manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Aiphone
  6. •
  7. Intercom System
  8. •
  9. Aiphone NE-NVP-RA User manual

Aiphone NE-NVP-RA User manual

This manual suits for next models

1

Other Aiphone Intercom System manuals

Aiphone MY-1CD User manual

Aiphone

Aiphone MY-1CD User manual

Aiphone IC-D1 User manual

Aiphone

Aiphone IC-D1 User manual

Aiphone AP-1M User manual

Aiphone

Aiphone AP-1M User manual

Aiphone DA-1MD User manual

Aiphone

Aiphone DA-1MD User manual

Aiphone TA-12F User manual

Aiphone

Aiphone TA-12F User manual

Aiphone INTERCOM AN-8000 User manual

Aiphone

Aiphone INTERCOM AN-8000 User manual

Aiphone JK-1MED User manual

Aiphone

Aiphone JK-1MED User manual

Aiphone MID-POWER MP-1S User manual

Aiphone

Aiphone MID-POWER MP-1S User manual

Aiphone GT-1C7W User manual

Aiphone

Aiphone GT-1C7W User manual

Aiphone MC-D User manual

Aiphone

Aiphone MC-D User manual

Aiphone GF-NS User manual

Aiphone

Aiphone GF-NS User manual

Aiphone IE-1AD User manual

Aiphone

Aiphone IE-1AD User manual

Aiphone AN-8031MS User manual

Aiphone

Aiphone AN-8031MS User manual

Aiphone IX-SS-2G User manual

Aiphone

Aiphone IX-SS-2G User manual

Aiphone PB-2 User manual

Aiphone

Aiphone PB-2 User manual

Aiphone LEM-1DL User manual

Aiphone

Aiphone LEM-1DL User manual

Aiphone MYW-P3L User manual

Aiphone

Aiphone MYW-P3L User manual

Aiphone DOOR RELEASE RELAY MODULE RY-24L User manual

Aiphone

Aiphone DOOR RELEASE RELAY MODULE RY-24L User manual

Aiphone MK-1SD/B User manual

Aiphone

Aiphone MK-1SD/B User manual

Aiphone TC-MC User manual

Aiphone

Aiphone TC-MC User manual

Aiphone KB-DAR User manual

Aiphone

Aiphone KB-DAR User manual

Aiphone LAF-10BS User manual

Aiphone

Aiphone LAF-10BS User manual

Aiphone WP100A User manual

Aiphone

Aiphone WP100A User manual

Aiphone IS-IPDVF-HID User manual

Aiphone

Aiphone IS-IPDVF-HID User manual

Popular Intercom System manuals by other brands

Videx VRDK1 (25H) Technical manual

Videx

Videx VRDK1 (25H) Technical manual

Auta COMPACT VISUALTECH manual

Auta

Auta COMPACT VISUALTECH manual

Comelit 4893M Technical manual

Comelit

Comelit 4893M Technical manual

MGL Avionics V16 manual

MGL Avionics

MGL Avionics V16 manual

SSS Siedle BVI 750-0 Installation & programming

SSS Siedle

SSS Siedle BVI 750-0 Installation & programming

urmet domus AIKO 1716/1 quick start guide

urmet domus

urmet domus AIKO 1716/1 quick start guide

urmet domus IPerVoice 1039 Installation

urmet domus

urmet domus IPerVoice 1039 Installation

Alpha Communications STR QwikBus TT33-2 Installation, programming, and  user's manual

Alpha Communications

Alpha Communications STR QwikBus TT33-2 Installation, programming, and user's manual

Monacor ICM-20H instruction manual

Monacor

Monacor ICM-20H instruction manual

Logenex A202CR Installation & programming

Logenex

Logenex A202CR Installation & programming

Quantum QR5 Installation and programming manual

Quantum

Quantum QR5 Installation and programming manual

EVGA XR1 quick guide

EVGA

EVGA XR1 quick guide

CyberData 011211 series Installation quick reference

CyberData

CyberData 011211 series Installation quick reference

Vidos duo M1021 user manual

Vidos

Vidos duo M1021 user manual

Savant DOR-SMS-00 Deployment guide

Savant

Savant DOR-SMS-00 Deployment guide

SSS Siedle BTSV 850-03 operating instructions

SSS Siedle

SSS Siedle BTSV 850-03 operating instructions

Dahua VTO Series quick start guide

Dahua

Dahua VTO Series quick start guide

Elvox 5651 Wiring instructions

Elvox

Elvox 5651 Wiring instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

- INSTRUCTIONS -
The NE-NVP-RA sub station is vandal proof, and can be used with the NEM or the NEM-RS systems. Designed for
Rescue Assistance applications and ADA compliance, this unit features Emergency and Braille signage, a large red
call button, and "Call Placed" and "Help Coming" LED indicators. Remote indicators can be added for better
visibility of a station's status. A standard NEM master requires a manual reset button at each location, or the master
station can be equipped with a reset button (NEM-nRS version). The NE-NVP-RA is designed to be surfaced
mounted, requiring the SBX-NVP surface mount box. Tamper proof screws are provided, along with a wrench for
installation.
WIRING DIAGRAM FOR SYSTEM WITH CALL RESET AT THE MASTER
NEM-nRS Master Station Required
NE-NVP-RA
Vandal Proof Sub Station for NEM System
Requires surface mount box
SBX-NVP
Blue
Blue
NAR-2A*
Special
Order
Products
ADA
Americans with
Disabilities Act
NE-NVP-RA
Use a designated
wire from each no.
terminal to sub
station's RED wire.
Red
Blue
Purple
Black
Yellow
Orange
Green
jumper
(Do not cut)
NE-NVP-RA
Red
Blue
Purple
Black
Yellow
Orange
Green
jumper
(Do not cut)
Use a designated
wire from each no.
terminal to sub
station's RED wire.
WIRING DIAGRAM FOR SYSTEM WITH OVERHEAD LAMPS AND A RESET BUTTON.
Standard NEM master used.
NE-NVP-RA
Red
Blue
Purple
Black
Yellow
Orange
Green
jumper
(Cut)
Blue
Blue
Blue
Blue
* Reset Button:
(Any normally closed button or
keyswitch. Not required when
using the NEM-RS master.)
NBY-4A
"Help Coming" light
NBY-4A
"Call Activation" light
+
-
NEM-n Master
PS-2410A
or PS-24E
1
2
3
~
20
E
S
H
+
-
+
-
NEM-nRS Master
PS-2410A
or PS-24E
1
2
3
~
20
E
S
H
+
-
Pg. 1
SPECIFICATIONS:
Power Source: Supplied by master station
Speaker: 20 ohms, 3" diameter, water proof and puncture resistant, 2.5 oz. ceramic magnet
Call Button: Single pole, single throw (SPST), normally open (N/O)
Faceplate: 11 gauge carbon steel with powder-coated white baked epoxy finish
Call Annunciation: Pressing call button at sub latches call at NEM master until answered
Communication: Hands free at sub. Master is push-to-talk or VOX handset
Mounting Hardware: Tamper proof screws
Terminations: Color-coded prewired pigtails
Wiring: With remote reset switch: 4-conductor homerun from each sub, or 3 common wires plus 1
individual wire per sub station, looped.
With NEM-RS master: 4-conductor homerun from each sub, or 3 common wires plus 1
individual wire per sub station, looped.
Shielded wire is recommended.
Use Aiphone #822206 for homerun wiring, #822210 for up to 6 stations
on each run, or #822220 for up to 17 stations on each run.
Wiring Distance: 420' with 22AWG; 1,000' with 18AWG.
Dimensions (H x W x D):NE-NVP-RA alone: 7-1/2" x 5-1/2" x 2". With SBX-NVP: 8-5/8" x 6-5/8" x 2-1/4"
Pg. 2
NE-NVP-RA Instr.
0698bkjd
OPERATION:
1. When a sub station places a call, the "Call Placed" (Red) and "Help Coming" (Green) LEDs on the
sub station light.
2. When a call is answered, the red "Call Placed" LED on the sub turns off.
The green "Help Coming" LED stays on.
3. When the master station's reset button is pressed or if a remote reset switch is activated, all of the
call indicator lights will go off.
4. If overhead lamps are installed in the system, they will light in the same way that the LED's light,
as descirbed above.
BRAILLE SIGNAGE:
The NE-NVP-RA is equipped with Braille signage for the visually impaired.
ON TOP OF UNIT:
EMERGENCY
"EMERGENCY - CALL FOR HELP"
ON BOTTOM OF UNIT:
"PUSH BUTTON. TONE INDICATES CALL PLACED"
Plating material is .012" aluminum with 5 letter spacing.
Aiphone Communication Systems
1700 130th Ave. N.E.
Bellevue, WA 98005
(425) 455-0510
FAX (425) 455-0071
TOLL FREE TECHNICAL SUPPORT:
(800) 692-0200
TOLL FREE FAX LINE:
(800) 832-3765
TECHNICAL SUPPORT E-MAIL: