SATEL VD-1 3
15 mm
A
15 mm
B
Fig. 3. Max. operation ranges of the reed switches (top view). The indicated ranges are valid
for the magnet situated in the presented position, at the height of detector electronics board.
2. Initializing
1. Power on the detector. If the jumper on the LED pins is set in the ON position, the LED
will indicate by flashing the number of pulses set for the vibration detector.
2. Define the operating parameters of the vibration detector (using potentiometers indicated
in Figure 1 by numbers 1 and 2) and magnetic contact (using pins indicated in Figure 1 by
numbers 9 and10).
3. Make sure that the detector responds properly to the vibrations. If necessary, change the
sensitivity or the number of pulses.
4. If the magnetic contact has been turned on, check that it responds properly to moving the
magnet away from the selected reed switch.
3. Technical Data
Supply voltage................................................................................................... 12 V DC ±15%
Current consumption, stand-by.......................................................................................3.5 mA
Current consumption, max..............................................................................................5.4 mA
Permissible switching capacity of relay switches (resistive load)....................40 mA / 16 V DC
Approx. operation range of vibration detector, depending on mounting surface:
concrete...........................................................................................................1.5 m
brick.................................................................................................................2.5 m
wood................................................................................................................3.5 m
steel....................................................................................................................3 m
PVC ...............................................................................................................2.25 m
Environmental class.................................................................................................................II
Operating temperature range..................................................................................-10...+55 °C
Enclosure dimensions....................................................................................24 x 110 x 27 mm
Weight.................................................................................................................................44 g