AECO SMC-12 NO M1 AGD2 Series User manual

www.aecosensors.com
YSM NNNNNN
SMC-12 NO M1 AGD2
YSM000023
SMC-12 NO M1 LC5 AGD2
YSM000024
SMC-12 NO M1 LC10 AGD2
YSM000025
SMC-12 NO M1 AGD2■
mm
mm
V
A
W/VA
Hz
°C
IP
> 6
NO
230
1.5
120
100
-25 ÷ +70
67
2 x 0.50mm² PVC
FM014Ex Rev. A
NO
ETC000471
80
CH17
M12x1
SMC-12 NO AGD
LC10
2
LC5
M1
Protect the input zone of the cable into the housing .from the light
BLUE
BROWN
Sensing distance (Sn)
Hysteresis (’’H’’)
Max switching voltage
Ambient temperature range
IP rating
Housing material
Cable
Output type
Max switching current
Max switching power
Max switching frequency
> 10 with M20 magnet
Nickel-plated Brass
2mt, 5mt or 10mt
WIRING DIAGRAM
Characteristics
Models
Dimensions ‘’mm’’
4. Electrical and Mechanical Characteristics
( Description )( Code )
3.3 Product series
The magnetic sensors series includes the
models listed below :
SMC-12 NO M1 AGD2■
Potentially explosive atmosphere
with GAS and/or DUST.
Cable length "2mt".
Cable length "5mt".
Cable length "10mt".
Equipment category "2"
Magnetic Sensor with cylindrical housing
"M12x1" and "NORMALLY OPEN" output
3.2 Description diagram
3.1 Code diagram
Magnetic sensor intended for use in the explosive atmospheres
according to EU Directive ATEX 94/9 EC.
Progressive number
3. Sensor identification
The series is only identified by the '' ''
and '' ''. The diagrams for the decoding are shown below.
Code
Description
SMC-12 NO M1 AGD2■
1. Introduction
This manual should be read and understood in all its parts before proceeding
with installation of the sensor.
The Magnetic Sensors series, are intended to be
used in a potentially explosive atmospheres with presence of GAS and/or
DUST. They are designed and produced according to the requirements of the
following european standards:
* EN60079-0 - Explosive atmospheres - Part 0 : Equipment - General requi-
rements.
* EN60079-18 - Explosive atmospheres - Part 18 : Equipment protection by
encapsulation ‘’m’’.
All sensors of this series are covered by the EC-type Examination Certificate
n ° IMQ 12 ATEX 016X issued by Notified Body IMQ spa.
SMC-12 NO M1 AGD2
■
2. Installation and Startup
The sensor must be installed, connected and activated only by specialized
personnel. Personnel must be familiar with the types of protection
anti-ignition, the production rules and regulations in the potentially explosive
area. The user is solely responsible for the choice and the use of sensor
suitable to the final application. When installing the sensor observe the
following requirements:
Check whether the classification of the sensor is suitable for the application
(see‘’ATEX Marking’’ to paragraph 5 and marking on the equipment).
Make sure that the connection cable of the sensor does not have the
endings too tight. Moreover it must not prevent the movement of people
and/or things.
Do not touch uninsulated parts of the connecting cable of the sensor before
having it disconnected from the supply voltage. Do not install the sensor
during a thunderstorm with lightning.
If the cable is subject to movement, do not place the sheath with bending
radius too short; Pay attention to the mounting of the parties subject to
movement and to the fixed ones.
Separate the power cables from the connecting cable of the sensor.
Make sure that the sensor housing is always ground wired.
Operating Instructions
According to EU Directive 94/9 EC ( ATEX )
Annex VIII group II, equipment category 2G/2D
GB
Reed Contact model: Vmax = 230Vac/dc
Imax = 1.5A
Pmax= 120W/VA
Sig. M. Scaramuzza
Fig. 2
II 2D Ex mb IIIC T85°C Db IP67
II 2G Ex mb IIC T6 Gb Ta= -25 ÷ +70°C
0722
YSM000023
YSM000024
YSM000025
SMC-12 NO M1 AGD2
SMC-12 NO M1 LC5 AGD2
SMC-12 NO M1 LC10 AGD2
Via G. Leopardi 5 - 20065 Inzago ( MI ) Italia
DIC15414EX REV. 01
II 2D Ex mb IIIC T85°C Db IP67
II 2G Ex mb IIC T6 Gb
BROWN
BLUE
SMC-12 NO M1 AGD2■
V= 230V I= 1.5A P= 120W/VA
Tamb: -25 ÷ +70°C
88888
0722
II 2G Ex mb IIC T6 Gb
II 2D Ex mb IIIC T85°C Db IP67
AECO Inzago-MI-Italy
IMQ 12 ATEX 016X
Fig. 1
NO
Fp
EC-Type Examination
Certificate number
Inzago: 2014/11/27
( Place and Date )
( Name and Signature )
( Description )( Code )
2006/95/CE - Low Voltage Directive
94/9/EC - ATEX Directive - GROUP CATEGORY EXPLOSIVE ATMOSPHERES
WITH PRESENCE OF GAS AND/OR THE
PRESENCE OF DUST
“II”
“G” ( )
“D” ( )
’’2”
ZONE 1
ZONE 21
MARKING :
( Title and / or number and date of issue of the standard )
according to the provisions of the European Directives:
EN 60079-0
August 2009
EN 60947-1
July 2007
EN 60947-5-1
June 2004
EN 60079-18
December 2009
to which this declaration relates are in conformity with the following standards:
declare under our sole responsibility that the products:
(Product’s name )
MAGNETIC SENSORS
DECLARATION OF CONFORMITY
9. Declaration of Conformity
We, AECO s.r.l.
( Supplier’s name )
( Supplier’s address )
8. Maintenance
The sensor has no serviceable components and can not be changed and / or
repaired. In case of failure, please contact AECO srl customer service.
If necessary, you can ask AECO srl for a copy of the following
documents :
Sensor Data Sheet
Declaration of Conformity
You can also download the same documents from AECO web site
( ).
www.aecosensors.com
Production batch
ATEX Marking
Ambient temperature range
‘’Model’’ description
Electrical parameters
Wiring diagram
7. Labelling
On every sensor of the '' ''
is applied as shown in Fig. 2 :
SMC-12 NO M1 AGD2■series a label
Temperature class for GAS
Indicates the maximum surface temperature that can reach the sensor
at the maximum ambient temperature according to EN60079-0.
T6 Maximum surface temperature : 85 ° C
Maximum Surface Temperature for DUST
Indicates the maximum surface temperature that can reach the sensor
at the maximum ambient temperature according to EN60079-0.
T85 Maximum surface temperature : 85 ° C
Equipment Protection Level (EPL) for GAS
Indicates the level of protection of the equipment according to
:EN60079-18
Gb Equipment with protection level ' 'mb
Equipment Protection Level (EPL) for DUST
Indicates the level of protection of the equipment according to
:EN60079-18
Db Equipment with protection level ' 'mb
6. Conditions of use in potentially explosive area.
During the use of the sensor in potentially explosive atmosphere observing
the following instructions is important for safety :
The maximum permissible ambient temperature is Ta = +70 °C
Protect the sensor from damage due to shock and vibration
5. ATEX marking
ZONE 1 and ZONE 2 (Atmosphere with GAS)
ZONE 21 and ZONE 22 ( DUST)Atmosphere with
for use in
For all models '' '' refere to the ATEX marking
below indicated :
SMC-12 NO M1 AGD2■
The meaning of the symbols that make the marking is as follows:
Specific mark. Protection against explosion
II
Equipment group.
Category group.
2
Equipment suitable for use in all other places other than mines and
their surface installations.
GAtmosphere due to the presence of , and .gases vapors mists
DAtmosphere due to the presence of dust
Ex Equipment designed for use in potentially explosive atmospheres
Type of explosive atmosphere
mb
Type of protection
Encapsulation protection level according to .EN60079-18''mb''
Explosion group GAS
Specifies the explosion group wich the type of GAS belongs to,
according to EN 60079-20.
IIC The typical GAS of this group is the hydrogen
Explosion group DUST
IIIC Conductive dust
Specifies the explosion group wich the type of DUST belongs to,
according to EN 60079-0.
Equipment designed for use in places where
(10 to 100h/year) (ZONE 1 or ZONE 21).
an explosive atmosphere
is not constantly present
BROWN
BLUE
Signal
Signal
Sensor Field
Protection Fuse
Fp =
Inf (A)= 1A
(Fuse nominal current)
Vnf (V)=230Vac
(Fuse nominal voltage)
Rupture capacity
1500A
It is necessary to protect the circuit by connecting in series to the sensor
a non resettable fast-acting fuses with the following ratings :

This manual suits for next models

6

Other AECO Accessories manuals

AECO SMS88-P5 2NC H1C PL User manual

AECO

AECO SMS88-P5 2NC H1C PL User manual

AECO SMC-12 NO AGD3 User manual

AECO

AECO SMC-12 NO AGD3 User manual

AECO SMC-12 NO SS BC HF AGD1 Series User manual

AECO

AECO SMC-12 NO SS BC HF AGD1 Series User manual

AECO SMC-12LM NO AGD3 Series User manual

AECO

AECO SMC-12LM NO AGD3 Series User manual

AECO AGD3 Series User manual

AECO

AECO AGD3 Series User manual

Popular Accessories manuals by other brands

dtm Azymut Installation and operating manual

dtm

dtm Azymut Installation and operating manual

weinor WGM 2030 Design Maintenance instructions and directions for use

weinor

weinor WGM 2030 Design Maintenance instructions and directions for use

Endress+Hauser Proline 100 Modbus RS485 Brief operating instructions

Endress+Hauser

Endress+Hauser Proline 100 Modbus RS485 Brief operating instructions

Campbell TempVue 10 product manual

Campbell

Campbell TempVue 10 product manual

Campbell CS511 product manual

Campbell

Campbell CS511 product manual

Simrad PI32 Quick reference guide

Simrad

Simrad PI32 Quick reference guide

Servodan 41-270 Fitting and operating instructions

Servodan

Servodan 41-270 Fitting and operating instructions

Enerwave ZWN-BDS-PLUS installation instructions

Enerwave

Enerwave ZWN-BDS-PLUS installation instructions

Shadesign SHADEONE Technical data sheet

Shadesign

Shadesign SHADEONE Technical data sheet

Cairpol Cairsens Use guide

Cairpol

Cairpol Cairsens Use guide

Panasonic MA24F41 Specification sheet

Panasonic

Panasonic MA24F41 Specification sheet

Modine Manufacturing PD/BD installation instructions

Modine Manufacturing

Modine Manufacturing PD/BD installation instructions

Panlux SL2504/B instructions

Panlux

Panlux SL2504/B instructions

Sensio Sparia instruction manual

Sensio

Sensio Sparia instruction manual

GTV PC-ELE724-00 Assembly instruction

GTV

GTV PC-ELE724-00 Assembly instruction

Cisco UCS 6248 UP installation guide

Cisco

Cisco UCS 6248 UP installation guide

Wenglor OPT2170 operating instructions

Wenglor

Wenglor OPT2170 operating instructions

Stobag SKIROSOL SRCK 620 Instructions and warnings for installation and use

Stobag

Stobag SKIROSOL SRCK 620 Instructions and warnings for installation and use

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.