manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. ADTRAN
  6. •
  7. Network Hardware
  8. •
  9. ADTRAN 1442702PG1 User manual

ADTRAN 1442702PG1 User manual

jobAid
DESCRIPTION
TheOC‐3SmallForm‐FactorPluggableBi‐Directional1310/1550
nm(SFPOC‐3)plugsintoADTRANOC‐3equipmentdesigned
toacceptSmallForm‐factorPluggables(SFPs).
Installedintoanappropriatehostunit,theSFPOC‐3providesan
OC‐3interfacetothesupportingsystem.
NOTE
Toensurecompatibility,refertothedocumentationprovided
withthehostmodule.
ThefollowingfeaturesaresupportedontheSFPOC‐3:
♦SONETOC‐3compatible(155.52Mb/s)single‐fiberoperation
♦20kmmaximumopticalspan
CAUTION
!
Duetocompliancecertificationrequirements,useonlySFPs
suppliedbyADTRANwiththehostmodule.ADTRANcannot
certifysystemintegritywithotherSFPs.
SPECIFICATIONS
♦OpticalSpecifications:
◊Opticaltransmitlevel:–14dBmto–8dBm
◊Opticalreceivelevel:–32dBmto–8dBm
◊TransmitWavelength:1310nm
◊ReceiveWavelength:1550nm
◊Opticalbudget:17(±1)dBm
◊Opticalconnectors:LC
♦ExtendedEnvironmentalSupport:
◊Operationaltemperaturerange:–40°Cto+65°C
◊Storagetemperaturerange:–40°Cto+85°C
◊Relativehumidityto95%,noncondensing
OC-3 Small Form-Factor Pluggable
Bi-Directional 1310/1550 nm
INSTALLATION
ToinstalltheSFPOC‐3intoanappropriatemodule,completethe
followingsteps:
1. InspecttheSFPOC‐3.Ifdamaged,fileaclaimwiththecar‐
rierandthencontactADTRANCustomerSupport.
CAUTION
!
DonotremovetheprotectiveendcapfromtheSFPuntilthefiber
opticcableisreadytobeconnected.
2. InserttheSFPOC‐3intotheSFPcageonthemodule.Ensure
thatthemanufacturer’slabelontheSFPisfacingupwardfor
correctinstallation.
3. SlidetheSFPOC‐3allthewayintothereceptacleuntilthere
isanaudible“click”.
NOTE
ThelatchontheSFPisusedtoremovetheSFPfromthecageon
thecircuitcard.
PROVISIONING
TheSFPOC‐3isnotdirectlyprovisionable.ToprovisiontheSFP
OC‐3,accessthemenusystemofthehostmodule.Refertothe
“Provisioning”sectionoftheJobAidorI&Mprovidedwiththe
hostmoduleforprovisioningdetails.
SAFETY AND REGULATORY COMPLIANCE
CAUTION
!
ElectrostaticDischarge(ESD)candamageelectronicmodules.
Whenhandlingmodules,wearanantistaticdischargewriststrap
topreventdamagetoelectroniccomponents.Placemodulesin
antistaticpackingmaterialwhentransportingorstoring.When
workingonmodules,alwaysplacethemonanapproved
antistaticmatthatiselectricallygrounded.
TheSFPOC‐3isNRTLListedtotheapplicableULstandards.The
SFPOC‐3meetsorexceedsalltheapplicablerequirementsof
NEBS,TelcordiaGR‐63‐CORE,GR‐1089‐CORE,andETSIEN
300368.
TheSFPOC‐3isintendedfordeploymentinCentralOfficetype
facilities,EEEs,EECs,andlocationswheretheNECapplies(for
example,CustomerPremises).TheSFPOC‐3istobeinstalledin
ADTRANproductsinRestrictedAccessLocationsonly,and
installedbytrainedservicepersonnel.
CLEI: SITRAALA_ _
Product P/N: 1442702PG1
Issue Date: December 2010
Document P/N: 61442702PG1-22D
C A U T I O N
C A U T I O N
!
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY.
HANDLING PRECAUTIONS REQUIRED.
Warranty: ADTRAN will replace or repair this product within the warranty period if it does not
meet its published specifications or fails while in service. Warranty information can
be found online at www.adtran.com/warranty.
©2010 ADTRAN, Inc. All Rights Reserved.
ADTRAN CUSTOMER CARE:
From within the U.S. 1.800.726.8663
From outside the U.S. +1 256.963.8716
PRICING AND AVAILABILITY 1.800.827.0807
*61442702PG1-22D*
ThisdevicecomplieswithPart15oftheFCCrules.Operationis
subjecttothefollowingtwoconditions:
1. Thisdevicemaynotcauseharmfulinterference.
2. Thisdevicemustacceptanyinterferencereceived,including
interferencethatmaycauseundesiredoperation.
ChangesormodificationsnotexpresslyapprovedbyADTRAN
couldvoidtheuserʹsauthoritytooperatethisequipment.
CAUTION
C
TheSFPOC‐3containsaClass1laserthatcomplieswiththe
LaserSafetyrequirementsofFDA21CFR1040.10and1040.11,
andEN60825‐1,and‐2.TheSFPOC‐3isNRTLListedandCB
CertifiedtoallapplicableAmericanandEuropeansafety
standards.
CAUTION
!
♦ PerGR‐1089‐CORESection9,theSFPOC‐3doesnothavean
internalDCconnectionbetweenbatteryreturnandframe
ground.
♦ TheADTRANsystemthattheSFPOC‐3isbeingdeployedinis
designedandintendedforinstallationaspartofaCommon
BondingNetwork(CBN),orIsolatedBondingnetwork(IBN).
♦ TheSFPOC‐3canbeinstalledinaDC‐I(isolated)orDC‐C
(common)configuration.Forinstallationswhereothercards
orthehostsystemhaveinternalconnectionsbetweenbattery
returnandframeground,thesystemwouldbeintendedfor
deploymentonlyinaDC‐Cconfiguration.
♦ TheADTRANsystemchassisframegroundterminalmustbe
connectedtoareliableearthgroundtoensurethatthemetal
enclosureoftheSFPOC‐3isproperlygroundedviathe
backplaneconnector.
NOTE
♦ TheOC‐3port(s)areopticalandthereforearenotclassifiedas
anytypeofportasdefinedinAppendixBofGR‐1089‐CORE
Issue5.
♦ ThisSFPOC‐3iscompliantwithSFF‐8472“DigitalDiagnostics
MonitoringInterfaceforOpticalTransceivers,”Revision9.3.
♦ ThisSFPOC‐3iscompliantwiththeSmallForm‐Factor
Pluggable(SFP)Multi‐SourceAgreement(MSA).
♦ ThisproductisdesignedtobedeployedinGR‐3108‐CORE
environmentclass1or2asdefinedinGR‐3108‐COREissue2.
TheSFPOC‐3isdesignedtomeetthefollowingenvironmental
classes:
♦ETSIEN300019‐1‐1“Classificationofenvironmental
conditions;Storage,”Class1.2
♦ETSIEN300019‐1‐2“Classificationofenvironmental
conditions;Transportation,”Class2.3
♦ETSIEN300019‐1‐3“Classificationofenvironmental
conditions;Stationaryuseatweather‐protectedlocations,”
Class3.3
♦ETSIEN300386“ElectromagneticcompatibilityandRadio
spectrumMatters(ERM);Telecommunicationnetwork
equipment;ElectromagneticCompatibility(EMC)
requirements”
Theequipmentisdesignedtofunctionwithoutdegradation
duringexposuretoalltestseveritiesperClass3.3.
ThisproductmeetsEURoHSDirective2002/95/ECand/orappli‐
cableexemptions.Refertowww.adtran.comforfurtherinfor‐
mationonRoHS/WEEE.

This manual suits for next models

1

Other ADTRAN Network Hardware manuals

ADTRAN TRACER 64 0 Series User manual

ADTRAN

ADTRAN TRACER 64 0 Series User manual

ADTRAN Network Interface Module T1/FT1 User manual

ADTRAN

ADTRAN Network Interface Module T1/FT1 User manual

ADTRAN Total Access 372 Product manual

ADTRAN

ADTRAN Total Access 372 Product manual

ADTRAN DSU 56/64 User manual

ADTRAN

ADTRAN DSU 56/64 User manual

ADTRAN Total Access 1500 Total Reach DDS-DP Product manual

ADTRAN

ADTRAN Total Access 1500 Total Reach DDS-DP Product manual

ADTRAN 1203060L1 User manual

ADTRAN

ADTRAN 1203060L1 User manual

ADTRAN NetVanta 834 Owner's manual

ADTRAN

ADTRAN NetVanta 834 Owner's manual

ADTRAN T1 CSU ACE User manual

ADTRAN

ADTRAN T1 CSU ACE User manual

ADTRAN 1442300G1 User manual

ADTRAN

ADTRAN 1442300G1 User manual

ADTRAN T200 HTU-R User manual

ADTRAN

ADTRAN T200 HTU-R User manual

ADTRAN Smart 16e Shelf User manual

ADTRAN

ADTRAN Smart 16e Shelf User manual

ADTRAN Total Access DSLAM 16-Port ADSL2+ Access Module... User manual

ADTRAN

ADTRAN Total Access DSLAM 16-Port ADSL2+ Access Module... User manual

ADTRAN GPON TA352 User manual

ADTRAN

ADTRAN GPON TA352 User manual

ADTRAN Express 6530 6530 Manual

ADTRAN

ADTRAN Express 6530 6530 Manual

ADTRAN T200 IDSL Instruction Manual

ADTRAN

ADTRAN T200 IDSL Instruction Manual

ADTRAN Total Access 480 User manual

ADTRAN

ADTRAN Total Access 480 User manual

ADTRAN NetVanta Series User manual

ADTRAN

ADTRAN NetVanta Series User manual

ADTRAN TR OCU DP Instruction Manual

ADTRAN

ADTRAN TR OCU DP Instruction Manual

ADTRAN E1 Instruction Manual

ADTRAN

ADTRAN E1 Instruction Manual

ADTRAN T200 H2TU-R Instruction Manual

ADTRAN

ADTRAN T200 H2TU-R Instruction Manual

ADTRAN T1 Nx64 HTU-R Instruction Manual

ADTRAN

ADTRAN T1 Nx64 HTU-R Instruction Manual

ADTRAN NIU3 Instruction Manual

ADTRAN

ADTRAN NIU3 Instruction Manual

ADTRAN DSU IQ User manual

ADTRAN

ADTRAN DSU IQ User manual

ADTRAN NetVanta 1335 Series User manual

ADTRAN

ADTRAN NetVanta 1335 Series User manual

Popular Network Hardware manuals by other brands

ASTRON DD-600 Installation and usage manual

ASTRON

ASTRON DD-600 Installation and usage manual

Lenovo EMC2 px Series quick start guide

Lenovo

Lenovo EMC2 px Series quick start guide

Huawei CR-C2CF Specifications

Huawei

Huawei CR-C2CF Specifications

Black Box V5.1 user manual

Black Box

Black Box V5.1 user manual

Atlasen LEO v2 installation guide

Atlasen

Atlasen LEO v2 installation guide

INSIGHT DLP SENSOR 310 Hardware installation guide

INSIGHT

INSIGHT DLP SENSOR 310 Hardware installation guide

Epiq Solutions Sidekiq Z2 Development manual

Epiq Solutions

Epiq Solutions Sidekiq Z2 Development manual

Cabletron Systems Netlink FRX4000 Installation and setup guide

Cabletron Systems

Cabletron Systems Netlink FRX4000 Installation and setup guide

Wunda Smart Connection Box v2.0 Quick install guide

Wunda

Wunda Smart Connection Box v2.0 Quick install guide

Fortinet FortiAnalyzer 800G quick start guide

Fortinet

Fortinet FortiAnalyzer 800G quick start guide

Idis DR-8364F quick guide

Idis

Idis DR-8364F quick guide

FS T5850-24S2C quick start guide

FS

FS T5850-24S2C quick start guide

Tektronix 7B92A instruction manual

Tektronix

Tektronix 7B92A instruction manual

Lucent Technologies Stinger Administration guide

Lucent Technologies

Lucent Technologies Stinger Administration guide

Allied Telesis AT-SPEX datasheet

Allied Telesis

Allied Telesis AT-SPEX datasheet

Ruckus Wireless ZoneFlex P300 Quick setup guide

Ruckus Wireless

Ruckus Wireless ZoneFlex P300 Quick setup guide

Lanner ECA-4025 user manual

Lanner

Lanner ECA-4025 user manual

HP Mv2120 - Media Vault Network Drive datasheet

HP

HP Mv2120 - Media Vault Network Drive datasheet

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.