Air Air Sniper Tower Owner's manual

Air Sniper™
Owner operator manual

Introduction
Set-up Instructions
Features/How To
• Fan Speed
• Sleep Mode
• Motion Sensor
• Bulb Life
• Filter Warning
Maintenance
• Air Sniper tower
• Air Sniper Pro/Elite
Troubleshooting
Replacement Parts
Warranty
Contact Info
Air Sniper™
Tower | Pro | Elite
1
2
3-5
5-8
9
10
11
12
3
3
3
4
4
5-6
7-8

Air Sniper Tower Air Sniper PRO Air Sniper ELITE
Congratulations on your purchase of Air Sniper air sterilizer, Alpine Innovative Research Inc.‘s most advanced
and cost-effective air sterilizer, combining filtration, germicidal ultraviolet irradiation and photo-catalysis to
control airborne pathogens/allergens, particulates, microbes, and odours. The high quality of this unit and its
components will ensure many years of trouble-free, low-maintenance operation.
1
Suggested Coverage 400 – 600 sqft
Adjustable Fan Speed (50 – 90 cfm)
72 Watts UVC
Suggested Coverage 800 – 1200 sqft
Adjustable Fan Speed (70 – 130 cfm)
108 Watts UVC
Suggested Coverage 1500 – 2300 sqft
Adjustable Fan Speed (130 – 250 cfm)
216 Watts UVC
Air Sniper™

Set-up instructions & features
1
Remove Air Sniper™ from crate or carton and remove any exterior wrappings.
2
Plug in power cord (115V/60Hz or 230V/50Hz receptacle).
3
Turn Air Sniper Power ON
4
When you first turn on your Air Sniper it will begin at maximum fan speed to cycle the air out of the unit.
5
Bulb light will glow red if bulbs are broken or displaced during shipping.
6
Set fan speed (Up/Down arrows). There are four speeds.
7
Listen to operating unit and “air rush” sound. If there are any "unusual"
noises, immediately turn off the power and notify your Dealer or AIR, Alpine
Innovative Research Inc as shipping damage may have occurred.
8
Check that there are no red fault (fail) lights glowing. These lights, if
"red", are indicators of failures in the major components of the system. If all lights
are green and blue the unit is already cleaning your air. The unit effectively cleans the air at all fan speeds. However, higher fan speeds increase
the flow through the unit thereby increasing the volume of air treated in a given time. Increased fan speeds are accompanied by increased "air
rush" noise, so owners may adjust speeds to noise level tolerance.
WARNING: Do not attempt to operate the UV-C lamps outside the unit. UV-C radiation is extremely harmful to
unprotected (uncovered)
eyes and skin.
WARNING: Do not attempt to operate the UV-C lamps outside the unit. UV-C radiation is extremely harmful to
eyes and skin.
2
DO NOT REMOVE ANY PANEL OR PERFORM ANY SERVICE UNLESS THE UNIT HAS BEEN SWITCHED OFF AND UNPLUGGED.
DO NOT OPERATE A UNIT THAT HAS BEEN DAMAGED OR IS MISSING ANY COMPONENTS OR SAFETY DEVICES.
NEVER POWER UP THE UNIT WITHOUT CHASSIS PANELS OR WASHABLE FILTER(S) IN PLACE.
NEVER POWER UP UV LAMPS OUTSIDE OF THE UNIT.

The fan(s) always go to full
speed for 2 seconds on
power up then to the users
setting (if its last setting
was lower than full speed).
Use the up/down buttons
to select 1 of 4 fan speeds.
The Air Sniper remembers
both the on/off state and
fan speed and will resume
the previous state after a
power cycle.
Setting Fan Speed
2”
3
Sleep Mode
The LEDs will dim and the
fan will go to its lowest
speed.
To exit sleep mode
press any button.
The unit will return to the
last speed setting set by
the user.
Sleep mode is activated
by holding the Power
button for 3 seconds
while the unit is running.
3”
Motion Sensor
Press both the Up and
Down arrows together
until the blue fan lights
blink. Press the Up
Down arrows to set
desired fan level.
Press both up and down
again to exit or wait 30
seconds for it to timeout.
A user can override
the fan speed anytime
by turning the fan
up (or down). This
manual override lasts
90 minutes. After 90
minutes the motion
sensor is active again.
30”
90’
Features/How To

Bulb Life Warning
(Refer to the maintenance section to find
directions on how to replace your bulbs)
Once you receive your
replacement bulbs you
will be provided a reset
sequence from AIR in order
to reset the internal timers
for another 13,128 hours
of air sterilization
After 18 months or Approx.
547 days of power-on time
the unit will turn off and
indicates the bulbs need
replacing.
>
4
Removable Filter Warning
(Refer to the maintenance section to find
directions on how to clean your filter)
If the filter is 50% plugged
the LED will flash RED.
If the filter is 75% plugged
the filter LED is on and the
unit shuts down.
50%
Filter
Filter
75%
The bulb LED will blink on/
off for 1 minute every 30
minutes once it hits 15
months or after 456 days
power-on time.
>30’
This is the case on full
speed. As you go to a lower
speed more of the filter
may need to be plugged to
get the LED to light.

Filter Cleaning - Air Sniper Tower
The filter light will flash red if it is 50% saturated or greater. When it is 75% saturated or greater The filter light will glow solid red and the unit will turn off
until clean & dry.
To access the filters, remove the 4 screws on
top using a Phillips screwdriver.
1
Pull out each of the 4 filters and run each filter
under warm water making sure to rinse them in
reverse of the air flow (refer to the arrow) so that
the water can push the particles out.
2
Place all 4 filters back in the unit with the green
mesh facing out and in accordance to the Air
Flow Arrows facing inward. Place lid on unit and
tighten screws. Do not over-tighten screws.
4
3As the water runs through the filter, wipe the mesh side
with a wet cloth. DO NOT SUBMERGE THE FILTERS.
Allow filters dry for 1 hour.
WARNING: Unplug the unit and ensure that there is no power. UV-C radiation is extremely harmful to unprotected eyes & skin.
5

UV-C Bulb Replacement - Air Sniper Tower
The bulb light will flash once every 30 minutes once the bulbs have reached 10,944 hours of use (465 days 24/7) and the bulb light will turn red and unit
will shut off completely once it has reached 13,128 hours (547 days 24/7). You can order new bulbs on AirSniper.ca.
To access the bulbs, remove the 4 screws on
top using a Phillips screwdriver.
1
Disconnect the bulb base from the white
molex that contains the power wires.
2
Remove the 2 wing-nuts on the bulb housing and
carefully slide it up and over the bulbs.
5
Flip the bulb base back over and Re-insert it into
the unit. Hand tighten the 4 wing-nuts to secure it.
7
Replace the cover and hand tighten the 4 screws.
Do not over tighten screws. Plug in the unit and
turn the power on. Enter the unique reset code
provided with your replacement bulbs
9
Remove ONLY the 4 wing nuts to detach the bulb
base from the top panel of the unit.
3
Gently lift up the bulb base to expose the bulb
housing. Flip the housing upright and place
on an even surface.
4
Remove the bulbs from there sockets and
recycle them. Clip in new replacement bulbs
and carefully replace bulb housing and tighten
the 2 wing-nuts.
6
Re-connect the white molex power clips to the bulb base
securely.
8
WARNING: Unplug the unit and ensure that there is no power. UV-C radiation is extremely harmful to unprotected eyes & skin.
6

Filter Cleaning - Air Sniper Pro + Elite
The filter light will flash red if it is 50% saturated or greater. When it is 75% saturated or greater the filter light will glow solid red and the unit will turn off
until clean & dry.
Remove the filter by pulling up gently on
the filters tab. The internal titanium coated
elements never need cleaning.
1
2Run the filter under warm water making sure to rinse
them in reverse of the air flow (refer to the arrow) so
that the water can push the particles out. As the water
runs through the filter, wipe the bottom with a wet
cloth. DO NOT SUBMERGE THE FILTER.
3Once you have completed rinsing the filters
Let them dry completely for 1 hour. Once
they are dry, place the filters back in the
unit pay attention to the airflow direction
indicator on the filter.
Plug in the Air Sniper and turn the power on.
Ensure that the filter light is green and the unit
appears to be operating correctly. If the filter
light is red, it may be because the filter is still
wet or it is not firmly placed in the unit. Please
wait an additional 30 minutes and try to turn it
on again.
4
7
WARNING: Unplug the unit and ensure that there is no power. UV-C radiation is extremely harmful to unprotected eyes & skin.

UV-C Bulb Replacement - Air Sniper Pro + Elite
The bulb light will flash once every 30 minutes once the bulbs have reached 10,944 hours of use (546 days 24/7) and the bulb light will turn red and unit
will shut off completely once it has reached 13,128 hours (547 days 24/7). You can order new bulbs on AirSniper.ca.
To access the bulbs, remove the 9
screws on side and top of the UVGI
Panel using a Phillips screwdriver.
1
2Remove the UVGI enclosure panel and set aside.
6Plug in the Air Sniper and turn the power on.
Enter the unique button reset code that was
sent with the bulbs.
2b(OPTIONAL) The middle 2 internal UVGI
elements can be removed to assist those with
larger hands in the removal of bulbs. WARNING:
DO NOT WASH THE UVGI ELEMENTS
3Pull out the bulb restraint clip that
secures the bulbs. Grip the tab at the
end and pull straight out.
Remove the burnt out or damaged bulb(s) and
recycle. Place the new bulb(s) in the socket
securely and replace the restraint clip.
Replace internal UVGI filters if they were
removed in step 2b.
4
5Replace the UVGI enclosure panel
and hand tighten the 9 screws so the
panel is securely fastened. WARNING:
Ensure there is a tight seal before turning
the power on to the unit. Exposure to UV
light can damage unprotected skin and eyes.
8
WARNING: Unplug the unit and ensure that there is no power. UV-C radiation is extremely harmful to unprotected eyes & skin.

Air Sniper™ unit will not start.
Ensure Air Sniper™ unit is connected to
AC Power (115V 60Hz or 230V 50Hz).
If power connections OK, contact Dealer or Alpine
Innovative Research.
Turn off and unplug Air Sniper™ unit. Remove
access cover and check the condition of each UV
bulb filament. Any defective bulbs (broken
envelope or filament) must be replaced per
UV-C Bulb Replacement procedure (above). If
“Light Fail” does not reset after this procedure
there may be a failure of the ballast.
Contact Dealer or Alpine Innovative Research for
return procedure and maintenance request.
Fan on, Light Fail (solid red light).
Check condition of washable pre-filter(s). If
the filters are saturated proceed to routine
maintenance section for washing instructions.
If washable pre-filter(s) appear to be in good /
serviceable condition, contact Alpine Innovative
Research.
No airflow (Filter red light solid on);
unit shut down.
Do not attempt to disassemble or repair the Air
Sniper
™
fan yourself.
If power connections OK, contact Dealer or Alpine
Innovative Research.
Fan not on (Fan solid red light).
Check condition of washable pre-filter(s). If
the filters are saturated proceed to routine
maintenance section for washing instructions.
If washable pre-filter(s) appear to be in good /
serviceable condition, contact Alpine Innovative
Research.
Restricted airflow (Filter red light
blinking).
9
WARNING: Do not attempt to operate the UV-C lamps outside the unit. UV-C radiation is extremely
harmful to unprotected (uncovered) eyes and skin.
Trouble Shooting

Dimensions
Power Requirements
Weight, system incl. filters
Fan Speed
Housing Material
Suggested Coverage
UVGI Chambers
Washable Prefilters
Sleep Mode
Motion Sensor
iPhone/Android App
37.5cm(W) 59.7cm(H) 37.5cm(D)
110-240V, 60/50 HZ
37lb (17.78kg)
50 – 90 cfm
Brushed Stainless steel
400 – 600 ft2
1
Yes
Yes
Yes
Yes
56.5cm(W) 37.5cm(H) 19.1cm(D)
110-240V, 60/50 HZ
40lbs. (18.14kg)
70 – 130 cfm
Brushed Stainless steel
800 – 1200 ft2
3
Yes
Yes
Yes
Yes
64.8cm(W) 52.7cm(H) 24.1cm(D)
110-240V, 50/60 HZ
65lbs (29.48 kg)
130 – 250 cfm
Brushed Stainless steel
1500 – 2300 ft2
3
Yes
Yes
Yes
Yes
Air Sniper Tower Air Sniper Pro Air Sniper Elite
Parts List
Part Description Amount Unit Part
18 Watt UV-C Bulb 6 010NS18
Pre-Filter 1 040P12725
Photocatalytic Element 4 6SP-0010
Parts List
Part Description Amount Unit Part
36 Watt UV-C Bulb 2 020NS36
Pre-Filter 4 030T18750
Photocatalytic Element 4 060T18750
Parts List
Part Description Amount Unit Part
36 Watt UV-C Bulb 6 020NS36
Pre-Filter 1 050E18950
Photocatalytic Element 4 080E18850
Air Sniper™
Family of Air Purifiers
To order your replacement
parts visit AirSniper.ca
Replacement Parts
10

Limited Warranty
Three Year Warranty
Alpine Innovative Research Inc. (AIR) warrants the Air Sniper™ to be free from
defects in the workmanship or materials under normal use and service (the
“Warranty”) for a period of three (3) years (the “Warranty Period”) from the
date of purchase through an AIR-authorized dealer/distributor. During the
Warranty Period, should a Air Sniper™ be determined to be defective, AIR shall
repair or replace the defective Air Sniper™ unit(s) (at AIR or dealer’s option)
within a reasonable period of time.
Thirty Day Guarantee
In the event you are not completely satisfied with your Air Sniper product
within 30 days from the proof of purchase date. Return it to Air Alpine
Innovative Research for a full refund.
Remedy Procedures
If the Air Sniper™ proves defective within the Warranty Period, the purchaser
may choose one of the following remedies, after contacting AIR for a Return
Authorization Number:
1. Return the defective Air Sniper™ unit to the dealer/distributor from
whom it was purchased together with a copy of the bill of sale, or dated
proof of purchase thereof and the Return Authorization Number; or
2. Ship the defective Air Sniper™ unit directly to Air Alpine Innovative
Research Customer Warranty Department along with the Return
Authorization Number.
Limitations
1. This Warranty is the only representation regarding the Air Sniper™, by
Alpine Innovative Research Inc. of merchantability and fitness for use
and shall extend to three (3) years from the date of purchase. The
warranty excludes replaceable UVC bulbs and PCO (photocatalytic
Elements.)
2. If it is determined by either Alpine Innovative Research Inc or an
authorized dealer/distributor that the defect is the result of damage
caused by the purchaser, the Warranty is null and void.
Contact Us
Any questions or concerns pertaining to this Warranty may be directed to AIR
by E-mail, telephone, or facsimile:
AIR, Alpine Innovative Research.
Customer Warranty Department
3855 - 64th Avenue SE
Calgary, Alberta, Canada T2C 2V5
Toll Free 1 (888) 338-9549
Fax 1 (403) 279-7738
Email info@airsniper.ca
11
2. Ship the defective Air Sniper™ unit directly to Air Alpine Innovative
Research Customer Warranty Department along with the Return
Authorization Number.
Toll Free 1 (888) 338-9549
Fax 1 (403) 279-7738
Email info@airsniper.ca
11

airsniper.ca
This manual suits for next models
2
Table of contents
Popular Laboratory Equipment manuals by other brands

LW Scientific
LW Scientific MX12 instruction manual

Waldmann
Waldmann ZAPP! Instructions for use

Metrohm
Metrohm 870 KF Titrino plus Installation and Tutorial

HACH LANGE
HACH LANGE TOC-X5 user manual

Waters
Waters Atlantis Premier BEH C18 AX Columns Care and use manual

Daheng Imaging
Daheng Imaging MARS quick guide