Aiphone MC-60/4A User manual

0496®
©
AIPHONE
INSTALLATION
&
OPERATION
MANUAL
1
SYSTEM
OUTLINE
&
COMPONENTS-
The
MC-60/4
is
a
paging
and
communication
system
designed
for
retail
stores,
factories,
and
warehouses.
The
Market-Corn
locates
individuals
quickly
through
paging,
and
has
two-way
communication
between
any
station
in
the
system.
The
system
is
equipped
with
4
communication
channels,
capacity
of
up
to
60
stations,
and
incorporates
paging
and
background
music.
MC-60/4A
.
MC-60/4A
(max.
10)
Paging
system
(max.
10)
■
Components
available
•
For
MC-60/4A;
MCS-12:
12”
checkstand
pedestal
(US
only)
MCS-23:
23”
checkstand
pedestal
(US
only)
MC-S6:
Desk
stand
for
MC-60/4A
(1
pee
per
MC-60/4A
as
required)
•
For
paging
&
music;
PG-20C:
Paging
amplifier,
20W,
wall
mount
with
built-in
paging
adaptor
(US
only)
PG-50C:
Paging
amplifier,
50W,
wall
mount
with
built-in
paging
adaptor
(US
only)
PG-100C:
Paging
amplifier,
100W,
wall
mount
with
built-in
paging
adaptor
(US
only)
SP-5N:
Ceiling
speaker,
70V,
4W
(US
only)
SSB-2:
Ceiling
support
bracket
for
SP-5N
AH-16TN:
Horn
speaker,
70V,
16W
(US
only)
AH-32TN:
Horn
speaker,
70V,
32W
(US
only)
-1
-

NAMES
&
FEATURES
MC-60/4A
1
2
6
3
4
5
6
1
Handset
2
PAGE
button
3
Channel
occupied
LED
(4)
Ch.1.Red
Ch.2.Green
Ch.3.Yellow
Ch.4.Orange
4
Handset
cradle
5
Channel
selector
button
(4)
6
Jack
(4
cond.)
MC-60/4B
1
Terminal
box
w/1,5m,
,5’
cord
2
Channel
occupied
LED
(4)
Ch.1
...
...Red
Ch.2...
...Green
Ch.3...
...Yellow
Ch.4...
...Orange
Channel
selector
button
(4)
■
Features
•
Max.
60
stations
per
system
•
4
communication
channels
i
•
Easy-to-run
7
conductor
cable
throughout
the
system,
wired
in
blocks
of
up
to
10
stations
per
block
from
adaptor/amplifier
•
Illuminated
LED
indicates
which
channel
is
being
used
•
Conference
calling
for
up
to
3
stations
•
Background
music
can
be
incorporated
•
Automatic
music
muting
during
announcement
•
Phone
style
coil
cord
with
reinforced
jacks
(MC-60/4A)
•
Durable
handset
cradle

3
PRECAUTIONS
ON
INSTALLATION
&
WIRING-
★
Do
not
attempt
to
install
or
connect
wires
on
MC-60/4
equipment
while
system’s
power
supply
is
turned
on.
★
MC-60/4
masters
and
related
equipment
are
designed
for
indoor
use
only.
Do
not
install
outdoors.
★
Do
not
connect
any
other
power
source
than
specified
on
terminals
1/+
and
5/-.
Doing
so
can
damage
the
MC-60/4
equipment.
★
Do
not
open
any
MC-60/4
system
components.
Ask
qualified
personnel.
★
All
the
products
of
other
manufacturers,
power
supply,
buzzer,
etc.
used
for
MC-60/4
are
not
within
our
warranty,
and
must
be
used
under
manufacturer
or
distributor’s
specifications
and
warranty.
★
Do
not
mount
MC-60/4
equipment
in
the
following
places,
as
it
may
cause
the
system
to
malfunction:
•
High
or
extreme
cold
temperature
areas:
under
direct
sunlight,
near
equipment
that
varies
in
temperature,
near
an
air-conditioner,
inside
refrigerating
warehouse,
etc.
•
Places
subject
to
moisture
or
humidity
extremes.
•
Places
subject
to
environmental
conditions,
such
as
dust,
oil
and
chemicals,
etc.
★
MC-60/4
is
an
electrical
appliance,
which
must
not
be
subjected
to
water
and
or
any
other
liquid.
★
Weather
conditions,
such
as
lightning
storms,
may
cause
damage
to
MC-60/4
equipment.
It
is
suggested
to
take
protective
measures
as
follows;
•
When
a
DC
power
supply
is
used:
On
the
power
supply
with
grounding
terminal,
be
sure
to
take
the
terminal
to
earth
ground.
In
this
case,
it
is
not
necessary
to
connect
a
surge-arrester.
•
If
no
grounding
terminal
is
available,
install
the
SA-1
surge
arrester
on
the
power
supply
line.
■
Before
MC-60/4
is
actually
installed,
the
contents
of
this
Manual
must
be
thoroughly
read
and
understood.
WIRING
■
Actual
Terminal
Location
MC-60/4
A
Chassis
inside
view
MC-60/4B
Terminal
box
inside
view
Connect
all
number
terminals
in
parallel
from
station
to
station.
1
Power
supply
(+24V
DC)
2
Paging
signal
3
Talk
channel
2
4
Talk
channel
1
5
Power
supply
(-24V
DC)^
6
Talk
channel
3
7
Talk
channel
4
★
When
more
than
7
conductor
cable
is
used,
connect
extra
wires
on
5
terminal
to
avoid
crosstalk.
-
3
-

Wiring
diagram
Paging
SP.
Paging
K
amp.
Q_0_
□
Music
source
MC-A/A
PS-24N
MC-60/4A
MC-60/4B
7
(f
MC-A/A
Adaptor
MC-A/A
is
built
into
PG-C
amp.
,_,
Shielded
A
-nrir
DO
-
'
'
x
h
-
G
Shielded
E
Music
source
Paging
Amp.
PG-10A,
etc.
Ai^--1
Paging
speakers
★
Keep
MUSIC
INPUT
&
PAGING
OUTPUT
lines
well
separated.
If
run
closely
together,
feedback
may
occur.
PS-24N
Power
Supply
★
T
aking
GND
to
earth
may
help
to
avoid
noise
during
communication.
1st
phone
block
(up
to
10
stations)
2nd
phone
block
Up
to
6
blocks
r
1
2
q
o
A
4
5
6
7
f
1
■
2
■
3
■
4
-
.
C
r~
v
\
\
\
\\
A
A
D
■
6
■
-
7
-
A
k\\\
A
\\\\\[
{_
1
■
2
-
3
-
4
■
-
5
■
-
6
-
■
7
-
\
f
J
s
—
..
1
-
2
-
3
-
4
-
■
5
-
■
6
-
-
7
-
\
/—
-J
V
J
MC-60/4A
MC-60/4A
★
W
h
en
using
PG-C
Amplifiers;
MC-60/4
PG-C
“
8
“
7
“
9
4
“
3
-
1
-
2
-
4
-
1
3
-—-
/
Music
cond.
2
-
)
Tel/Mic
Paging
★
S
et
dip
switch
7
to
ON
position
and
switch
8
to
OFF
position.
-
4
-

MOUNTING
Mounting
guidelines
The
MC-60/4A
is
designed
for
wall
or
pedestal
mounting
only.
1.
Loosen
screw
on
the
bottom
of
the
front
case,
and
remove
the
unit
by
sliding
the
front
case
upward
from
the
back
chassis,
then
pull
away.
Disconnect
the
intercom
from
the
back
chassis
by
unplugging
the
multi-pin
connector.
Do
not
force
the
unit
open.
(Set
the
intercom
unit
aside
while
making
wire
terminations
so
as
not
to
mar
or
scratch
the
unit.)
2.
Install
the
back
chassis
to
a
single
gang
box
or
mounting
ring,
or
directly
to
the
wall.
3.
All
wiring
terminations
are
done
on
the
back
chassis
directly
onto
the
screw
terminal
section.
Designate
a
color
code
for
wire
numbers
1-7,
and
connect
wires
accordingly.
Connect
all
like
terminals
together
with
matching
wires.
4.
Wiring
is
done
in
a
daisy-chained
method
with
up
to
10
stations
on
a
run.
5.
When
wiring
is
completed,
reattach
the
intercom
to
the
back
chassis
by
plugging
in
the
multi-pin
connector.
Align
from
the
top
and
slide
downward
into
position.
Tighten
screw
at
the
bottom
of
the
front
case.
MC-60/4A
MC-60/4B
★
Install
terminal
box
and
cable
in
non-trapping
manner.
>
OPERATIONS---
When
an
LED
at
the
top
of
the
station
is
lit,
that
channel
is
in
use.
Select
another
channel
that
is
not
in
use.
When
any
one
station
has
a
channel
selected,
the
corresponding
LED
will
be
lit
on
all
other
stations.
If
responding
to
a
call,
select
the
station
number
that
was
requested
by
the
person
paging.
•
Calling
•
When
being
paged
•
Conference
calling
•
Music
muting
Select
the
channel
number
(1-4).
Page
&
request
a
person
to
join
in
on
a
selected
channel.
Release
PAGE
button
and
wait
for
reply.
Go
to
the
nearest
MC-60/4
station,
and
select
the
channel
you
were
requested
on.
Call
for
up
to
2
persons
to
a
conference
call
on
your
selected
channel.
If
more
than
3
people
join
in,
communication
volume
may
be
affected.
When
a
station
starts
paging,
pretone
will
sound
and
the
music
will
be
muted.
When
the
page
is
completed,
the
music
will
return.
★
Firmly
depress
channel
number
button
in
every
operation.
Depress
Release
-
5
-

TECHNICAL
PRECAUTIONS-
★
Make
wiring
blocks
in
a
manner
that
wiring
length
of
any
two
blocks
added
together
does
not
exceed
1,700’
w/
22AWG
either.
Fig.
1
System
w/
single
block
Fig.2
System
w/
multiple
blocks
★
The
MC-60/4
is
rated
to
operate
at
temperatures
between
0°C
~
+40°C
(32°F
~
104°F).
★
Clean
the
MC-60/4
equipment
with
a
soft
cloth
dampened
with
neutral
household
cleanser.
Never
use
any
abrasive
cleaner
or
cloth.
SPECIFICATIONS
*
Power
source:
*
Consumption:
*
Calling:
*
Communication:
*
Talk
channel:
*
Station
capacity:
*
Wiring:
*
Dimensions:
*
Weight:
DC24V.
Use
PS-24N
power
supply
Max.
70mA
(in
paging
mode)
By
paging
Enters
each
channel
after
pressing
a
channel
selector
button.
4
channels
Max.
60
stations
(in
6
blocks
each
with
10
MC-60/4
stations
max.
per
block)
7
conductors
in
loop
(do
not
use
twisted
paired
cable)
Use
specified
type
No.
852207
(USA
only),
420172
or
line
capacitance
rating
less
than
25pF/feet.
MC-60/4
A:
9-1/4”H
x
3-1/2”Wx
3-1/2”D;
235H
x
90W
x
90D(mm)
MC-60/4B:
4”Hx8-7/8”Wx7-1/2”D;
102H
X225WX
190D(mm)
MC-60/4A:
1.06
lbs.
(480g)(approx.).
MC-60/4B:
2.65
lbs.
(1.2kg)(approx.).
*
Wiring
distance:
•
Max.
distance
from
MC-A/A
to
farthest
MC-60/4
of
a
block
(dl
in
above
Fig.
1)
24AWG
22AWG
18AWG
1,000’
1,700’
4,000’
0.5mm^
0.65mm
<f>
1.0mm
(p
300m
500m
1,200m
Also
applies
to
farthest
MC-60/4’s
of
different
blocks
(d2
in
above
Fig.2)
★
Total
wiring
distance
must
not
exceed
5,000’(1,500m)
per
system,
regardless
of
wire
size.
Total
wiring
distance
is
the
total
length
of
all
wiring
blocks
added
together.
•
From
MC-A/A
to
power
supply
PS-24N
18AWG
0.5mm
^
32’
10m
t
WARRANTY
J
Aiphone
warrants
its
products
to
be
free
from
defects
of
material
and
workmanship
under
normal
use
and
service
for
a
period
of
one
year
after
delivery
to
the
ultimate
user
and
will
repair
free
of
charge
or
replace
at
no
charge,
should
it
become
defective
upon
which
examination
shall
disclose
to
be
defective
and
under
warranty.
Aiphone
reserves
unto
itself
J
the
sole
right
to
make
the
final
decision
whether
there
is
a
defect
in
materials
and/or
workmanship;
and
whether
or
not
the
X
product
is
within
the
warranty.
*
This
warranty
shall
not
apply
to
any
Aiphone
product
which
has
been
subject
to
misuse,
neglect,
accident,
or
to
use
in
J
violation
of
instructions
furnished,
nor
extended
to
units
which
have
been
repaired
or
altered
outside
of
the
factory.
This
<+
►
warranty
does
not
cover
batteries
or
damage
caused
by
batteries
used
in
connection
with
the
product.
J
This
warranty
covers
bench
repairs
only,
and
any
repairs
must
be
made
at
the
shop
or
place
designated
in
writing
by
Aiphone.
Aiphone
will
not
be
responsible
for
any
costs
incurred
involving
on
site
service
calls.
Aiphone
Co.,
Ltd.,
Nagoya,
Japan
Aiphone
Corporation,
Bellevue,
WA,
USA
MC-60/4-l(E)
0496D
©
C
OMMUNICATION
SYSTEMS
AIPHONE
HOME,
BUSINESS,
INDUSTRY.
Printed
in
Japan
(E)
-6
—
This manual suits for next models
1
Table of contents
Other Aiphone Conference System manuals