AKG PSU 4000 - User manual

Bedienungsanleitung. . . . . . . . . . . . . . . S. 2
Bitte vor Inbetriebnahme des Gerätes lesen!
User Instructions. . . . . . . . . . . . . . . . . . p. 6
Please read the manual before using the equipment!
Mode d’emploi. . . . . . . . . . . . . . . . . . . . p. 9
Veuillez lire cette notice avant d’utiliser le système!
Istruzioni per l’uso. . . . . . . . . . . . . . . . p. 13
Prima di utilizzare l’apparecchio, leggere il manuale
Modo de empleo . . . . . . . . . . . . . . . . . p. 16
¡Sirvase leer el manual antes de utilizar el equipo!
Instruções de uso . . . . . . . . . . . . . . . . p. 20
Por favor leia este manual antes de usar o equipamento!
PSU 4000
WMS4000
wireless microphone system
power supply

1 Safety and Environment
1.1 Safety
1.2 Environment
2.1 Introduction
*Refer to figs. 3 and 4. See
SR 4000 manual for details.
2.2 Unpacking
6PSU 4000
1. Do not spill any liquids on the equipment and do not drop any objects through the ventilation slots in
the equipment.
2. The equipment may be used in dry rooms only.
3. The equipment may be opened, serviced, and repaired by authorized personnel only. the equipment
contains no user-serviceable parts.
4. Before connecting the equipment to power, check that the AC mains voltage stated on the equipment
is identical to the AC mains voltage available where you will use the equipment.
5. To avoid the risk of electric shock, make sure to connect the equipment to a grounded power outlet.
It is illegal to disconnect the protective ground wire or use a non-standard power plug.
6. Prior to connecting receivers to the equipment, compare the output voltage of the equipment with the
operating voltages of all receivers. Only connect receivers operating on the same voltage, type of
current (AC or DC), and having the same connector polarity as the outputs on the PSU 4000.
7. The current drain on the DC OUT 1 output of the equipment must never exceed 2.5 A, the current
drain on outputs DC OUT 2 and DC OUT 3 must never exceed 2 A.
8. Never short any of the equipment's outputs!
9. Never apply any voltage to any of the equipment's outputs. Never connect any type of power supply
to a PSU 4000 output. This may cause damage to both the equipment and the power supply.
10.If any solid object or liquid penetrates into the equipment, shut down the sound system immediately.
Disconnect the power cable from the power outlet immediately and have the equipment checked by
AKG service personnel.
11.If you will not use the equipment for a long period of time, disconnect the power cable from the power
outlet. Please note that the equipment will not be fully isolated from power when you set the on/off
switch to OFF.
12.Do not place the equipment near heat sources such as radiators, heating ducts, or amplifiers, etc. and
do not expose it to direct sunlight, excessive dust, moisture, rain, mechanical vibrations, or shock.
13.To avoid hum or interference, route all cables away from high-voltage lines of any type.
14.Clean the equipment with a moistened (not wet) cloth only. Be sure to disconnect the power cable
from the power outlet before cleaning the equipment! Never use caustic or scouring cleaners or clean-
ing agents containing alcohol or solvents since these may damage the enamel and plastic parts.
15.When routing cables, make sure that nobody can trip over them.
16.Do not use any accessories except those recommended by AKG.
17.Do not use the equipment for any applications other than those described in this manual. AKG can-
not accept any liability for damages resulting from improper handling or misuse.
1. When scrapping the equipment, separate the case, circuit boards, and cables, and dispose of all com-
ponents in accordance with local waste disposal rules.
2. The packaging of the equipment is recyclabe. To dispose of the packaging, make sure to use a col-
lection/recycling system provided for that purpose and observe local legislation relating to waste dis-
posal and recycling.
Thank you for purchasing an AKG product. This Manual contains important instructions for setting up and
operating your equipment. Please take a few minutes to read the instructions below carefully before
operating the equipment. Please keep the Manual for future reference. Have fun and impress your audi-
ence!
The PSU 4000 is a power supply with three 12 V DC outputs for powering a WMS 4000 multichannel sys-
tem. The unit features a 1-U 19" case for rack mounting*.
The PSU 4000 replaces the AC adapters that come with the various WMS 4000 components and thus
greatly simplifies the setting up of multichannel wireless systems.
Check that the packaging contains all of the components listed above. Should anything be missing,
please contact your AKG dealer.
2 Description
1 PSU 4000 1 IEC power cable 3 connecting cables
with DC connectors 1 19" rack mount kit

2.3 Controls
2.3.1 Front Panel
Fig. 1: Front panel controls and
indicator LEDs.
Refer to fig. 1.
2.3.2 Rear Panel
Fig. 2: Rear panel inputs and out-
puts.
Refer to fig. 2.
Refer to fig. 5.
Refer to fig. 5.
Important!
Important!
Important!
3.1 DC Connections
Connect PS 4000 with antenna
system to DC OUT 1 only!
Important!
3.2 Connecting to Power
Warning!
The power supply front panel provides the following controls and indicators:
ON/OFF: Press this key to switch power to the unit ON. Press again to switch power to the unit OFF.
DC OUT 1 - 3: The blue OK LED will be lit for as long as the assigned DC output DC OUT 1, 2, or 3 pro-
vides the correct supply voltage for active components.
Should the supply voltage at a DC output be shorted or fail (drop below 2 V), the output be over-
loaded, or the temperature of the unit exceed the acceptable level, the OK LED for that input will
extinguish and the red FAIL LED be lit instead.
The PSU 4000 rear panel provides the following inputs and outputs:
IEC receptacle accepting the matching connector on the supplied power cable. The IEC receptacle
incorporates a standard fuse holder with a 2 A slow-blow fuse. The PSU 4000 uses a wide-range
power transformer for primary voltages from 90 VAC to 264 VAC.
DC OUT 1: DC output jack with a load capacity of up to 2.5 A for connecting a PS 4000 with an anten-
na system and up to four SR 4000 receivers (the receivers are powered via the antenna cables) or
one other WMS 4000 component (HUB 4000, HPA 4000, CU 4000).
DC OUT 2, DC OUT 3: DC output jacks with a load capacity of up to 2 A for connecting a WMS 4000
component (SR 4000, HUB 4000, HPA 4000, CU 4000, PS 4000 with no antenna system).
Make sure the total current consumption of all components connected to DC OUT 1 does
not exceed 2.5 A and the total current consumption of all components connected to DC
OUT 2 or DC OUT 3 does not exceed 2 A. Higher loads can cause damage to the PSU 4000
due to overheating.
Do not connect the unit to power before you have made all audio and DC connections.
Check that the output voltage of the PSU 4000 is identical to the operating voltage of the
components your about to connect. Operating components on an incorrect voltage may
damage both the compponents and the PSU 4000.
1. Use the supplied connecting cables to connect the DC OUT jacks on the rear panel of the PSU 4000
to the DC input jacks on the desired components.
2. Each connecting cable has a ferrite core attached near one end. Make sure to connect this end of
each cable to the PSU 4000.
Never plug a connecting cable into an unused DC OUT jack. The unused DC connector on
the cable may be shorted by metal parts.
The PSU 4000 features a wide-range power transformer for primary voltages from 90 VAC to 264 VAC.
Therefore, you can connect the unit to any power outlet with an AC voltage within this range and a fre-
quency between 47 Hz and 63 Hz.
1. Use the supplied power cable to connect the PSU 4000 to a convenient power outlet.
To avoid the risk of electric shock, make sure to connect the equipment to a grounded
power outlet.
7
PSU 4000
2 Description
3 Setting Up

3.3 Powering Up and
Powering Down
3.4 Fuse
Warning!
Important!
6.1 Input
6.2 Outputs
6.3 System
6.4 Standards
8PSU 4000
1. To power up, press the ON/OFF key.
The three DC OUT OK LEDs will be lit.
The power LEDs (if any) on the components connected to the PSU 4000 will light if the components
are on.
For details on operating WMS 4000 components, refer to the appropriate manuals.
2. To power down, press ON/OFF again.
Make sure to replace the fuse integrated in the IEC receptacle with a fuse of the same
type (2 A slow-blow only. Other types of fuses may cause malfunctioning or a risk of fire.
1. Disconnect the AC adapter from the power outlet.
2. Use a cloth moistened (not wet!) with water to clean the surfaces of the equipment.
Never use caustic or scouring cleaners or cleaning agents containing alcohol or solvents
since these may damage the enamel or plastic parts.
Input voltage 90 VAC to 264 VAC
Frequency 47 to 63 Hz
Output voltage 3 outputs, 12 VDC each
Max. output current DC OUT 1: 2.5 A, DC OUT 2-3: 2 A
Weight: 1.3 kg (3.2 lbs.)
Size 200 x 190 x 44 mm (7.8 x 7.5 x 1.7 in.)
This equipment fulfills the following European standards:
NE 300422-2 V1.1.1
NE 301489-9 V1.3.1.
EN 60065:2002
EN 61000-3-2:2000
EN 61000-3-3:1995/A1:2001
3 Setting UP
4 Cleaning
5 Troubleshooting
None of the front panel LEDs is lit.
Connected cmponent(s) fail(s) to function
although associated OK LED(s)
is (are) lit.
One of the FAIL LEDs is lit.
1. PSU 4000 is not connected to power.
2. PSU 4000 is OFF.
3. Fuse on the distribution fuse board is
blown.
4. Fuse on PSU 4000 is blown.
5. PSU 4000 is defective.
1. Connected component(s) is (are) off.
2. DC connector on connecting cable is not
plugged all the way in.
3. Connecting cable is defective.
4. Incorrect voltage (component defective).
5. Incorrect polarity (component defective).
1. DC output is shorted.
2. DC output is overloaded.
3. Unit is overheated.
4. Connecting cable or connected
component is defective.
5. Internal error.
1. Connect PSU 4000 to power.
2. Switch PSU 4000 ON.
3. Check fuse.
4. Replace fuse with fuse of same type (2 A
slow-blow).
5. Disconnect all connecting cables from DC
OUT jacks. If LEDs fail to illuminate, con-
tact your nearest AKG Service Center.
1. Switch component(s) on.
2. Disconnect connecting cable and plug
connector all the way into DC OUT jack.
3. Replace connecting cable.
4. Contact your nearest AKG Service Center.
5. Contact your nearest AKG Service Center.
1. Eliminate the short.
2. Check connected load:
Total current consumption of all connected
components msut not exceed 2.5 A
(DC OUT 1) or 2 A (DC OUT 2-3).
3. Check ventilator, check connected load,
place unit in a cooler location.
4. Disconnect cable. If OK LED illuminated,
replace connecting cable or have compo-
nent checked by AKG Service.
5. Contact your nearest AKG Service Center.
Problem Possible Cause Remedy
6 Specifications

11
PSU 4000
Notizen • Notes • Notes • Note • Notas • Notas
Fig. 3
A
B
C
PSU 4000
PS 4000/1
DC
DC
DC
100-240V AC/2A
RF
RF
RF
RF
DC+RF
DC+RF DC+RF
DC+RF
DC+RF
DC+RF DC+RF
DC+RF
DC+RF
DC+RF DC+RF
DC+RF
SR 4000 / 1-4 SR 4000 / 9-12
SR 4000 / 5-8
PS 4000/3PS 4000/2
PSU 4000
!
Fig. 5
D
Fig. 4
ABC
2186_03_PSU_Umschlag_fsch 13.10.2003 11:14 Uhr Seite 2

Technische Änderungen vorbehalten. Specifications subject to change without notice.
Mikrofone · Kopfhörer · Drahtlosmikrofone · Drahtloskopfhörer · Kopfsprechgarnituren · Akustische Komponenten
Microphones · Headphones · Wireless Microphones · Wireless Headphones · Headsets · Electroacoustical Components
Printed in Austria on recycled paper. 08/03/9100 U 1060
AKG Acoustics GmbH
Lemböckgasse 21–25, P.O.B. 158, A-1230 Vienna/AUSTRIA, Tel: (+43 1) 86 654-0*, Fax: (+43 1) 86 654-7516, www.akg.com, e-mail: sal[email protected]
AKG Acoustics GmbH
Bodenseestraße 228, D-81243 München/GERMANY, Tel: (+49 89) 87 16-0, Fax: (+49 89) 87 16-200, www.akg-acoustics.de, e-mail: info@akg-acoustics.de
AKG ACOUSTICS, U.S.
914 Airpark Center Drive, Nashville, TN 37217, U.S.A., Tel: (+1 615) 620-3800, Fax: (+1 615) 620-3875, www.akgusa.com, e-mail: ak[email protected]
For other products and distributors worldwide see our website: www.akg.com
Bedienungsanleitung . . . . . . . . . . . . . . . S. 2
Bitte vor Inbetriebnahme des Gerätes lesen!
User Instructions. . . . . . . . . . . . . . . . . . . p. 6
Please read the manual before using the equipment!
PSU 4000
WMS4000
wireless microphone system
power supply
2186_03_PSU_Umschlag_fsch 13.10.2003 11:14 Uhr Seite 1
Other manuals for PSU 4000 -
1
Table of contents
Other AKG Microphone System manuals

AKG
AKG WMS 470 - SERVICE User manual

AKG
AKG WMS 470 - SERVICE User manual

AKG
AKG SR 40 DIVERSITY User manual

AKG
AKG WMS 450 - SERVICE User manual

AKG
AKG SPC 4 User manual

AKG
AKG DMS 70 Quattro User manual

AKG
AKG WMS 40 MINI User manual

AKG
AKG DMS 700 User manual

AKG
AKG HT 81 User manual

AKG
AKG WMS 40 PRO FLEXX User manual

AKG
AKG Perception WMS45 User manual

AKG
AKG DMS Tetrad User manual

AKG
AKG WMS 4000 User manual

AKG
AKG PW45 User manual

AKG
AKG PT 300 User manual

AKG
AKG SR 40 DIVERSITY User manual

AKG
AKG SR 40 DIVERSITY User manual

AKG
AKG Drum Set Concert I User manual

AKG
AKG WMS 40 PRO FLEXX User manual

AKG
AKG HT 4000 User manual