Adixen ASM 142 User manual

2
3
4
5
5
6
7
7
8
1
Air inlet vent ........................
Calibration .........................
Assistance to the test ................
P/N: 107768 Ed.04
Insert your
Condensed
Manual on the unit
cover
© Axess Technology
ASM 142/142 D/GRAPH/GRAPH D
Detector connections ................
ASM 142/142 D Operator interface .....
ASM GRAPH/GRAPH D Operator interface ..
Start-up ............................
User interface level ..................
Test cycles .........................
Helium signal analog scale display .....
Audio alarm ........................
Zero function .......................
References refer to a specific chapter of
the Operating manual.
For further information, please refer to
Operating manual supplied with your unit.
9
10
11
Condended Manual

2
Main power cord
Main power
switch “I”
Left side Right side
Printer interface /
headphone/
loudspeaker
(option)
RS232 interface
(option)
I/O interface
(option)
Quick connector
exhaust
Long distance
sniffer quick
disconnect
Neutral gas purge (ASM 142
D and ASM GRAPH D only)
Detector connections

AUTO CAL ZERO
NEXT
-
+
RESET
CYCLE
SNIFFER
SET POINTS SPECTRO
MAINTENANCE
OTHER
F1
F3
F2
F4
10
mbar
hPa
Torr
-3
10
-12
10
-11
10
-10
10
-9
10
-8
10
-7
10
-6
10
-5
10
-4
10
-3
10
-2
10
-2
10
-1
110
1
10
2
10
3
COR
mbar l/s
STDBY
INLET PRESSURE
LEAK RATE
EVAC TEST
Pa m
3
/s
Torr l/s
18 17
16 15
20 21 22 23
25 26 27 28
24
19
29
1
11
2
65
7
43
14
13
12
1098
3
1Inlet port pressure analog display
2Control and menu selection indicators (ON when
activated)
3Auto-calibration START/ABORT control key
4Sniffing mode ON/OFF control key
5Auto-zero ON/OFF control key
6Cycle START/STOP control key
7Control keys (4 keys)
8Standby ON/OFF indicator
9Evacuation ON/OFF indicator
10 Test ON/OFF indicator
11 Helium signal analogic display
12 Helium signal analogic scale ON/OFF indicator
13 Helium signal Zero scale ON/OFF indicator
14 Correction factor COR indicator (applied to digital display)
15 Units ON/OFF indicator
16 Helium signal digital display
17 Alphanumeric display (4 lines x 20 characters)
18 Parameter function keys (1 key per display line)
19 Modification access keys (4 keys)
20 NEXT : next display/parameter circular function
21/22 Plus or minus value adjustment, parameter
selection, audio volume adjustment keys
23 RESET of previously displayed values (cancels tem-
porary inputs)
24 Menu selection access key (4 keys)
25 SET POINT menu selection key
26 SPECTRO calibration and analyzer cell configuration
menu selection key
27 MAINTENANCE menu selection key
28 OTHER menus selection key (test mode selection,
inlet VENT selection, date/time)
29 Remote control connection
Setting and maintenance part Operation part
Operator interface ASM 142/142 D

1Inlet port pressure analog display
2Control and menu selection indicators (ON when activated)
3Auto-calibration START/ABORT control key
4Sniffing mode ON/OFF control key
5Auto-zero ON/OFF control key
6Cycle START/STOP control key
7Control keys (4 keys)
8Standby ON/OFF indicator
9Evacuation ON/OFF indicator
10 Test ON/OFF indicator
11 Helium signal analogic display
12 Helium signal analogic scale ON/OFF indicator
13 Helium signal Zero scale ON/OFF indicator
14 Correction factor COR indicator (applied to digital display)
15 Units of measurement selection
16 Helium signal digital display
17 Menu display (4 lines)
18 Spectro pressure analog display
19 Modification access keys (4 keys)
20 RESET: next display/parameter circular function
21/22 Plus or minus value adjustment, parameter
selection, audio volume adjustment keys
23 NEXT of previously displayed values (cancels tempo-
rary inputs)
24 Menu selection access key (4 keys)
25 SET POINT menu selection key
26 SPECTRO calibration and analyzer cell configuration
menu selection key
27 MAINTENANCE menu selection key
28 OTHER menus selection key (test mode selection,
inlet VENT selection, date/time)
29 Remote control connection: connect if before swit-
ching on the detector
30 Graphic interface selection key
31 Color touch screen 4
AUTO CAL ZERO
CYCLE
SNIFFER
SET POINTS SPECTRO
MAINTENANCE
OTHER
10
-12
10
-11
10
-10
10
-9
10
-8
10
-7
10
-6
10
-5
10
-4
10
-3
10
-2
COR
mbar.l/s
STDBY
LEAK RATE
EVAC TEST
Pa.m
3
/s
Torr.l/s
11
17
25 26 27
14
15
20
22 2321
19
24
28
30
31
16
29
18
1
2
1098
13
12
3 4 5 6
7
Setting and maintenance part Operation part
Operator interface ASM GRAPH/GRAPH D

The detector offers 4 user interface
levels for this section to accomodate any
application requirements.
1 Connect the main cable from the detector
to the proper power outlet.
2 Depress the main switch to position “I”. On
the control panel, the indicator lights flash.
3 The following screens are shown on the
LCD.
4 When the detection
pump reaches its
nominal speed, the
unit autocalibrates
itself.
5 When calibration is
completed, the unit is
ready to start a cycle.
STDBYSTDBY
STDBYSTDBY
TESTTEST
TESTTEST
F1
F3 F2
F4
PLEASE WAIT…
adixen ASM...
UNIT : mbar.l/s
SOFT : Lxx Vx.x rxx
F1
F3 F2
F4
PLEASE WAIT…
DETECTION PUMP: 75%
F1
F3 F2
F4
AUTOCAL IN PROGRESS
ELECTR. ZERO ADJUST.
80
F1
F3 F2
F4
READY FOR CYCLE
INLET VENT : off
To know your user interface level and to change it C 120
5
Start-up
ASM 142/GRAPH
After unpacking the unit, please fill up the roughing pump with
oil, as indicated in the Operating manual. E 750
CAUTION User interface level
1
2
3
4
Setting and maintenance part
User part
LEVEL
This level has very limited information on the alphanumeric display (LCD). This level is
generally selected for production types of applications.
No access to control keys (Cycle
key included).
LEVEL
This level allows the operator to visualize some parameters without the possibility of
making any changes.
Same as Level
1
, this level is usually selected for production types of applications.
Access to all the control keys.
LEVEL
Same as level
2
but with possibility to set some parameters. This level is generally
selected for maintenance applications.
LEVEL
This level allows access to all the parameters and is generally used for settings all
the parameters.
Note: When switching from levelL
4
to any other level, the switch can be performed
without using the password. This level is generally selected for R&D applications.

6
HARD VACUUM TEST MODE
Leak detector in stand-by mode; connect the part or
assembly to be tested to the detector.
SNIFFING TEST MODE
Leak detector in stand-by mode; connect the long
distance sniffer probe to the quick connector.
STDBYSTDBY
STDBYSTDBY
TESTTEST
TESTTEST
F1
F3 F2
F4
READY FOR CYCLE
INLET VENT : off
F1
F3 F2
F4
READY FOR CYCLE
INLET VENT : off
CYCLE
STDBYSTDBY
EVACEVAC
EVACEVAC
TESTTEST
SNIFFER
SNIFFER
SNIFFER
SNIFFER
CYCLE
TESTTEST
STDBYSTDBY
Starting a cycle
Ending a cycle
Starting Sniffing test
mode
Ending Sniffing test
mode
(1) As soon as the inlet pressure reaches 10 mbar (7.5
torr), the unit goes in gross leak test mode, or when the
pressure has reached 5 .10-1 mbar (0.37 torr), the unit
goes in fine leak test mode.
F1
F3 F2
F4
READY FOR CYCLE
INLET VENT : off
F1
F3 F2
F4
SNIFFING MODE
PLEASE WAIT…
F1
F3 F2
F4
SNIFFING MODE
Selecting a test mode C 210
(1) Read leak
value
Test cycles
STDBYSTDBY
STDBYSTDBY
TESTTEST
TESTTEST

7
The audio alarm offers 2 modes of operation. They are both linked to the zero function.
zero function not activated: the audio alarm starts when the He signal exceeds a fixed
set point: this set point is programmable.
zero function activated: the audio alarm is modulated with respect to the position of
the helium background.
To active/deactive audio alarm C 520
Blinking led = reject point
AUTO CAL ZERO
NEXT
-
+
RESET
CYCLE
SNIFFER
SET POINTS SPECTRO
MAINTENANCE
OTHER
F1
F3
F2
F4
10
mbar
hPa
Torr
-3
10
-12
10
-11
10
-10
10
-9
10
-8
10
-6
10
-5
10
-4
10
-3
10
-2
10
-2
10
-1
110
1
10
2
10
3
COR
mbar.l/s
STDBY
INLET PRESSURE
LEAK RATE
EVAC TEST
Pa.m3/s
Torr.l/s
10
-7
How to read the He signal analog scale?
reject point is visualized by a blinking led.
if the leak value exceeds the reject point, the leds
will turned red (the blinking led will turn orange).
if the leak value remains under the reject point, the leds will remain green.
Example : Reject point = 1 .10-7 mbar l/s
He signal analog scale display Audio alarm
Leak detector in hard vacuum or
sniffing test mode and zero function
not activated.

8
ZERO
ZERO
AUTO CAL ZERO
NEXT
-
+
RESET
CYCLE
SNIFFER
SET POINTS SPECTRO
MAINTENANCE
OTHER
F1
F3
F2
F4
10
mbar
hPa
Torr
-3
10
-12
10
-11
10
-10
10
-9
10
-8
10
-6
10
-5
10
-4
10
-3
10
-2
10
-2
10
-1
110
1
10
2
10
3
COR
mbar.l/s
STDBY
INLET PRESSURE
LEAK RATE
EVAC TEST
Pa.m
3
/s
Torr.l/s
10
-7
Zero function Deactivation of zero function:
The digital display shows the standard He signal.
Use Helium signal analog scale.
Analog display:
When zero function is activated, use the Helium signal zero scale.
The He signal zero scale displays 2 leds signal centered around the zero value.
Example:
2 leds ash
1 .10-7 1 .10-8 1.1 .10-7 9 .10-8 2 .10-7
Purpose: the zero function offers the operator the possibility to detect small leaks that are
smaller than the helium background.
Activation of zero function: connect the part or installation to be tested.
Operator could find an example in the Operating manual C 540
CYCLE
on the digital display, the detector He background displays.
ZERO
ZERO
the digital display becomes 0.0E-00. On and after this time, it will display only
Helium variation.

9
Purpose: the air inlet valve vents the inlet of the detector back to atmosphere at the end
of the test.
The indicator “inlet valve = off” indicates that the venting valve is not activated
(= closed) at the end of cycle.
The setting by default is «off» (= valve closed).
F1
F3 F2
F4
READY FOR CYCLE
INLET VENT : off
F3F3
(opening)
/(closing)
F3F3
Opening / closing air inlet valve
(user level 2, 3or 4)
To open/close air inlet valve with user level 1C 500
Air inlet vent

10
Internal: The internal autocalibration is automatically activated
during the start-up process. It doesn’t require any
operator action. Thanks to the initial autocalibration,
the leak detector can be immediately operational.
Internal autocalibration on request: it can be started by the
operator whenever needed (the unit has to be off-cycle).
The result of the autocalibration process is displayed.
External: The external autocalibration allows direct readout in cases of operation with
an auxiliary pumping system.
F1
F3 F2
F4
READY FOR CYCLE
INLET VENT : off
F1
F3 F2
F4
READY FOR CYCLE
INLET VENT : off
F1
F3 F2
F4
AUTOCAL IN PROGRESS
ELECTR. ZERO ADJUST.
80
To perform an external calibration C 303
AUTOCAL
Calibration

11
The leak detector offers to the user 4 interesting
functions in order to improve test.
MEMO FUNCTION
CYCLE END
HELIUM POLLUTION
PREVENTION
BARGRAPH ZOOM ON
THE REJECT POINT
Memo function
Cycle end
Bargraph zoom on the reject point
Helium pollution prevention
To active/deactive this function and adjust display time of the
leak value
C 550
To active/deactive this function and adjust roughing and measure
times C 530
To active/deactive this function C 510
To active/deactive this function C 560
Assistance to the test
Memorization of the latest He signal measured after
depressing the CYCLE key at the end of the cycle.
Device that prevents the unit from getting polluted with
Helium.
Display a greater resolution of the He signal around the
reject point.
Automatic control of the roughing and measure timers.
Other manuals for ASM 142
1
This manual suits for next models
3
Table of contents
Other Adixen Security Sensor manuals
Popular Security Sensor manuals by other brands

Endress+Hauser
Endress+Hauser Nivotester FTL325N-**** Series operating instructions

Leuze electronic
Leuze electronic ERS200-M0C3-M20-HLR operating instructions

Siemens
Siemens DELTA reflex 5TC7 2 Series Operating and mounting instructions

SICK
SICK Prime KTX-WN91242242ZZZZ manual

Smartwares
Smartwares SH5-TSO-A quick start guide

Amcrest
Amcrest SmartHome AL-KIT1-PP quick start guide