UV-C Bulb Replacement - Air Sniper Pro + Elite
The bulb light will flash once every 30 minutes once the bulbs have reached 10,944 hours of use (546 days 24/7) and the bulb light will turn red and unit
will shut off completely once it has reached 13,128 hours (547 days 24/7). You can order new bulbs on AirSniper.ca.
To access the bulbs, remove the 9
screws on side and top of the UVGI
Panel using a Phillips screwdriver.
1
2Remove the UVGI enclosure panel and set aside.
6Plug in the Air Sniper and turn the power on.
Enter the unique button reset code that was
sent with the bulbs.
2b(OPTIONAL) The middle 2 internal UVGI
elements can be removed to assist those with
larger hands in the removal of bulbs. WARNING:
DO NOT WASH THE UVGI ELEMENTS
3Pull out the bulb restraint clip that
secures the bulbs. Grip the tab at the
end and pull straight out.
Remove the burnt out or damaged bulb(s) and
recycle. Place the new bulb(s) in the socket
securely and replace the restraint clip.
Replace internal UVGI filters if they were
removed in step 2b.
4
5Replace the UVGI enclosure panel
and hand tighten the 9 screws so the
panel is securely fastened. WARNING:
Ensure there is a tight seal before turning
the power on to the unit. Exposure to UV
light can damage unprotected skin and eyes.
8