manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Agni
  6. •
  7. Security Sensor
  8. •
  9. Agni AGNI-203 User manual

Agni AGNI-203 User manual

Popular Security Sensor manuals by other brands

Honeywell Home PROSiXCOCN Installation and setup guide

Honeywell Home

Honeywell Home PROSiXCOCN Installation and setup guide

Duevi SIRPZ-RB-868 Operation

Duevi

Duevi SIRPZ-RB-868 Operation

RKI 65-2483RK Operator's manual

RKI

RKI 65-2483RK Operator's manual

Nortech PD160 Enhanced Series user manual

Nortech

Nortech PD160 Enhanced Series user manual

Omron K8AC-H2 manual

Omron

Omron K8AC-H2 manual

Agilent Technologies G8610 Series Quick reference card

Agilent Technologies

Agilent Technologies G8610 Series Quick reference card

Shinko SE2EA-1-0-0 instruction manual

Shinko

Shinko SE2EA-1-0-0 instruction manual

Det-Tronics X Series instructions

Det-Tronics

Det-Tronics X Series instructions

ACR Electronics COBHAM RCL-300A Product support manual

ACR Electronics

ACR Electronics COBHAM RCL-300A Product support manual

TOOLCRAFT 1712612 operating instructions

TOOLCRAFT

TOOLCRAFT 1712612 operating instructions

Elkron IM600 Installation, programming and functions manual

Elkron

Elkron IM600 Installation, programming and functions manual

Bosch WEU PDO 6 Original instructions

Bosch

Bosch WEU PDO 6 Original instructions

THORLABS PDA10JT user guide

THORLABS

THORLABS PDA10JT user guide

Waeco UV-DETECT operating manual

Waeco

Waeco UV-DETECT operating manual

Intermatic IOS-DSIMF manual

Intermatic

Intermatic IOS-DSIMF manual

Siemens AZL66 Series manual

Siemens

Siemens AZL66 Series manual

BTI Profiline Multi Finder operating instructions

BTI

BTI Profiline Multi Finder operating instructions

Challenger SL01 instruction manual

Challenger

Challenger SL01 instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

CONVENTIONAL HEAT' DETECTOR
AGNI-203
A G N I ’ C O N V E N T I O N A L H E AT
DETECTOR is a device with advanced
technology and feature that detects rate
of rise of temperature. It does not operate
without electrical power. The special
feature of this detector is dual
thermistors. One is sealed and the other
is exposed. In the event of fire, the
exposed thermistor reacts quickly to rate
of rise and fixed temperature. When a
specific temperature is reached, due to
variation of temperature in both the
thermistors, the detector automatically
switches over into alarm mode and
invokes the fire alarm.
Features.....
?Easy installation and maintenance
?Sleek low-profile housing design.
?Algorithm map for faster detection and
discrimination
?Algorithm map for false alarm rejection
?Built-in 32 Bit Microprocessor
?Built-in Remote Indicator output
?EN54compliance
?LED for 360° visibility
?Sensing chamber for dust proof ability
?To ensure constant sensitivity
provision of drift compensation.
TECHNICAL DATA SHEET
PARAMETER DATA
Agni Instruments Engineers (I) Pvt. Ltd.
AGNI-203
58°C
10mA ≤i ≤30mA
(2s Min, 2.5VDC Max)
-10°C ~ +50°C
Dia : 100mm; H : 41.8mm (w/o base)
Red Flashes periodically (2s~4s) in polling,
illuminates in alarming.
IP-23
2V (peak-to-peak)
ABS ; White
45mm ~ 75mm
9VDC-34VDC
s10s
≤95%;non-condensing
Directly connecting with remote indicator
(built-in 2k resistor In series. Output
voltage 5V). Do not illuminate when
in polling. Illuminate in alarming.
3°C/min.
≤60 ìa
1. Make
2. Model
3. Action Temperature
4. Alarm Current
5. Alarm Reset Instantaneous Cut out
6. Ambiant Temp.
7. Dimension
9. Fire LED:
10. Ingress Protection Rating
11. Maximum Ripple Voltage
12. Material and color of enclosure
13. Mounting hole spacing
14. Operating Voltage
15. Power-up Time
16. Relative Humidity
17. Remote Indication Output
18. Response Velocity
19. Standby Current
20. Weight
21. Wiring:
about 120 g
Two-wire ; Polarity sensitive
Y-51, OKHLA INDUSTRIAL AREA PAHSE.-II NEW DELHI 110020 (INDIA)
L1 IN
R1
L2
L1IN
R1
L2
L1 IN
R1
L2
END OF LINE DEVICE
REMOTE INDICATOR
FACP
+VE
-VE
L1 IN
R1
L2
L1 IN
R1
L2
L1 IN
R1
L2
END OF LINE DEVICE
COM. REMOTE INDICATOR
FACP
+VE
-VE
Schematic Wiring Diagram of AGNI-205 (Base) Monitored Detector Circuit With Remote Indicator.
Schematic Wiring Diagram of (Base) Monitored Detector Circuit With Common Remote Indicator.AGNI-205
WIRING DIAGRAM
COMPATIBILITY
DETECTOR BASE
INSTALLATION
AGNI Conventional Heat Detector are compatible with all type of Conventional Semi
Addressable andAddressable (using module) FireAlarm Control Panels.
The AGNI-205 Base made of ABS Plastic, is a conductive base. It has one way locking
mechanism with the detector. The flame class is V-0, The base is required to be fixed before
connecting cables and mounting of Detector.
Technical Specification:-
Operating Temperature (Environmental) : 10C + 50C
Relative Humidity : <95% No condensation
Height : 16mm
Diameter : 100mm
Colour : White
Material : ABS
?As the detector dose not operate without electrical power, it is advised to check regularly and
ensure that there is no interruption of power supply to the device.
?The detector should be stored within the recommended range and allowed to stabilize to
room temperature before applying power for successful operation.
?Installation of the device should be carried out as described in the installation sheet.
?Detector should be installed in compliance with Bs5389 Part 1 and En54.
?check the wiring and fix the base of the detector firm to the roof/wall.
?Fix the detector in the base by the mark-line and rotate the detector clockwise until it reaches
the locked position and ensure that it is tightly fixed to the base.
?Till completion of installation, do not remover the red plastic dust cover.
?Calibration sensitivity test per NFPA code is required to be carried out once the installation of
device is complete.