manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Aiphone
  6. •
  7. Intercom System
  8. •
  9. Aiphone NE-SS-1G User manual

Aiphone NE-SS-1G User manual

Other Aiphone Intercom System manuals

Aiphone AN-8000EX User manual

Aiphone

Aiphone AN-8000EX User manual

Aiphone LEM-1 User manual

Aiphone

Aiphone LEM-1 User manual

Aiphone GT SYSTEM User manual

Aiphone

Aiphone GT SYSTEM User manual

Aiphone AX SERIES User manual

Aiphone

Aiphone AX SERIES User manual

Aiphone IX-MV User manual

Aiphone

Aiphone IX-MV User manual

Aiphone MYW-P1L User manual

Aiphone

Aiphone MYW-P1L User manual

Aiphone GT-1C7W User manual

Aiphone

Aiphone GT-1C7W User manual

Aiphone KB-3HRD User manual

Aiphone

Aiphone KB-3HRD User manual

Aiphone IE-2AD(U) User manual

Aiphone

Aiphone IE-2AD(U) User manual

Aiphone IE-DL1 User manual

Aiphone

Aiphone IE-DL1 User manual

Aiphone LEF Series User manual

Aiphone

Aiphone LEF Series User manual

Aiphone GH-1AD User manual

Aiphone

Aiphone GH-1AD User manual

Aiphone LC-10S User manual

Aiphone

Aiphone LC-10S User manual

Aiphone NE-JA User manual

Aiphone

Aiphone NE-JA User manual

Aiphone LE-DL User manual

Aiphone

Aiphone LE-DL User manual

Aiphone IBG-1GD User manual

Aiphone

Aiphone IBG-1GD User manual

Aiphone RCX-48CEU/B User manual

Aiphone

Aiphone RCX-48CEU/B User manual

Aiphone VB-10DM User manual

Aiphone

Aiphone VB-10DM User manual

Aiphone IXG Series User manual

Aiphone

Aiphone IXG Series User manual

Aiphone MY-1HD User manual

Aiphone

Aiphone MY-1HD User manual

Aiphone JM-DVF-L User manual

Aiphone

Aiphone JM-DVF-L User manual

Aiphone JOS-1A User manual

Aiphone

Aiphone JOS-1A User manual

Aiphone NEM-10 User manual

Aiphone

Aiphone NEM-10 User manual

Aiphone LEF-5 User manual

Aiphone

Aiphone LEF-5 User manual

Popular Intercom System manuals by other brands

Videx VRDK1 (25H) Technical manual

Videx

Videx VRDK1 (25H) Technical manual

Auta COMPACT VISUALTECH manual

Auta

Auta COMPACT VISUALTECH manual

Comelit 4893M Technical manual

Comelit

Comelit 4893M Technical manual

MGL Avionics V16 manual

MGL Avionics

MGL Avionics V16 manual

SSS Siedle BVI 750-0 Installation & programming

SSS Siedle

SSS Siedle BVI 750-0 Installation & programming

urmet domus AIKO 1716/1 quick start guide

urmet domus

urmet domus AIKO 1716/1 quick start guide

urmet domus IPerVoice 1039 Installation

urmet domus

urmet domus IPerVoice 1039 Installation

Alpha Communications STR QwikBus TT33-2 Installation, programming, and  user's manual

Alpha Communications

Alpha Communications STR QwikBus TT33-2 Installation, programming, and user's manual

Monacor ICM-20H instruction manual

Monacor

Monacor ICM-20H instruction manual

Logenex A202CR Installation & programming

Logenex

Logenex A202CR Installation & programming

Quantum QR5 Installation and programming manual

Quantum

Quantum QR5 Installation and programming manual

EVGA XR1 quick guide

EVGA

EVGA XR1 quick guide

CyberData 011211 series Installation quick reference

CyberData

CyberData 011211 series Installation quick reference

Vidos duo M1021 user manual

Vidos

Vidos duo M1021 user manual

Savant DOR-SMS-00 Deployment guide

Savant

Savant DOR-SMS-00 Deployment guide

SSS Siedle BTSV 850-03 operating instructions

SSS Siedle

SSS Siedle BTSV 850-03 operating instructions

Dahua VTO Series quick start guide

Dahua

Dahua VTO Series quick start guide

Elvox 5651 Wiring instructions

Elvox

Elvox 5651 Wiring instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

+
-
- INSTRUCTIONS -
The NE-SS-1G is a 1-gang vandal proof and weather resistant sub stations designed for use with the NEM, NDR and
NDRM systems. This unit is constructed of 12 gauge stainless steel and is equipped with an option for an external output
contact closure when the sub station places a call (relay required). The unit either flush mounts into a 1-gang box, or
surface mounts with the SBX-1G. Each unit includes tamper proof screws and a tool for installation.
WIRING DIAGRAM:
Vandal and Weather Resistant 1-Gang Sub Station
1
2
3
~
20
E
+
-
H
Red
Blk
Blu
Red
Blk
Blu
Wht
NEM Master NE-SS-1G NE-SS-1G
(w/dry closure output)
PS-2420UL
RY-PA
Blk Blk
Yel
Dry closure
output for
duration of call-in
Red
Blk
Blu
NE-SS-1G
(w/corridor lamp)
Blu
Blu
NBY-4A
INSTALLATION:
1. For flush mounting, install sub station in standard 1-gang electrical box with min. 2-1/2" depth.
2. For surface mounting, install sub station in the SBX-1G surface mount enclosure.
3. IMPORTANT! This unit is designed for use in normal weather conditions, and is made to allow for drainage and
evaporation of moisture that naturally gets into it. Do not apply caulking or silicone sealant around the unit
when installing, and do not use weather stripping around the perimeter of the box when mounting. If
sealing the unit is required, the bottom must remain unsealed. Sealing the unit will prevent or inhibit moisture from
dissipating from inside the unit, which may cause corrosion or deterioration to the internal components over time.
Warranty does not cover damage caused by sealing the unit.
Page 1
WIRE DESIGNATIONS:
Red: + side of speaker. Connect to station number on master station.
Blue: Trigger for corridor lamp. 7V DC when call-in signal is activated.
Black: - side of speaker (common). Connect to E on master station.
White: Negative trigger wire for extra relay contact closure at sub during call-in.
Small wht & blk: Speaker connection to PCB
Small brn (x2): Call button connection to PCB
Back View 2-⅞”3-¼”
1- ⁄”
1516
NE-SS-1G
SPEAKER
CALL BUTTON WITH
CALL ASSURANCE LED
Aiphone Communication Systems
1700 130th Ave. N.E.
Bellevue, WA 98005
(425) 455-0510
FAX (425) 455-0071
NE-SS-1G Instr.
1011JD
SPECIFICATIONS:
Power Source: Supplied by master station
Speaker: 20 ohms, 1.92" square, water proof and puncture resistant, 0.44 oz. magnet
Call Button: SPST call button, momentary activation limited stop button.
Call Annunciation: Pressing the call button at sub activates and latches call at NEM master. The master
station's LED will be lit and a ringing tone will be heard until the call is answered.
Communication: Hands free at sub. Master is push-to-talk or VOX with handset.
Faceplate: 12 gauge stainless steel
Mounting: Flush mount into a 1-gang box. Surface mount into SBX-1G, sold separately. Tamper proof screws
included (6x32 for use with flush gang box) with T-10 TORX bit.
Use hardware included with SBX-1G when installing sub into that unit.
Terminations: Color-coded prewired pigtails
Operating Temperature: Speaker rating: -67°F to 185°F (-55°C to 85°C)
Switch rating: -40°F to 257°F (-40°C to 125°C)
Wiring: 2 conductors homerun; or 1 common plus 1 individual per sub, looped through each sub.
Shielded cable is recommended.
Use Aiphone #822202 or #821802 for homerun wiring, #822206 for up to 5 stations
on each run, or #822210 for up to 9 stations on each run.
Wiring Distance: 420' with 22AWG; 1,000' with 18AWG
Dimensions (HxWxD): NE-SS-1G alone: 4-1/2" x 2-3/4" x 1-5/8"
With SBX-1G: 4-9/16" x 2-15/16" x 2-7/8" (Top) 2-1/8" (Bottom)
Toll Free Technical Support:
1-800-692-0200
E-mail [email protected]
+
-
WIRING DIAGRAM:
1
E
H
2
E
H
3
E
H
Red
Blk
Wht
Blu
NDRM Master
CP-544A board
NE-SS-1G
NE-SS-1G
(w/dry closure output)
PS-2420UL
RY-PA
Blk Blk
Yel
Dry closure
output for
duration of
call-in
A+
A-
B+
B-
H
Q
E
S
B
Y
A1
V1
A2
V2
CP-544A board
Red
Blk
Wht
Blu
OPERATION:
1. To place a call from the remote station: Press the call
button once, then release and wait for a response
from the master station. The call tone and LED
indicator at the master will remain activated until the
call is answered. The call indicator LED on the door
station will be lit to indicate that a call has been
placed.
2. To answer the call at the master station: Press the
channel selector button with the lit LED, which
indicates which remote has called in. Press TALK
button to talk, release to listen.
3. Speak hands free at the remote station.
4. To conclude the call, press the OFF button.
5. To initiate a call from the master station to the remote,
simply press the channel selector button, then
TALK to speak to the person at the remote.
6. Press OFF to conclude the call.