  9. Airport 705-425 User manual

Airport 705-425 User manual

®
MedProMedPro
Portable Nebulizer System
For Effective Delivery of Aerosol Medication
TM
Model: 705-425
INSTRUCTION MANUAL
Please keep this manual for future reference and for technical information.
2
TABLE OF CONTENTS
General Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Rechargeable Battery Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
About the Two-Valve Feature. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Product Parts Identification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-7
Setup Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-9
Powering Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-11
To Use With Rechargeable Battery Pack . . . . . . . . . . . . . . . . . . . 10
To Use With AC Adaptor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
To Use With Car Adaptor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Inhalation Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Cleaning Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Care and Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
5 Year Limited Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
®
Thank you for purchasing the MedPro AirPort™ Portable Nebulizer
System. It is a compact medical device designed to efficiently deliver
physician prescribed medication to the bronchial lung passages. With
proper care it will provide you with many years of reliable treatment.
This device is developed for use in the treatment of asthma, allergies and
other respiratory disorders. The pump creates a stream of compressed air
that is sent to the nebulizer. When the air enters the nebulizer, it will
convert the liquid solution of medication present in the nebulizer
chamber into an aerosol mist for easy inhalation.
This device can be used on adult or pediatric patients.
®
Your MedPro AirPort™ Portable Nebulizer System should be used
under the supervision of a licensed physician and / or a respiratory
therapist. We encourage you to thoroughly read this instruction manual
to learn about the features of this product. Any use of this device other
than its intended use should always be avoided.
INTRODUCTION
3
Before use, thoroughly read and understand this instruction manual.
Failure to read and observe all precautions could result in personal
injury or equipment damage.
• THIS DEVICE IS DESIGNED FOR AEROSOL THERAPY ONLY.
Any use for other purposes is inappropriate and therefore dangerous.
The manufacturer cannot be held responsible for damage resulting from
improper or abusive usage, nor if the device is used on electrical
installations that do not conform to the current standard specified in
this manual.
• Do not use the device in the presence of mixtures of anesthetics that
could ignite on contact with air, oxygen or nitrogen protoxide.
• In case of malfunction, turn off the device and consult this manual.
If the device continues to malfunction even if the instructions have
been followed, contact AMG’s Customer Service (1-800-363-2381).
NEVER OPEN THE COMPRESSOR’S MAIN UNIT.
• Do not use this product while bathing or in a humid environment such
as close to a bathtub. To avoid electrical shock, keep the unit away from
water. Do not immerse the power cord or the unit in liquid. Never reach
for a unit that has fallen into water – immediately unplug the unit.
• Never operate this device if feeling drowsy. Close supervision is required
when it is used by, on, or near children or compromised individuals.
• Always unplug the nebulizer immediately after use. Always keep the
unit and power cord away from heat.
• Unplug the nebulizer before filling. Do not overfill.
•This device will turn off automatically after approx. 20 minutes of
operation. To prevent over-heating and damage to the unit, allow it
to rest for about 40 minutes after every 20 minutes of operation.
•Always ensure that the inlet filter is dry for proper operation. If the
inlet filter becomes moist, replace it with a dry filter and allow the
wet filter to dry before using it again.
IMPORTANT: Always follow your doctor's instructions regarding the
type of drug, dosage, frequency, and duration of the inhalations.
GENERAL PRECAUTIONS
4
5
RECHARGEABLE BATTERY INFORMATION
PLEASE READ CAREFULLY BEFORE USING THE BATTERY.
1. You should fully charge your battery for at least 8 hours before using
it for the first time. Protect the battery from high temperatures when
charging, operating and storing.
2. For optimal charging efficiency, the battery should be charged at an
ambient temperature of 10~30°C. If battery is charged outside of the
recommended temperature range, you may notice erratic functioning
of the charging indicator light.
3. If the battery is used at an ambient temperature over 45°C, the
nebulizer may shut down automatically to prevent overheating.
If this occurs, allow the device and battery to cool down.
4. When the nebulizer power indicator light turns to orange (indicating
low power), detach the battery from the nebulizer until charging.
5. Only charge and recharge this battery with the AC adaptor supplied
with your nebulizer. DO NOT attempt to use any other device as it
may damage your battery and will void its warranty.
6. If the battery is not to be used for a long period of time, it should be
recharged every three (3) months to maintain optimal performance.
ABOUT THE TWO-VALVE FEATURE
The mouthpiece included with this unit
features a two-valve system. During expiration,
the expiration valve will open, allowing the
patient's exhaled air to pass to atmosphere,
avoiding contamination of the device. During
inspiration, the valve will close, maximizing
the amount of inhalation and reducing any
waste of drug to a minimum.
Inhaled air
Exhaled air
A. Nebulizer Chamber
Assembly
1. Nebulizer Cap
2. Micronization Cone
3. Nebulizer Chamber
B. Top Cover
C. Piston Compressor Unit
4. Air Inlet
5. Power Indicator Light
6. On / Off Button
7. AC/DC Power Socket
D. Rechargeable Battery Pack
8. Charging Indicator Light
E. Rubber Cushion
F. Air Tubing Assembly
G. Adult Mask
H. Pediatric Mask
I. Mouthpiece
J. Extension Connector
K. Air Outlet Filter (Round)
L. Air Inlet Filter (Strip)
M. Mask Adapter
N. AC Adapter
O. Car Adapter
P. Carrying Bag
A
1
2
3
G
H
PRODUCT PARTS IDENTIFICATION
6
PRODUCT PARTS IDENTIFICATION
7
B
5
4
6
7
8
C
D
E
F
IJ
K L M
NO
P
®
Before using your MedPro AirPort™
Portable Nebulizer System, always
ensure that all parts are clean, as later
described in this manual.
1. Remove top cover and mouthpiece
from the unit.
2. Rotate the nebulizer chamber
assembly counter-clockwise to
detach it from the unit (figure 1-1).
3. Loosen and pull up the nebulizer
cap to separate from the nebulizer
chamber assembly. Remove the
micronization cone (figure 1-2).
4. Ensure that the air filters are in
place (see "Care and Maintenance"
for filter replacement procedure).
Carefully pour the prescribed drug
into the nebulizer chamber, making
sure not to fill over the lower line
(figure 2). If the dose to be inhaled
is larger than 7 ml, it should be
divided into several separate
inhalations.
5. Insert the micronization cone into
the nebulizer chamber and put on
the nebulizer cap (figure 3-1).
6. Attach the nebulizer chamber
assembly to the unit by clockwise
rotation, making sure that it is
properly secured in place (figure 3-2).
SETUP INSTRUCTIONS
8
Figure 1-1 Figure 1-2
Figure 2
Do not
fill over
this line
Figure 3-2Figure 3-1
TO USE WITH MOUTHPIECE
Remove the mouthpiece from top
cover and install it on the nebulizer
chamber assembly at the angle best
suited for your needs (figure 4).
TO USE WITH MASK
Place the mask adaptor onto the
nebulizer chamber assembly and press
firmly to secure, and secure the mask
on the mask adaptor. Ensure a tight
seal before using (figure 5).
TO USE WITH AIR TUBING
1. Omit step 6 of the preparation.
2. Connect the extension connector
onto the piston compressor unit
(figure 6).
3. Link one end of the air tubing to
the top of the extension connector
(figure 7A) and insert the other end
into the bottom of the nebulizer
chamber assembly (figure 7B).
4. Attach the mouthpiece or mask
onto the nebulizer chamber
assembly as described above.
Note: To ensure proper nebulization,
keep the nebulizer chamber assembly
in an upright position during
treatment.
9
Figure 4 Figure 5
Figure 6 Figure 7
SETUP INSTRUCTIONS
B
A
RECHARGEABLE BATTERY PACK
The included rechargeable Ni-Cd battery
pack can provide approximately 40 to 50
minutes of treatment time before needing
to be recharged again. Note that the
nebulizer system needs 40 minutes of
cooling time after every 20 minutes of
operation to prevent overheating (the unit
will turn off after 20 minutes of operation).
1. To insert the battery, match the teeth
on the top of battery and grooves at the
bottom of the unit (A). Match the
polarities of the battery and device and
ensure the two indicator lights on the
device and battery face the same
direction after installation (B).
Note: Be careful to insert the battery
properly to avoid damage to the
connector.
2. To remove the battery, rotate the
battery pack clockwise and detach it
from the device.
3. To charge the battery Insert plug of the
AC/DC adaptor to the back of the
device. An orange light indicates the
battery is being recharged. The orange
light will be turned off once charging is
completed.
10
POWERING INSTRUCTIONS
A
B
Note: It is recommended to charge the battery for at least
8 hours before using it for the first time.
11
POWERING INSTRUCTIONS
AC ADAPTOR
1. Insert the adaptor in an electricity outlet which voltage matches that
of the adaptor. The specifications are indicated on the adaptor.
2. Insert the AC/DC adaptor plug into the unit’s power socket.
CAR ADAPTOR
1. Insert the plug of the car adaptor into the cigarette lighter socket.
2. Insert the other plug of the adaptor into the unit’s power socket.
NEVER USE THE NEBULIZER SYSTEM WHILE DRIVING.
INHALATION INSTRUCTIONS
1. Place the prepared nebulizer system in front of you. Start it by
pressing the ON/OFF button. A green light will appear, indicating
that the compressor is working normally. Note: an orange light
indicates that the battery needs to be recharged.
2. Inhale the drug as prescribed by your doctor. Only the nebulization
capsule and solution for aerosol therapy should be used for this
device. During inhalation, it is important that the device be kept in
the vertical position as this guarantees correct functioning of the
device and maximum effectiveness of the treatment.
3. Once the generated mist is no longer constant, it indicates that the
drug in the nebulizer chamber is running out; however, therapy
should be continued until there is no aerosol left at all.
IMPORTANT: As with most devices for aerosol treatment, at the end
of the inhalation, a certain amount of medication (about 0.95 ml) will
remain in the nebulizer chamber which is perfectly normal. This portion
of the drug, also called the residual volume, cannot be nebulized.
1212
CLEANING INSTRUCTIONS
®
In order to ensure the proper functioning of your MedPro AirPort™
Portable Nebulizer System, it should be thoroughly cleaned regularly.
AFTER EVERY INHALATION
1. Turn off the compressor by pressing the ON / OFF button. Remove
the battery block or unplug the power cord from the power outlet
and then from the unit.
2. Remove the mouthpiece (or mask, mask adapter, air tubing
assembly), nebulizer cap and micronization cone.
3. Rotate and take out the nebulizer chamber and clean all mobile
parts under running water.
4. Wipe the unit’s body by using a clean, moistened soft cloth.
IMPORTANT: Never clean with benzene, thinner or any other
flammable chemical.
5. Wash all other parts of the nebulizer system, especially the parts
that have been in contact with the nebulized drug (including the
mouthpiece, mask, mask adapter and/or air tubing assembly),
nebulizer, micronization cone and nebulizer chamber under
running water.
6. Rinse thoroughly all mobile parts (excluding the compressor unit
and battery pack) under lukewarm running water (max. 60 degrees)
for 10 minutes and wipe with a clean dry cloth.
7. Let air-dry completely and store in proper conditions until next use.
PERIODICALLY, TO REDUCE RISK OF INFECTION
Repeat all the procedures mentioned above. The mouthpiece, mask
adapter, complete nebulizer chamber assembly can be sterilized by
keeping in boiling water for 10 minutes. Do not boil the complete
device or any other parts.
REPLACEMENT OF NEBULIZER CHAMBER ASSEMBLY
In the packaging you will find one spare micronization cone that can be
used as replacement when necessary . Contact your device supplier or
call our customer service for other nebulizer chamber assembly parts.
REPLACEMENT OF THE AIR FILTERS
This unit features outlet and inlet air filters which ensure that the mist
generated contains no extraneous substances. Their replacement
frequency depends on the atmosphere conditions in which the device is
used (e.g. the amount of dust in the ambient air), but they should usually
be replaced after approximately 20 hours of usage or when discolored.
10 replacements filters (5 inlet and 5 outlet) are included with this
system. Additional filters can be purchased from your device supplier.
To change the filters:
1. Remove the nebulizer chamber
from the unit. Slide out the air
inlet cover from the front of the
unit (figure 8). Then, use a pointed
object to remove the filter.
2. Remove the outlet filter with your fingers.
3. Replace with new inlet and outlet
filters and slide back the air inlet cover.
CAUTION
Do not drop the nebulizer system as it is not shock proof.
Do not modify or disassemble the unit.
Do not clean with thinner, benzene or any other harsh cleaner.
Keep the device in a suitable place. Avoid high temperature, direct
sunlight, high humidity and dust.
1213
CARE AND MAINTENANCE
Figure 8
Air Outlet
Filter
Air
Inlet
Filter
TROUBLESHOOTING
The nebulizer system
does not operate.
The system is
turned on but does
not nebulize, or the
medication does not
nebulize properly.
The system
overheats.
The device is noisy.
The battery is not
working optimally.
The battery is not
charging.
14
1. Ensure that the chosen method of powering is
properly connected to the unit and to the
source of power.
2. Press the ON/OFF button again.
1. Ensure that the nebulizer is not empty and that
the micronization cone is properly seated in the
nebulizer chamber. If needed, clean or replace
the nebulizer chamber assembly.
2. Ensure that the nebulizer system is seated
and/or verify air tubing connection (repeat the
connection procedure as described on page 9).
3. Ensure that the nebulizer is in an upright
position during use. Do not tilt beyond 30°.
4. The air filters may be dirty or obstructed. If
needed, replace them as described on page 13.
If the internal temperature reaches the preset
level, the unit will automatically shut down to
prevent the unit from overheating. Allow it to
cool down for a minimum of 40 minutes.
Ensure that the filter cover is properly in place
and that it completely covers the filter seat.
Battery was not properly conditioned (charged for
at least 8 hours before first use). If it has been in
use for approximately four months, the battery
may need to be conditioned again.
Verify all power cord connections and cord
conditions, as well as the power outlet.
5 YEAR LIMITED WARRANTY
15
®
Your MedPro AirPort™ Portable Nebulizer System is warranted to the
original retail purchaser to be free from defects in material and
workmanship for a period of five (5) years from the date of purchase.
This warranty does not cover failures resulting from misuse, abuse or
alteration, use of improper components or failure to comply with the
operating and charging instructions. This warranty does not include the
nebulizer chamber assembly or accessories.
To make a warranty claim, please call customer service at AMG Medical,
1-800-363-2381. Once you have received a return authorization
number, return your nebulizer system, freight prepaid and insured to
AMG Medical Inc . 8505 Dalton, Montreal Quebec, Canada H4T 1V5.
All requests for warranty service should include the return authorization
number, proof of purchase (including date of purchase), your phone
number and address, and the nature of your service request. We will
either repair or replace free of charge any parts necessary to correct
defects in material or workmanship covered by this limited warranty.
This limited warranty is in lieu of all other warranties; i.e., oral, written,
express or implied. There are no warranties of merchantability or fitness
for a particular purpose, except for those implied warranties arising by
operation of law which are limited in duration to the five (5) year term of
this warranty. Liability, whether based on contract, tort, warranty, strict
liability, or any other theory, shall not exceed the price of the individual
nebulizer which is the basis of the claim. In no event shall we be liable
for any loss of profits, facilities, equipment or other incidental,
consequential or special damages.
TROUBLESHOOTING
If after reviewing the Troubleshooting list, the product does not
function properly, please call Customer Service at 1-800-363-2381.
Our representative will provide further instruction on how to correct
the trouble or will ask you to return it for repair or replacement.
SPECIFICATIONS
Power Supply: Adapter (100~240V, 50~60Hz; 15Vdc, 1.2A)
Power Consumption: Approx. 12W (12V/1A)
Sound Level: Below 70 dB
Particle Range(MMAD): 3.0~4.0
Nebulizer Capacity: 7ml
Flow Rate: 0.3 ml/min (NaCl 0.9%)
Intermittent Operation: 20 min ON/ 40 min OFF
Operation Conditions: 10~40 °C (50~40 °F ); RH 10~95%
Storage Conditions: -25~60 °C (-13~140°F ); RH 10~95%
Dimensions: Approx. 86 mm x 45 mm x 124 mm (3.4” x 1.8” x 4.9”)
or 86 mm x 45 mm x 180 mm
(3.35” x 1.77” x 7.09”) with battery pack
Weight: Approx 345g (12.17 oz)
or 620g (21.87 oz) with battery pack
Accessories included:
Pediatric Mask, Adult Mask, Mouthpiece, Mask Adapter, Air Tubing Assembly,
5 Spare Inlet Filters, 5 Spare Outlet Filters, Spare micronization cone,
Rechargeable Battery Pack, Carrying Bag, Rubber Cushion, Switching Adapter
Classification: Class IIa, Type B
IPX0 - no protection against harmful ingress of water.
Not suitable for use in the presence of a flammable anesthetic, oxygen or
nitrogen protoxide.
Precautions:
Power: Only use an adapter designed for the product
Standard---Switching Adapter, Rating: 100-240Vac 50-60Hz/15Vdc1.2A
Standard ---Car Adapter, Rating: Fuse 3A/250V, Wire 22AWG x150cm
Rechargeable Battery Pack, Rating: 1.2V x 800mAh x 10
Questions? Comments? 1-800-363-2381
Made in Taiwan for : AMG MEDICAL INC.
8505 Dalton, Montreal, QC H4T 1V5
www.amgmedical.com
REV 1 0306 P/N 815-146

Popular Respiratory Product manuals by other brands

Bullard CC20E Series instruction manual

Bullard

Bullard CC20E Series instruction manual

cleanAIR Chemical 2F operating instructions

cleanAIR

cleanAIR Chemical 2F operating instructions

Hillrom Breathe LIFE2000 Instructions for use

Hillrom

Hillrom Breathe LIFE2000 Instructions for use

cleanAIR AerGO user manual

cleanAIR

cleanAIR AerGO user manual

HOMEAIDE Easy Neb Guide book

HOMEAIDE

HOMEAIDE Easy Neb Guide book

INTERSPIRO DIVATOR Series user manual

INTERSPIRO

INTERSPIRO DIVATOR Series user manual

Sundstrom SR570 User instructions

Sundstrom

Sundstrom SR570 User instructions

Sundstrom SR 500 Instructions for use

Sundstrom

Sundstrom SR 500 Instructions for use

Sunset Healthcare NEB402 instruction manual

Sunset Healthcare

Sunset Healthcare NEB402 instruction manual

Air Liquide Respireo SOFT Baby user guide

Air Liquide

Air Liquide Respireo SOFT Baby user guide

Sleepnet Phantom 2 manual

Sleepnet

Sleepnet Phantom 2 manual

NIOSH 3M 8246 User instructions

NIOSH

NIOSH 3M 8246 User instructions

Apex Digital Mobi Mesh instruction manual

Apex Digital

Apex Digital Mobi Mesh instruction manual

Respirex SIMH024 instruction manual

Respirex

Respirex SIMH024 instruction manual

ResMed Full Face Mask Mirage Quattro user guide

ResMed

ResMed Full Face Mask Mirage Quattro user guide

Baynhams PeRSo 3.0 user manual

Baynhams

Baynhams PeRSo 3.0 user manual

Gima EOLO instruction manual

Gima

Gima EOLO instruction manual

Sundstrom SR 500 manual

Sundstrom

Sundstrom SR 500 manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.