manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. ADTRAN
  6. •
  7. Chassis
  8. •
  9. ADTRAN MX2820 M13 MUX User manual

ADTRAN MX2820 M13 MUX User manual

This manual suits for next models

1

Other ADTRAN Chassis manuals

ADTRAN MX2820 User manual

ADTRAN

ADTRAN MX2820 User manual

ADTRAN Total Access 1500 Chassis 1180001L1 Instruction Manual

ADTRAN

ADTRAN Total Access 1500 Chassis 1180001L1 Instruction Manual

ADTRAN MX2820 User manual

ADTRAN

ADTRAN MX2820 User manual

ADTRAN OPTI-6100 LMX User manual

ADTRAN

ADTRAN OPTI-6100 LMX User manual

ADTRAN Total Access 850 Instruction Manual

ADTRAN

ADTRAN Total Access 850 Instruction Manual

ADTRAN 1181001L1 Instruction Manual

ADTRAN

ADTRAN 1181001L1 Instruction Manual

ADTRAN OPTI-3 WMC User manual

ADTRAN

ADTRAN OPTI-3 WMC User manual

Popular Chassis manuals by other brands

Phoenix Mecano HARTMANN ELECTRONIC PXCe4006 Series user manual

Phoenix Mecano

Phoenix Mecano HARTMANN ELECTRONIC PXCe4006 Series user manual

Advantech IPC-623 Series user manual

Advantech

Advantech IPC-623 Series user manual

IMC Networks iMcV/18 installation guide

IMC Networks

IMC Networks iMcV/18 installation guide

Lenovo ThinkSystem SR665 V3 user guide

Lenovo

Lenovo ThinkSystem SR665 V3 user guide

Wuntronic PCI4DRQ user guide

Wuntronic

Wuntronic PCI4DRQ user guide

EtherWAN EMC400 quick start guide

EtherWAN

EtherWAN EMC400 quick start guide

Overland Storage SnapSAN S1000 Replacement instructions

Overland Storage

Overland Storage SnapSAN S1000 Replacement instructions

Philips LC4.1E A Service manual

Philips

Philips LC4.1E A Service manual

Supermicro SCF418 Series user manual

Supermicro

Supermicro SCF418 Series user manual

Supermicro SC823MTQ-R700LPB user manual

Supermicro

Supermicro SC823MTQ-R700LPB user manual

HP A7503-S Product End-of-Life Disassembly Instructions

HP

HP A7503-S Product End-of-Life Disassembly Instructions

SilverStone RMS08 Series manual

SilverStone

SilverStone RMS08 Series manual

Allied Telesis AT-MMCR18 installation guide

Allied Telesis

Allied Telesis AT-MMCR18 installation guide

Cisco Nexus 7010 Installing

Cisco

Cisco Nexus 7010 Installing

Chenbro RM437 Series user manual

Chenbro

Chenbro RM437 Series user manual

American Control Electronics MGB400 quick start guide

American Control Electronics

American Control Electronics MGB400 quick start guide

Advantech HPC-7480 user manual

Advantech

Advantech HPC-7480 user manual

Cisco USC 5030 installation guide

Cisco

Cisco USC 5030 installation guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

C A U T I O N !
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY.
HANDLING PRECAUTIONS REQUIRED.
MX2820
M13 MUX
P/N 1186002L2
CLEI: M3C3R30A_ _
MX2820 ±24 VDC M13 MUX
1186002
M13 MUX
ALM
ACT
TEST
STAT
TEST
STAT DS1
DS3
#61186002L2-22B#
DESCRIPTION
The MX2820 M13 MUX is a plug-in unit for the MX2820 chassis that provides an M13
multiplexer function to the MX2820 system. Two MX2820 M13 MUX cards are used together
to provide a redundant M13 multiplexer circuit. The MX2820 M13 MUX:
♦provides 1:1 redundancy
♦meets the requirements for NEBS Level 3.
INSTALLATION AND TURNUP
After unpacking the unit, inspect it for damage. If damage is found, file a claim with the carrier
and then contact ADTRAN Customer Service. Refer to the Warranty Statement on this Job Aid.
This module occupies a MUX slot in the MX2820 chassis. To install the M13 MUX in the
chassis, perform the following steps:
1. Pull the ejector tab into the down position and gently but firmly push the MUX into the
selected MUX slot. Simultaneous thumb pressure at the top and at the bottom of the unit
will ensure a good seat of the MUX into the backplane connector.
2. Push the ejector tab up and closed against the front panel.
Upon installation, the MUX will begin a self-test. This is followed with the LEDs reflecting
the true state of the hardware.
OPERATIONAL SPECIFICATIONS
♦Operates from A or B input voltage power feeds.
–48 VDC Systems: –42 VDC to –56 VDC
–24 VDC Systems: –22 VDC to –27 VDC
+24 VDC Systems: +22 VDC to +27 VDC
♦Operates over extended temperature range of –40ºC to +50ºC without fans
or –40ºC to +65ºC with fans.
♦Storage –40ºC to +85ºC. Relative humidity to 95 percent, noncondensing.
COMPLIANCE
♦The MX2820 M13 MUX complies with UL 60950, NEBS Level 3, and
GR-1089-CORE.
♦The MX2820 M13 MUX is intended for installation in restricted access areas only.
♦The MX2820 M13 MUX is intended for installation in a Type “B” or “E” enclosure.
This device complies with Part 15 of the FCC rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must accept
any interference received, including interference that may cause undesired operation.
Changes or modifications not expressly approved by ADTRAN could void the user’s authority
to operate this equipment.
PROVISIONING
All provisioning of the MX2820 M13 MUX will be handled through the SCU. The menu tree
on the reverse of this Job Aid provides the options and default settings for the MX2820 M13
MUX.
Code Input Output
Power Code C C
Telecommunication Code (TC) – –
Installation Code (IC) A –
LED STATUS FOR ACTIVE MUX
LED STATUS FOR STANDBY MUX
ACT !Green Normal (All OK)
!/!Green/Amber (Alternating) Normal and console open
!Red Self-test failed
!Amber Software update in progress
!/!Red/Amber (Alternating) Self-test failed and console open
4Red (Flashing) Module has failed
ALM !Green No critical, major, or minor alarms
!Red Major or minor alarm in progress
4Red (Flashing) Critical alarm in progress
DS3 STAT !Green Normal (DS3 OK)
!Red AIS, OOF, RAI, Idle alarms
4Red (Flashing) DS3 LOS or DS3 Failure (critical)
4Red (Flashing once per event) Single/Burst DS3 code violations
!/!Red/Green (Alternating) DS3 XCV threshold exceeded
DS3 TEST "Off No DS3 tests in progress
!Amber In test (locally originated)
4Amber (Flashing) In test (remotely originated)
DS1 STAT "Off All DS1s are disabled
!Green Enabled DS1s normal (All OK)
!Red Non-critical DS1 alarm (CAIS, LAIS)
4Red (Flashing) LOS on an enabled line (critical DS1
alarm; non-critical system alarm)
4Red (Flashing once per event) Single/Burst RX DS1 code violation
!/!Red/Green (Alternating) DS1 XCV threshold exceeded
DS1 TEST "Off No DS1 tests in progress
!Amber In test (locally originated)
4Amber (Flashing) In test (remotely originated)
ACT 4Green (Flashing) Normal (All OK)
!Amber Software update in progress
4Red Failure
ALM "Off Permanent state during standby
DS3 STAT "Off Normal (DS3 OK)
4Red (Flashing) In test (remotely originated)
DS3 TEST "Off Permanent state during standby
DS1 STAT "Off Normal (DS1s OK)
4Red (Flashing) DS1 Failure
DS1 TEST "Off Permanent state during standby
61186002L2-22B
0408
PRICING AND AVAILABILITY 800.827.0807
TECH SUPPORT 800.726.8663
RETURN FOR REPAIR 256.963.8722
www.adtran.com
61186002L2-22B
Warranty:ADTRAN will replace or repair this product within the warranty period if it does not meet its published specifications or fails while in service.
Warranty information can be found at www.adtran.com/warranty.
1. Configuration
2. Provisioning
3. Status
4. Test
5. Performance Monitoring
4. Protection
Note: An asterisk (*) indicates default setting
5. Save Provisioning
1. 0-133 ft*
T1:
E1:
3. 266-399 ft
2. 133-266 ft
5. 533-655 ft
1. 0-6dB Loss
4. 399-533 ft
1. 2 seconds*
29. Set Multiple
30. Auto Enable Delay
3. 2 hours
2. 1 hour
5. 1 day
4. 12 hours
6. 2 days
7. 7 days
1. Disabled
3. 5 Minutes*
2. 1 Minute
5. 15 Minutes
4. 10 Minutes
6. 30 Minutes
7. 45 Minutes
8. 60 Minutes
1. Near End Daily
3. Far End Daily
2. Near End Quarter Hourly
5. Near End Daily Thresholds
4. Far End Quarter Hourly
6. Near End Quarter Hourly Thresholds
7. Near End Daily Thresholds
8. Near End Quarter Hourly Thresholds
9. Clear DS3 Statistics
1. Data Mode*
3. Digital Loopback
2. Line Loopback
5. Remote ALL T1/E1
4. Remote Loopback
1. QRSS*
3. ALL ZEROES
2. ALL ONES
5. 1 in 8 (1:7)
4. 2 in 8 (2:6)
6. 2 ^15-1 INV
1. Data Mode*
2. Network Loopback
1. Data Mode*
T1:
3. Analog Network
2. Tributary
5. CODEC Line/Net
4. Digital Line/Net
6. Remote Loopback
7. LS CSU Loopback
8. LS CSU LB w/BERT
9. LS NIU Loopback
10. LS NIU LB w/BERT
11. LS Line BERT
1. Data Mode*
E1:
T1/E1 Loopbacks (T1/E1 #1-28)
29. DS3 Loopbacks
3. Analog Network
2. Tributary
5. CODEC Line/Net
4. Digital Line/Net
6. Remote Loopback
7. Line BERT
CLEI Code
Serial Number
Part Number
Code Checksum
Code Version
Boot Version
Boot Checksum
Self Test
1. Disabled*
3. 1E-4
2. 1E-3
5. 1E-6
4. 1E-5
1. Disabled*
3. 1E-4
2. 1E-3
5. 1E-6
4. 1E-5
1. Near End Daily
3. Near End Daily Thresholds
2. Near End Quarter Hourly
4. Near End Quarter Hourly Thresholds
5. Clear T1/E1 Statistics
1. Disabled
3. FEAC
2. FEAC/C-BIT*
4. C-BIT
1. DS3 Framing
3. DS3 Remote Loopbacks
2. DS3 Timing
7-13. DS2 Mode (DS2 #1-7)
4. DS3 XCV Threshold
1. T1/E1 State
3. T1/E1 Line Length
2. T1/E1 Line Coding
5. T1/E1 Circuit Protection
4. T1/E1 Loopback Detection
6. T1/E1 Line Identification
7. T1/E1 XCV Threshold
(T1/E1 #1-28)
(T1/E1 #1-28)
(T1/E1 #1-28)
(T1/E1 #1-28)
(T1/E1 #1-28)
(T1/E1 #1-28)
7. Card Reset
1. Network Interface
2. T1/E1 Interfaces
3. Service States
6. Restore Factory Defaults
8. Auto Save
9 . Loopback Timeout
10 . Card Pair ID
1. AMI
2. B8ZS/HBD3*
1. Disabled
2. Enabled
3. Auto Enable*
T1/E1 #1-28
29. DS3
30. Set Multiple
1. Card nA
2. Card nB
3. Facility Service States
2. Enabled*
1. Disabled
30. Protection Threshold (1-28): 1*
2. Enabled*
1. Disabled
1. Disabled*
2. CSU (T1 Only)
3. NIU (T1 Only)
1. Perform Manual Switch
2. Minimum Switching Period (sec.) (10*)
3. Maximum Switch Threshold (3*)
1. DS3 Statistics
2. T1/E1 Statistics
3. Clear ALL Statistics
1. M12 (4xT1)*
2. G.747 (3xE1)
1. C-BIT
2. M13*
1. IS*
2. OOS
1. Loop
2. Local*
30-36. DS2 #1-7 Loopbacks
37. Reset ALL Tests
38. Pattern
14. DS3 Equipment Identification
(T1/E1 #1-28)
Shelf: 1 Slot: 1A ADTRAN MX2820 System 04/15/04 16:33
Unacknowledged Alarms: CRITICAL MAJOR TID: SysName not set
Status
DS3 State DS2 State
State = ALARM <1-7> = NA NA NA NA NA NA NA
Alarm = LOS
Rx Framing = M13 T1/E1 State
Remote = Unknown <1-4> = AUTO AUTO AUTO AUTO
<5-8> = AUTO AUTO AUTO AUTO
Multiplexer State <9-12> = AUTO AUTO AUTO AUTO
Alarm = None <13-16> = AUTO AUTO AUTO AUTO
Protection = Circuit <17-20> = AUTO AUTO AUTO AUTO
Card Comm. = OK <21-24> = AUTO AUTO AUTO AUTO
<25-28> = AUTO AUTO AUTO AUTO
Slot 1A
Status = Active
Slot 1B
Status = Standby
’?’ - System Help Screen
12. HS CSU Loopback
13. HS CSU LB w/BERT
14. HS NIU Loopback
15. HS NIU LB w/BERT
16. HS Line BERT
5. IP Forwarding Protocol
6. IP Forwarding MTU
1. ADTRAN*
2. PPP
1. 260 (PREFERRED)*
2. 1500
4. Clear Number of Switches
MX2820 ±24 VDC M13 MUX