BROWN
BLUE
SMC-12 NO AGD3■
V= 230 V I= 0.5 A P= 50 W/VA
Tamb: -25 ÷ +70°C
II 3G Ex mc IIC T6 Gc
II 3D Ex mc IIIC T85°C Dc
AECO Inzago-MI-Italy
Fig. 1
2016 12345
IP67
9. EU Declaration of Conformity
7. Maintenance
The sensor has no serviceable components and can not be changed and / or
repaired. In case of failure, please contact customer service.AECO srl
If necessary, you can ask for a copy of the following documents :AECO srl
You can also download the same documents from web site
( ).
AECO
www.aecosensors.com
Production batch
ATEXmarking
Ambient temperature range
‘’Model’’ description
Electrical parameters
Wiring diagram
8. Labelling
On every sensor of the '' '' is applied
as shown in Fig. 1 :
SMC-12 NO AGD3■series a label
Temperature class for GAS
Indicates the maximum surface temperature that can reach the sensor
at the maximum ambient temperature according to EN 60079-0.
T6 Maximum surface temperature : 85 °C
Maximum Surface Temperature for DUST
Indicates the maximum surface temperature that can reach the sensor
at the maximum ambient temperature according to EN60079-0.
T85 Maximum surface temperature : 85 ° C
Equipment Protection Level (EPL) for GAS
Indicates the level of protection of the equipment according to
EN 60079-18.
Gc Equipment with protection level ' 'mc
Equipment Protection Level (EPL) for DUST
Indicates the level of protection of the equipment according to
EN 60079-18.
Dc Equipment with protection level ' 'mc
6. Conditions of use in potentially explosive area.
During the use of the sensor in potentially explosive atmosphere observing
the following instructions is important for safety :
The maximum permissible ambient temperature is Ta = +70 °C
To protect the sensor from damage due to shock and vibration
5. ATEX marking
ZONE 2 (Atmosphere with GAS)
ZONE 22 ( DUST)Atmosphere with
for use in
For all models '' '' refere to the ATEX marking below
indicated :
SMC-12 NO AGD3■
The meaning of the symbols that make the marking is as follows:
Specific mark. Protection against explosion
II
Equipment group.
Category group.
3Equipment designed for use in places where
(ZONE 2 or ZONE 22).
an explosive atmosphere
is present rarely or for short periods
Equipment suitable for use in all other places other than mines and
their surface installations.
GAtmosphere due to the presence of , and .gases vapors mists
DAtmosphere due to the presence of dust
Ex Equipment designed for use in potentially explosive atmospheres
Type of explosive atmosphere.
mc
Type of protection
Encapsulation protection level according to .EN 60079-18''mc''
Explosion group GAS
Specifies the explosion group which the type of GAS belongs to,
according to .EN 60079-20
IIC An typical GAS of this group is the hydrogen
Explosion group DUST
IIIC Conductive dust
Specifies the explosion group which the type of DUST belongs to,
according to EN 60079-0.
II 3D Ex mc IIIC T85°C Dc
II 3G Ex mc IIC T6 Gc
Sensor data sheet
EU Declaration of Conformity
IP protection grade
Manufacture year
declare under our sole responsibility that the products:
EU Declaration of Conformity
Product’s name: Magnetic Sensors
Models: SMC-12 NO AGD3
ATEX Marking:
II 3G Ex mc IIC T6 Gc
II 3D Ex IIIC T85°C Dcmc
Inzago: 2016.09.01 Maurizio Scaramuzza
We AECO s.r.l.
Via G. Leopardi 5, 20065 Inzago (MI), Italy
2014/34/EU - ATEX Directive
2014/35/EU - Low voltage Directive
Legal representative
CUE057EX REV. A
-25°C Ta +70°C< <
EN60079-0:2012 + A11:2013
EN60079-18:2015
EN 60947-1 : 2007
EN 60947-5-1 : 2004
and are comply with the following armonized standards
to which this declaration relates, meet the requirements of the european directives
SMC-12 NO AGD3■( LC5 LC10■= or )