manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. ADTRAN
  6. •
  7. Network Hardware
  8. •
  9. ADTRAN 1442120G1 User manual

ADTRAN 1442120G1 User manual

Other ADTRAN Network Hardware manuals

ADTRAN Total Access 1248 User manual

ADTRAN

ADTRAN Total Access 1248 User manual

ADTRAN ENHANCED PSD 239 H2R User manual

ADTRAN

ADTRAN ENHANCED PSD 239 H2R User manual

ADTRAN TSU LT User manual

ADTRAN

ADTRAN TSU LT User manual

ADTRAN HDSL4 User manual

ADTRAN

ADTRAN HDSL4 User manual

ADTRAN NetVanta 6355 PoE User manual

ADTRAN

ADTRAN NetVanta 6355 PoE User manual

ADTRAN NetVanta 1224 Instruction Manual

ADTRAN

ADTRAN NetVanta 1224 Instruction Manual

ADTRAN CenturyLink C424G User manual

ADTRAN

ADTRAN CenturyLink C424G User manual

ADTRAN U-BR1TE Maintenance and service guide

ADTRAN

ADTRAN U-BR1TE Maintenance and service guide

ADTRAN TRACER 4106 Plan User guide

ADTRAN

ADTRAN TRACER 4106 Plan User guide

ADTRAN NetVanta 5660 User manual

ADTRAN

ADTRAN NetVanta 5660 User manual

ADTRAN DSU III ARdc User manual

ADTRAN

ADTRAN DSU III ARdc User manual

ADTRAN Total Access 3000 Manual

ADTRAN

ADTRAN Total Access 3000 Manual

ADTRAN T200 SHDSL User manual

ADTRAN

ADTRAN T200 SHDSL User manual

ADTRAN NIU3 Instruction Manual

ADTRAN

ADTRAN NIU3 Instruction Manual

ADTRAN TRACER 5045 User manual

ADTRAN

ADTRAN TRACER 5045 User manual

ADTRAN ESU 120e User manual

ADTRAN

ADTRAN ESU 120e User manual

ADTRAN XFP User manual

ADTRAN

ADTRAN XFP User manual

ADTRAN NetVanta 838 User manual

ADTRAN

ADTRAN NetVanta 838 User manual

ADTRAN ATLAS 810 Plus User manual

ADTRAN

ADTRAN ATLAS 810 Plus User manual

ADTRAN jobAid 1442351G1 User manual

ADTRAN

ADTRAN jobAid 1442351G1 User manual

ADTRAN Total Access 3050 User manual

ADTRAN

ADTRAN Total Access 3050 User manual

ADTRAN U-BR1TE User manual

ADTRAN

ADTRAN U-BR1TE User manual

ADTRAN NetVanta 838 Operation manual

ADTRAN

ADTRAN NetVanta 838 Operation manual

ADTRAN DS3 NIU3 User manual

ADTRAN

ADTRAN DS3 NIU3 User manual

Popular Network Hardware manuals by other brands

socomec SNMP Card II quick start guide

socomec

socomec SNMP Card II quick start guide

NVR SYSTEMS 4-CH user manual

NVR SYSTEMS

NVR SYSTEMS 4-CH user manual

Draytek VigorSwitch G1240 quick start guide

Draytek

Draytek VigorSwitch G1240 quick start guide

Westermo TD-34 LV installation manual

Westermo

Westermo TD-34 LV installation manual

LaCie Network Space MAX Quick install guide

LaCie

LaCie Network Space MAX Quick install guide

ZoneVu ZSI-450-IP Installation guide & user manual

ZoneVu

ZoneVu ZSI-450-IP Installation guide & user manual

QNAP Turbo NAS Application notes

QNAP

QNAP Turbo NAS Application notes

OpenEye MV Series quick start guide

OpenEye

OpenEye MV Series quick start guide

Huawei SmartAX MT880a quick start guide

Huawei

Huawei SmartAX MT880a quick start guide

Proxim Tsunami QuickBridge 2454-R installation guide

Proxim

Proxim Tsunami QuickBridge 2454-R installation guide

Bay Networks CLAM quick start guide

Bay Networks

Bay Networks CLAM quick start guide

Innodisk SATADOM-SH 3SE Series manual

Innodisk

Innodisk SATADOM-SH 3SE Series manual

Cisco CGR 1000 Series Getting connected guide

Cisco

Cisco CGR 1000 Series Getting connected guide

Matrix Switch Corporation MSC-HD161DEL product manual

Matrix Switch Corporation

Matrix Switch Corporation MSC-HD161DEL product manual

National Instruments NI 653x user manual

National Instruments

National Instruments NI 653x user manual

B&B Electronics ZXT9-IO-222R2 product manual

B&B Electronics

B&B Electronics ZXT9-IO-222R2 product manual

Yudor YDS-16 user manual

Yudor

Yudor YDS-16 user manual

D-Link ShareCenter DNS-320L datasheet

D-Link

D-Link ShareCenter DNS-320L datasheet

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

DESCRIPTION
The Small Form-Factor Pluggable (SFP) Gigabit Ethernet,
Single-Fiber is a bidirectional SFP that plugs into the
Central Office Optical Loop Termination (OLT) designed
to accept SFPs. The SFP provides a single optical
interface to the GigE physical interface. Installed into an
appropriate OLT, the SFP provides a Gigabit Ethernet
tributary interface to the supporting system.
NOTE: To ensure compatibility, refer to the documentation
provided with the OLT.
The following features are supported on the SFP:
♦1000Base-LX 1490 nm Transmitter
♦1000Base-LX 1310 nm Receiver
♦Optical distance: 20 km maximum
CAUTION: Due to compliance certification requirements,
only SFPs supplied by ADTRAN should be used.
ADTRAN cannot certify system integrity with
other SFPs.
Operational Specifications
♦Optical Specifications:
– Optical transmit level: –8 dBm to –3 dBm
– Optical receive level: –22 dBm to –3 dBm
– Optical budget: 14 dB
– Optical connectors: LC
♦Extended Environmental Support:
– Operational temperature range: –40°C to +85°C
– Storage temperature range: –40°C to +85°C
– Relative humidity to 95%, noncondensing
INSTALLATION
To install the SFP into an appropriate module, complete
the following steps:
1. Inspect the SFP. If damaged, file a claim with the
carrier and then contact ADTRAN Customer Service.
2. Do not remove the protective end cap from the SFP
until the fiber optic cable is ready to be connected.
3. Insert the SFP into the SFP receptacle on the OLT.
Ensure the manufacturer’s label on the SFP is facing
upward for correct installation.
4. Slide the SFP all the way into the receptacle until
there is an audible “click”.
NOTE: The latch on the SFP is used to remove the SFP from
the cage on the circuit card.
5. Continue the installation and turn-up of the OLT
using the instructions in the Job Aid that
accompanied that OLT. The Installation and
Maintenance Practice (I&M) for the OLT is available
online at www.adtran.com.
CLEI: VAUIAL8P _ _
Product P/N: 1442120G1
Issue Date: 0802
Document P/N: 61442120G1-22A
Small Form-Factor Pluggable
Gigabit Ethernet, Single-Fiber 20 km
NOTE: The Gigabit Ethernet port(s) are optical and
therefore are not classified as any type of port as
defined in Appendix B of GR-1089-CORE Issue 4.
The SFP is designed to meet the following environmental
classes:
♦ETSI EN 300 019-1-1 “Classification of
environmental conditions; Storage,” Class 1.2
♦ETSI EN 300 019-1-2 “Classification of
environmental conditions, Transportation,” Class 2.3
♦ETSI EN 300 019-1-3 “Classification of
environmental conditions, Stationary use at weather-
protected locations,” Class 3.3
The equipment is designed to function without degra-
dation during exposure to all test severities per Class 3.3.
COMPLIANCE
CAUTION: Electrostatic Discharge (ESD) can damage
electronic modules. When handling modules,
wear an antistatic discharge wrist strap to
prevent damage to electronic components. Place
modules in antistatic packing material when
transporting or storing. When working on
modules, always place them on an approved
antistatic mat that is electrically grounded.
The SFP is NRTL Listed to the applicable UL
standards. The SFP meets or exceeds all the
applicable requirements of NEBS, Telcordia
GR-63-CORE, and GR-1089-CORE. The SFP is
intended for deployment in Central Office type
facilities, EEEs, EECs, and locations where the
NEC applies (for example, Customer Premises
and is intended to be installed by trained
service personnel). Install the SFP in an
ADTRAN product located in a restricted access
location.
This device complies with Part 15 of the FCC rules.
Operation is subject to the following two conditions:
1. This device may not cause harmful interference
2. This device must accept any interference received,
including interference that may cause undesired
operation.
Changes or modifications not expressly approved by
ADTRAN could void the user's authority to operate this
equipment.
CAUTION: Per GR-1089-CORE the ADTRAN system that
the SFP is being deployed in is designed and
intended for installation as part of a Common
Bonding Network (CBN). The ADTRAN system
that the SFP is being deployed in is not designed
nor intended for installation as part of an
Isolated Bonding Network (IBN).
Per GR-1089-CORE Section 9, the SFP does not
have an internal DC connection between battery
return and frame ground. The SFP can be
installed in a DC-I (isolated) or DC-C (common)
installation. For installations where other cards
or the host system have internal connections
between battery return and frame ground, the
system would be intended for deployment only
in a DC-C installation.
The ADTRAN system chassis frame ground
terminal must be connected to an earth ground to
ensure that the metal enclosure of the SFP is
properly grounded via the backplane connector.
Warranty: ADTRAN will replace or repair this product within the warranty period if it does not meet
its published specifications or fails while in service. Warranty information can be found
online at www.adtran.com/warranty.
© 2008 ADTRAN, Inc. All Rights Reserved.
*61442120G1-22A*
C A U T I O N !
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY.
HANDLING PRECAUTIONS REQUIRED.
CLEI: VAUIAL8P _ _
Product P/N: 1442120G1
Issue Date: 0802
Document P/N: 61442120G1-22A
PRICING AND AVAILABILITY 800.827.0807
TECHNICAL SUPPORT 800.726.8663
RETURN FOR REPAIR 256.963.8722
Small Form-Factor Pluggable
Gigabit Ethernet, Single-Mode 20 km