manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Agni
  6. •
  7. Security Sensor
  8. •
  9. Agni AGNI-203 User manual

Agni AGNI-203 User manual

CONVENTIONAL HEAT' DETECTOR
AGNI-203
A G N I ’ C O N V E N T I O N A L H E AT
DETECTOR is a device with advanced
technology and feature that detects rate
of rise of temperature. It does not operate
without electrical power. The special
feature of this detector is dual
thermistors. One is sealed and the other
is exposed. In the event of fire, the
exposed thermistor reacts quickly to rate
of rise and fixed temperature. When a
specific temperature is reached, due to
variation of temperature in both the
thermistors, the detector automatically
switches over into alarm mode and
invokes the fire alarm.
Features.....
?Easy installation and maintenance
?Sleek low-profile housing design.
?Algorithm map for faster detection and
discrimination
?Algorithm map for false alarm rejection
?Built-in 32 Bit Microprocessor
?Built-in Remote Indicator output
?EN54compliance
?LED for 360° visibility
?Sensing chamber for dust proof ability
?To ensure constant sensitivity
provision of drift compensation.
TECHNICAL DATA SHEET
PARAMETER DATA
Agni Instruments Engineers (I) Pvt. Ltd.
AGNI-203
58°C
10mA ≤i ≤30mA
(2s Min, 2.5VDC Max)
-10°C ~ +50°C
Dia : 100mm; H : 41.8mm (w/o base)
Red Flashes periodically (2s~4s) in polling,
illuminates in alarming.
IP-23
2V (peak-to-peak)
ABS ; White
45mm ~ 75mm
9VDC-34VDC
s10s
≤95%;non-condensing
Directly connecting with remote indicator
(built-in 2k resistor In series. Output
voltage 5V). Do not illuminate when
in polling. Illuminate in alarming.
3°C/min.
≤60 ìa
1. Make
2. Model
3. Action Temperature
4. Alarm Current
5. Alarm Reset Instantaneous Cut out
6. Ambiant Temp.
7. Dimension
9. Fire LED:
10. Ingress Protection Rating
11. Maximum Ripple Voltage
12. Material and color of enclosure
13. Mounting hole spacing
14. Operating Voltage
15. Power-up Time
16. Relative Humidity
17. Remote Indication Output
18. Response Velocity
19. Standby Current
20. Weight
21. Wiring:
about 120 g
Two-wire ; Polarity sensitive
Y-51, OKHLA INDUSTRIAL AREA PAHSE.-II NEW DELHI 110020 (INDIA)
L1 IN
R1
L2
L1IN
R1
L2
L1 IN
R1
L2
END OF LINE DEVICE
REMOTE INDICATOR
FACP
+VE
-VE
L1 IN
R1
L2
L1 IN
R1
L2
L1 IN
R1
L2
END OF LINE DEVICE
COM. REMOTE INDICATOR
FACP
+VE
-VE
Schematic Wiring Diagram of AGNI-205 (Base) Monitored Detector Circuit With Remote Indicator.
Schematic Wiring Diagram of (Base) Monitored Detector Circuit With Common Remote Indicator.AGNI-205
WIRING DIAGRAM
COMPATIBILITY
DETECTOR BASE
INSTALLATION
AGNI Conventional Heat Detector are compatible with all type of Conventional Semi
Addressable andAddressable (using module) FireAlarm Control Panels.
The AGNI-205 Base made of ABS Plastic, is a conductive base. It has one way locking
mechanism with the detector. The flame class is V-0, The base is required to be fixed before
connecting cables and mounting of Detector.
Technical Specification:-
Operating Temperature (Environmental) : 10C + 50C
Relative Humidity : <95% No condensation
Height : 16mm
Diameter : 100mm
Colour : White
Material : ABS
?As the detector dose not operate without electrical power, it is advised to check regularly and
ensure that there is no interruption of power supply to the device.
?The detector should be stored within the recommended range and allowed to stabilize to
room temperature before applying power for successful operation.
?Installation of the device should be carried out as described in the installation sheet.
?Detector should be installed in compliance with Bs5389 Part 1 and En54.
?check the wiring and fix the base of the detector firm to the roof/wall.
?Fix the detector in the base by the mark-line and rotate the detector clockwise until it reaches
the locked position and ensure that it is tightly fixed to the base.
?Till completion of installation, do not remover the red plastic dust cover.
?Calibration sensitivity test per NFPA code is required to be carried out once the installation of
device is complete.
Y-51, OKHLA INDUSTRIAL AREA PAHSE.-II NEW DELHI 110020 (INDIA)

Popular Security Sensor manuals by other brands

Satel VD-1 user manual

Satel

Satel VD-1 user manual

Leica DIGICAT 500i quick start

Leica

Leica DIGICAT 500i quick start

Emos G1160 quick start guide

Emos

Emos G1160 quick start guide

SMART ALCO AL-80523 Installation and use instructions and warnings

SMART

SMART ALCO AL-80523 Installation and use instructions and warnings

Ametek Ortec radEAGLET-R Series user manual

Ametek

Ametek Ortec radEAGLET-R Series user manual

REED R9300 instruction manual

REED

REED R9300 instruction manual

Yale EF-PETPIR manual

Yale

Yale EF-PETPIR manual

SICK deTem4 Core Ex operating instructions

SICK

SICK deTem4 Core Ex operating instructions

Radiodetection 1205CXB Operation manual

Radiodetection

Radiodetection 1205CXB Operation manual

Dilo SF6 operating manual

Dilo

Dilo SF6 operating manual

Besantek BST-HVD9 instruction manual

Besantek

Besantek BST-HVD9 instruction manual

Emerson Rosemount CT4215 Reference manual

Emerson

Emerson Rosemount CT4215 Reference manual

Leviton decora IPV05 installation instructions

Leviton

Leviton decora IPV05 installation instructions

König SAS-DVRPIR10 manual

König

König SAS-DVRPIR10 manual

Monacor SMILE-16 operating instructions

Monacor

Monacor SMILE-16 operating instructions

Velleman DVMEMF user manual

Velleman

Velleman DVMEMF user manual

PCE Instruments PCE-GA 10 user manual

PCE Instruments

PCE Instruments PCE-GA 10 user manual

Gossen MetraWatt Camille Bauer CableCop 300 operating instructions

Gossen MetraWatt

Gossen MetraWatt Camille Bauer CableCop 300 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.