NDR Lamp Memory System with Access/Camera Control
- 41 -
ARCHITECTS/ENGINEERS’ SPECIFICATIONS:
The intercom system shall be of an open voice, selective
calling type, available in 10, 20, 30 or 40 station sizes, with
20 and 40 station add-on selectors for expansion.
Master station shall have individual selector buttons with
associated LEDs for call-in indication, and a directory for
station labeling. A call from a sub shall light the LED and
activate the call tone until the call is answered. The call
shall be answered by pressing the station’s selector button,
then TALK button to transmit, and release to listen (or via
handset with “A” model). Hands free reply from sub. The
system shall include All Call, allowing the master to make
general announcements to all remote stations. There shall
be no talkback from an All Call.
SPECIAL ORDER PRODUCTS:
Master Stations
NDR-10 10-call Master w/selective outputs
NDR-10A 10-call Mstr. w/hndst. & sel. outputs
NDR-20 20-call Master w/selective outputs
NDR-20A 20-call Mstr. w/hndst. & sel. outputs
NDR-30 30-call Master w/selective outputs
NDR-30A 30-call Mstr. w/hndst. & sel. outputs
NDR-40 40-call Master w/selective outputs
NDR-40A 40-call Mstr. w/hndst. & sel. outputs
Add-on Selectors
ND-20AS
20-call Add-on Selector w/sel. outputs
ND-40AS
40-call Add-on Selector w/sel. outputs
Sub Stations
NE-JA Flush mnt. weather resistant door stn.
NE-DA
Surface mnt. weather resistant door stn.
Accessories
BA-1 Paging adaptor
STANDARD PRODUCTS:
Sub Stations
Same as NEM Series
Accessories
RY-PA Relay for each selective output
(One required for each function controlled
from NDR master. If both momentary and
maintained closures are required on the
same channel, an isolation diode is
required for each set of relays.
Diagram shown in NDR instructions)
Amplifiers and speakers available for paging zones.
All other accessories: same as the NEM series.
Master station shall be equipped with power ON/OFF switch,
transmit and receive volume controls, ALL CALL, TALK and
door release buttons. Station selectors shall be in rows of
five, with an OFF button for each row. ALL CALL button shall
initiate a call to all connected stations. A “POWER” LED shall
indicate incoming power to the master station.
Compatible remote stations shall include surface or flush
mount styles, with or without privacy, outdoor stations, and
vandal proof stations (surface or flush mounted, weather
resistant).
System shall be manufactured by Aiphone.
NDR (2)
=RY-PA relays
NOTE:
Powersources for intercom,
doorstrikes, and cameras
notshown.
SYSTEM LAYOUT EXAMPLE:
32
Coax
3 4 5
2 3 4
NA-NENE-DANE-JANE-JA
NDR-20A
Video Switcher
(NotsuppliedbyAiphone)
NA-NE
Coax
(Loopwiringmethodshown.
Otherwise,homerun2conductorsfromeachremote.)