or the possibility of damage.
CE
CONFORMITY
The declaration is made by our company. You can send an email to [email protected]om or give us a call if you need it.

Industrial Electronic Devices
ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com hone +39.0438.30.91.31
User Manual
OPC UA
Server
/
KNX
Document code: MN67B41_ENG Revision 1. Page 4 of 26
EXAMPLE OF CONNECTION:

Industrial Electronic Devices
ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com hone +39.0438.30.91.31
User Manual
OPC UA
Server
/
KNX
Document code: MN67B41_ENG Revision 1. Page 5 of 26
Figure
1
: Connection
scheme
for HD67
B
41
-
B2
CONNECTION SCHEME:

Industrial Electronic Devices
ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com hone +39.0438.30.91.31
User Manual
OPC UA
Server
/
KNX
Document code: MN67B41_ENG Revision 1. Page 6 of 26
CHARACTERISTICS:
The HD67B41-B2 is a OPC UA Server / KNX converter.
It allows the following characteristics:
Up to 15 bytes in reading and 15 bytes in writing;
Two-directional information between KNX and OPC UA;
Mountable on 35mm Rail DIN;
Wide power supply input range: 8…24V AC or 12…35V DC;
Wide temperature range: -4 °C / 85°C [-4 °F / +185°F].
CONFIGURATION:
You need Compositor SW67B41 software on your PC in order to perform the following:
Define the parameter of OPC UA;
Define the parameter of KNX line;
Define the list of OPC UA servers connected to the converter;
Define the list of KNX data points accessible on KNX side;
Update the device.

Industrial Electronic Devices
ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com hone +39.0438.30.91.31
User Manual
OPC UA
Server
/
KNX
Document code: MN67B41_ENG Revision 1. Page 7 of 26
POWER SUPPLY:
The devices can be powered between a wide range of tensions. For more details see the two tables below.
VAC
VDC
Vmin Vmax Vmin Vmax
HD67B41-B2 8V 24V 12V 35V
Consumption at 24V DC:
Device W/VA
HD67B41-B2 4
Caution: Not reverse the polarity power
HD67B41 -B2

Industrial Electronic Devices
ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com hone +39.0438.30.91.31
User Manual
OPC UA
Server
/
KNX
Document code: MN67B41_ENG Revision 1. Page 8 of 26
FUNCTION MODES:
The device has got two functions mode depending of the position of the Dip1 of ‘Dip-Switch A’:
The first, with Dip1 in Off position (factory setting), is used for the normal working of the device.
The second, with Dip1 in On position, is used for upload the Project/Firmware.
For the operations to follow for the updating (see ‘UPDATE DEVICE’ section).
According to the functioning mode, the LEDs will have specifics functions (see ‘LEDS’ section).

Industrial Electronic Devices
ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com hone +39.0438.30.91.31
User Manual
OPC UA
Server
/
KNX
Document code: MN67B41_ENG Revision 1. Page 9 of 26
LEDS:
The device has got five LEDs that are used to give information of the functioning status.
The various meanings of the LEDs are described in the table below.
LED Normal Mode Boot Mode
1: Device State (green) Blinks slowly (~1Hz) Blinks quickly: Boot state
Blinks very slowly (~0.5Hz): update in progress
2: OPC UA comm. (yellow) Flashing: OPC UA response
OFF: No OPC UA response
Blinks quickly: Boot state
Blinks very slowly (~0.5Hz): update in progress
3: KNX comm. (yellow) Flashing: KNX communication
OFF: No KNX communication
Blinks quickly: Boot state
Blinks very slowly (~0.5Hz): update in progress
4: Not used OFF Blinks quickly: Boot state
Blinks very slowly (~0.5Hz): update in progress
5: Link Ethernet (green) ON: Ethernet cable connected
OFF: Ethernet cable disconnected
ON: Ethernet cable connected
OFF: Ethernet cable disconnected

Industrial Electronic Devices
ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com hone +39.0438.30.91.31
User Manual
OPC UA
Server
/
KNX
Document code: MN67B41_ENG Revision 1. Page 1 of 26
KNX:
KNX is the standard that allows the automated and decentralized management of the
technologic plans of a big typology of structures: commercial buildings, factories,
houses, public locals, schools and so on.
KNX can be used in all the applications and functions for the building automations:
from lighting to control dampers, to the security, to the heating monitoring, to the
conditioning, to the hydric control and alarms, to energy management and so on.
Characteristics Description TP1-256
Medium Shielded Twisted Pair
Topology Linear, Star, Tree or mixed
Baudrate 96 bps
Device supplying Normal: bus powered devices
Optional: remote powered devices
Device power consumption 3 mA- 12 mA
Power Supply Unit (PSU) DC 3 V
Number of PSU’s per physical
Segment Max. 2
Number of connectable devices
per physical Segment Max. 256
Number of addressable devices
per physical Segment Max. 255
Total cable length per physical
Segment Max. 1 m
Distance between two devices Max. 7 m
(*) Taken from KNX specifications

Industrial Electronic Devices
ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com hone +39.0438.30.91.31
User Manual
OPC UA
Server
/
KNX
Document code: MN67B41_ENG Revision 1. Page 11 of 26
ETHERNET:
The Ethernet connection must be made using Connector3 of HD67B41-B2 with at least a Category 5E cable. The maximum length of the
cable should not exceed 1 m. The cable has to conform to the T568 norms relative to connections in cat.5 up to 1 Mbps. To connect the
device to an Hub/Switch is recommended the use of a straight cable, to connect the device to a PC/PLC/other is recommended the use of a
cross cable.

Industrial Electronic Devices
ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com hone +39.0438.30.91.31
User Manual
OPC UA
Server
/
KNX
Document code: MN67B41_ENG Revision 1. Page 12 of 26
USE OF COMPOSITOR SW67B41:
To configure the Converter, use the available software that runs with Windows called SW67B41. It is downloadable on the site
www.adfweb.com and its operation is described in this document. (This manual is referenced to the last version of the software present on
our web site). The software works with MSWindows (XP, Vista, Seven, 8, 1 ; 32/64bit).
When launching the SW67B41, the window below appears (Fig. 2).
Note:
It is necessary to have installed .Net Framework 4.
Figure 2: Main window for
SW67B
4
1

Industrial Electronic Devices
ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com hone +39.0438.30.91.31
User Manual
OPC UA
Server
/
KNX
Document code: MN67B41_ENG Revision 1. Page 13 of 26
NEW CONFIGURATION / OPEN CONFIGURATION:
The “New Configuration” button creates the folder which contains the entire device’s configuration.
A device’s configuration can also be imported or exported:
To clone the configurations of a programmable “OPC UA Server / KNX - Converter” in
order to configure another device in the same manner, it is necessary to maintain the
folder and all its contents;
To clone a project in order to obtain a different version of the project, it is sufficient to
duplicate the project folder with another name and open the new folder with the
button “Open Configuration”.

Industrial Electronic Devices
ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com hone +39.0438.30.91.31
User Manual
OPC UA
Server
/
KNX
Document code: MN67B41_ENG Revision 1. Page 14 of 26
SOFTWARE OPTIONS:
By pressing the “Settings” ( ) button there is the possibility to change the
language of the software and check the updatings for the compositor.
In the section “Language” it is possible to change the language of the
software.
In the section “Connection Options”, it is possible to check if there are some
updatings of the software compositor in ADFweb.com website.
Checking the option “Check Software Update at Start of Program”, the
SW67B41 check automatically if there are updatings when it is launched.

Industrial Electronic Devices
ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com hone +39.0438.30.91.31
User Manual
OPC UA
Server
/
KNX
Document code: MN67B41_ENG Revision 1. Page 15 of 26
In the section “Software Settings”, it is possible to enable/disable some
keyboard’s commands for an easier navigation inside the tables contained in
the different sections of the software.

Industrial Electronic Devices
ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com hone +39.0438.30.91.31
User Manual
OPC UA
Server
/
KNX
Document code: MN67B41_ENG Revision 1. Page 16 of 26
SET COMMUNICATION:
This section define the fundamental communication parameters of two buses, OPC UA and
KNX.
By Pressing the “Set Communication” button from the main window for SW67B46 (Fig. 2)
the window “Set Communication” appears (Fig. 3).
The means of the fields for “Ethernet Connection” are:
In the field “Device Name (Hostname)” the Hostname to assign to the converter
is defined;
If the field “O tain an IP Address Automatically (DHCP for Ca le
Connection)” is checked, DHCP for LAN connection is enabled;
If the field “Ena le DNS” is checked, DNS protocol is enabled;
In the field “Primary DNS” the IP Address of the primary DNS server is defined;
In the field “Secondary DNS” the IP Address of the secondary DNS server is
defined.
The means of the fields for “OPC UA” are:
In the field “IP Address” the IP address of the converter is defined;
In the field “Su net Mask” the SubNet Mask of the converter is defined;
In the field “GATEWAY” the default gateway of the net is defined. This feature can
be enabled or disabled pressing the Check Box field. This feature is used for going
out of the net;
In the field “Port” the port used for OPC UA communication is defined.
Figure 3: “Set Communication” window

Industrial Electronic Devices
ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com hone +39.0438.30.91.31
User Manual
OPC UA
Server
/
KNX
Document code: MN67B41_ENG Revision 1. Page 17 of 26
The means of the fields for “KNX” are:
In the field “Type” the type of KNX is defined (fixd to ‘KNX TP’);
In the field “ID Device” the ID of the KNX side of the converter is defined.
The means of the fields for “NTP (Network Time Protocol)” are:
In the field “Server URL” the URL or the IP Address of the NTP Server is defined;
In the field “Poll Time (seconds)” the polling time for the time synchronization is defined.

Industrial Electronic Devices
ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com hone +39.0438.30.91.31
User Manual
OPC UA
Server
/
KNX
Document code: MN67B41_ENG Revision 1. Page 18 of 26
Figure 4: “O C UA Server Access” window
OPC
UA
ACCESS:
By Pressing the “OPC UA Access” button from the main window for SW67B41 (Fig. 2) the window “OPC UA Server Access” appears (Fig. 5).
This section is used to define the list of OPC UA variables to read/write.
The means of the checkboxes inside the table are:
If the field “Ena le” is checked, the OPC UA variable is enabled;
In the field “Type” the data format of the OPC UA variable is defined;
In the field “Position” the starting byte of the internal memory arrays where getting the value is defined;
In the field “Length” the byte length of the OPC UA variable is defined;
In the field “Name” the name of the OPC UA variable is defined;
In the field “R/W” the access type of the OPC UA variable is defined;
In the field “Mnemonic” a description of the OPC UA variable is defined.

Industrial Electronic Devices
ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com hone +39.0438.30.91.31
User Manual
OPC UA
Server
/
KNX
Document code: MN67B41_ENG Revision 1. Page 19 of 26
Figure
5
: “KNX Set Access” window
KNX ACCESS:
By pressing the “KNX Access” button
from the main window for SW67B41 (Fig.
2) the “KNX Access” window appears (Fig.
5).
The means of the fields are:
If the field “Ena le” is checked, the
KNX message is enabled;
In the field “Source Address” the Source Address to assign to the KNX message is defined;
In the field “Dest/Group the Group address (2 level structure, 3 level structure or free address structure) or the device address is
defined. In case of Group address, the levels must be separated by ‘/’, in case of Device address, the parts of the address must be
separated by ‘.’;
In the field “APCI” the APCI of the KNX message is defined. You can choose between the following:
oRead: it is used to send a reading request to a KNX device;
oWrite: it is used to send a writing request to a KNX device;
oSpecific value (edited manually).
In the field “Priority” the Priority of the KNX message is defined. You can choose between the following:
oSystem (Highest);
oUrgent;
oNormal;
oLow (Lowest).
In the field “Format” the data format of the KNX message is defined;
In the field “Mul. Factor” a multiplier factor for the data is defined;
If the field “Extended” is checked, the extended format of the KNX message is used;
If the field “ReTest” is checked, the KNX message is re-sent in case of not correct response;
If the field “OnCMD” is checked, the KNX request is sent when a OPC UA request is received;
If the field “On Change” is checked, the gateway sends the KNX command when the data on OPC UA change the value;
If the field “On Timer” is checked, the gateway sends the KNX command cyclically;
In the field “Poll Time” the delay in ms between two KNX commands is defined (if “On Timer” is checked);

Industrial Electronic Devices
ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com hone +39.0438.30.91.31
User Manual
OPC UA
Server
/
KNX
Document code: MN67B41_ENG Revision 1. Page 2 of 26
In the field “Position” insert the address of the internal array where placing the information;
In the field “Bit Mode” insert the start bit of the first byte of the field “Position” where start to insert the data read;
In the field “Lenght” the dimension of the KNX message is defined;
In the field “TimeOut” a timeout is defined: if the KNX message is not received in this time, the data to OPC UA are set to ;
In the field “Mnemonic” the description for the request is defined.
Note:
If the field “On change” is checked and the “Poll Time” is different from , the converter sends the KNX command cyclically and also
when the data is changed.
Note:
If the field “OnCMD”, “OnChange” and “OnTimer” are not checked, the converter only sniffs the bus in order to monitor the status of
the KNX message.
Table of contents
Other ADF Web Server manuals
Popular Server manuals by other brands

Asus
Asus RS160-E4 PA4 user guide

Dell
Dell PowerEdge C6400 Installation and service manual

IBM
IBM HS40 - BladeCenter - 8839 Setup guide

Sun Microsystems
Sun Microsystems Sun Fire E2900 installation guide

Lenovo
Lenovo ThinkServer TS430 warranty and support information

Cisco
Cisco UCS B460 M4 Installation and service note