The Alcatel-Lucent 1511 BA is a 2 Mb/s 30-channel multiservice access multiplexer, which can be used across
a wide range of companies for business access and utility network applications. It also provides grooming func-
tionalities for GSM and wireless local loop networks. For example, railway networks, pipelines for oil, gas and
water and power utilities use utility network applications with different sets of service requirements. Whereas
railway and pipeline installations require a linear or ring type of network with drop-and-insert functions, other
installations require a mesh type of network. For all of these applications the Alcatel-Lucent 1511 BA offers
the ideal solution.


Features
• Channelbankfor30x64kb/schannels
• 2Mb/sG.703/G.704aggregates
• Varietyoftributaryboardsforvoice,
data and Ethernet
• Localorremotecraftterminaland
centralized element management
platform
• Drop-and-insertfacilityat64kb/s
granularity
• Voiceanddataconferencecircuits
• Built-inringinggeneratorand12
or 16 kHz metering pulses for coin
boxes and private meters
• SupportforincorporationofPDH
terminal units for transport of E1
streams over optical fiber and cop-
percable(G.shdsl)
• AutomatictrailprotectionofNx
64 kb/s payload
• 48VDCpowersupplyor110VAC
or220VACwithoptionalbattery
backup
• RedundantDC/DCorAC/DC
conversion
Benefits
• Protectionofbusiness-criticalservices
with high reliability, APS and trail
protection
• Easeofupgradingwithamodular
architecture for rapidly growing
or changing networks
• Fullsoftwarecontrolofnetwork
configuration, maintenance and
supervision
Network Element Management
Fast,efcientandexiblemanagement
is the key to success for any network.
Alcatel-Lucent’s network management
software,basedonITU-TM.3010,
satisfies all three of these criteria in an
easy-to-learn and easy-to-use package.
Network management of all elements
in a system is performed from a single
terminalcomprisingacompatiblePC
running Windows or a workstation
loaded with Alcatel-Lucent network
management software.
Alcatel-Lucent 1511 BA | 2 Mb/s 30-Channel Primary Rate Multiplexer2
Architecture
ThePCMController(PCMC2)interfaces
the users and the E1 aggregate side.
The controller connects the analog,
data or N x 64 kb/s data terminal
channels of the tributary boards,
orthePCMC2inslavemode,tothe
2,048kb/sG.703/G.704aggregate
via an internal serial bus.
ThePCMC2provides:
• Atransmission/switchinginterface
andHDB3tobinarycoding/decod-
ing, retiming, frame alignment and
supervision, cyclic redundancy check
#4(CRC4)generation/monitoring,
channelmapping,CAS,alarmtreat-
ment and test facilities
• Anasynchronousserialcommuni-
cation channel to a central alarm
supervising unit through which the
user can communicate about equip-
ment configuration, status and alarms
• Twoserialchannelsforembedded
operationchannel(EOC).These
channels can be used for transport
of network management protocols
between the network element and
its centralized management units.
PowerunitboardsforDC/DCandAC/
DCconversionareprovidedforeach
subrack assembly and can be dupli-
cated for redundancy.
Applications
POTS Subscriber Multiplexer
The POTS subscriber multiplexer is used
in the subscriber network and allows a
exiblemixofvoiceanddatainter-
faces. Adaptation of the signaling to
the customer’s requirements can be
done easily.
ISDN-BRI
The Alcatel-Lucent 1511 BA can be
usedforISDN-BRIapplications.Both
2-and4-wire(Uwithlinecode2B1Q
and S0/I.430) interfaces are available.
Each interface uses three timeslots
(2B+D16/M)onthe2Mb/sG.703link.
Hot Line
Hot Line is a bi-directional application,
with a centralized battery set, where
one subscriber hooks off and the other
is called without dialing. It uses the
same board as the POTS application.
This board’s lines can be programmed
either as a POTS or Hot Line.
Ringdown
ManualRingdown(MRD)isanAlcatel-
Lucent 1511 BA application that permits
the connection of two local battery
(LB) telephone sets or the connection
of a local battery telephone set to a
central switch board. This application
is widely used by stock market brokers.
It requires the use of a special ring-
down board.
Direct Dialing In
The Alcatel-Lucent 1511 BA provides
directdialingin(DDI),afeaturewhereby
the dialing information is sent directly
from the PSTN to the PABX, which
then sets up the connection to the
PABX subscriber.
Data Multiplexer
The Alcatel-Lucent 1511 BA can be used
as a data multiplexer. The possible data
tributaries are:
• 64kb/sG.703co-directional—with
optionalE&Msignaling
• 64kb/sG.703contra-directional
• 2Mb/sandNx64kb/sG.703/G.704.
(fractional E1)
• Lowspeed:75b/sto64kb/sforV.36,
V.35,V.28andX.21
• Nx64kb/s(N=1to31);interfaces:
V.35,V.36andX.21
Remote Data Unit
The Alcatel-Lucent 1511 BA provides an
integrated digital interface to remote
dataunits(RDUs).TheRDUsareprovided
with one or two of the following inter-
facesinanycombination:V.35,V.36,X.21
andV.24/V.28upto128kb/s,analog
and64kb/sG.703co-directionalinter-
faces. Performance monitoring on the
RDUisforeseenonthedigitallink.
High Quality Audio Tributaries
The Alcatel-Lucent 1511 BA can per-
form unidirectional audio transmission.
ThisaudioboardusesMPEG-215kHz
sampling.
2/4-Wire Audio Interface
Connectionbetweenanalogmodems
or PABX ports for tie-line connections
canbeachievedwiththe2/4-wire
audioboard.Variantswithorwithout
E&Mwiresareavailable.
Conference Bridge
Two types of conferences are possible:
• Master-slaveconference:Onepartic-
ipant is considered the “master” and
all others are considered “slaves.”
Onemasterwithupto29slavesis
possible.
• Fullconference:Thistypeofconfer-
ence is used when all participants
need to share information equally.
Every participant receives informa-
tion from all other participants but
himself or herself.
These two types of conferences can be
used for voice, data or signaling.
The conference bridge is a simple and
useful board in networks with super-
visory control and data acquisition
(SCADA)and/oraudiodispatching
requirements.
Dry Relay Contacts
This board has a number of detectors
for dry relay contacts. It is used for
collecting alarm indications of col-
located equipment and enables the
visualization of alarm states on the
same craft terminal or server as that
being used for the multiplexer
functions.
Integrated Optical Transport
BoardsforopticalPDHtransportof
4 or 16 E1 streams can be plugged into
the Alcatel-Lucent 1511 BA subrack and
managed by the same management
tools.SeetheAlcatel-Lucent1521FL
andtheAlcatel-Lucent1531FL.
Alcatel-Lucent 1511 BA | 2 Mb/s 30-Channel Primary Rate Multiplexer | Data Sheet 3
CCTV Camera
SCADA PLC
2 Mb/s
G.703
2 Mb/s
G.703
PABX
Transport
64 kb/s
Satellite Offices
Controls
Tie Line
Alarms and Data
LAN
ab PABX Line
ab HotLine
CCTV Monitor
and Control
SCADA
Host
PABX
Main Office
Tie Line
Server
LAN
ab PABX Line
ab HotLine
1511 BA 1511 BA
1515 CXC
ISDN-BRA
Remote 2x64 kb/s; 128 kb/s and A-LL
FE1 (G.703)
ab (2Wire)
S0 (4Wire)
Uko (2Wire)
U (2Wire)
10/100 Mb/s
ab (2Wire)
V.35/V.36/V.28/X.21
64 kb/s-G.703
V.35/V.36/X.21
2Wire
4/2Wire
Ethernet
ISDN-BRA
PSTN/Hotline/Payphone
PABX
VAM
Magneto Set
64 kb/s-LL and V.110 Subrate
Co- and Contra 64 kb/s
Nx64 kb/s-LL
Hifi-Audio
Analog-LL Modem
LAN
1511 BA
Figure 2. Alcatel-Lucent 1511 Typical Applications
Figure 1. Alcatel-Lucent 1511 BA User Interfaces
Automatic Protection Switch
The automatic protection switch (APS)
enables route protection on E1 level.
If used, the Alcatel-Lucent 1511 BA
transmits data via two different E1
routes. At the receive side, data coming
from the preferred route is used; if this
route fails, data is taken from the
other side.
Ethernet Switching
On an E1 trail across multiple Alcatel-
Lucent 1511 BA multiplexers, a group
of 64-kb timeslots (N: 1...31) is reserved
to carry Ethernet frames. In each Alcatel-
Lucent 1511 BA, one 10/100Base-T LAN
board (LANtrib) can drop/insert its local
Ethernet traffic onto these reserved
timeslots. To connect multiple Ethernet-
based end devices, the LANtrib offers
five external RJ-45 interfaces. The
LANtrib also switches LANs across mul-
tiple and distinct Alcatel-Lucent 1511
BA multiplexers. Switching between
the local five Ethernet ports runs at
wire speed.
Technical Specifications
Main Characteristics
 




Clock Synchronization
 
 
 





Mechanical Design
 


 



 






 

 

 






 

Power Supply
 
 
Environment




 



EMC
 


 

www.alcatel-lucent.com





Other Alcatel-Lucent Multiplexer manuals

Alcatel-Lucent 1643 AMS User manual

Alcatel-Lucent

Alcatel-Lucent 1643 AMS User manual

Alcatel-Lucent 1645 AMC User manual

Alcatel-Lucent

Alcatel-Lucent 1645 AMC User manual

Alcatel-Lucent Data Multiplexer Explore 1665 User manual

Alcatel-Lucent

Alcatel-Lucent Data Multiplexer Explore 1665 User manual

Alcatel-Lucent Data Multiplexer Explore 1665 User manual

Alcatel-Lucent

Alcatel-Lucent Data Multiplexer Explore 1665 User manual

Alcatel-Lucent 1660 User manual

Alcatel-Lucent

Alcatel-Lucent 1660 User manual

Alcatel-Lucent 1643 AMS User manual

Alcatel-Lucent

Alcatel-Lucent 1643 AMS User manual

Alcatel-Lucent 1645 AMC User manual

Alcatel-Lucent

Alcatel-Lucent 1645 AMC User manual

Alcatel-Lucent Data Multiplexer 1665 DMX User manual

Alcatel-Lucent

Alcatel-Lucent Data Multiplexer 1665 DMX User manual

Alcatel-Lucent Data Multiplexer Explore 1665 User manual

Alcatel-Lucent

Alcatel-Lucent Data Multiplexer Explore 1665 User manual

Alcatel-Lucent 1643 AMS Technical manual

Alcatel-Lucent

Alcatel-Lucent 1643 AMS Technical manual

Alcatel-Lucent 3600 MainStreet Operation and maintenance manual

Alcatel-Lucent

Alcatel-Lucent 3600 MainStreet Operation and maintenance manual

Alcatel-Lucent 1643 AMS User manual

Alcatel-Lucent

Alcatel-Lucent 1643 AMS User manual

Alcatel-Lucent 1643 AMS User manual

Alcatel-Lucent

Alcatel-Lucent 1643 AMS User manual

Alcatel-Lucent Data Multiplexer Explore 1665 User manual

Alcatel-Lucent

Alcatel-Lucent Data Multiplexer Explore 1665 User manual

Alcatel-Lucent 7330 Installation and operation manual

Alcatel-Lucent

Alcatel-Lucent 7330 Installation and operation manual

Alcatel-Lucent 1655 AMU User manual

Alcatel-Lucent

Alcatel-Lucent 1655 AMU User manual

Popular Multiplexer manuals by other brands

Case Communications 3200 Operation manual

Case Communications

Case Communications 3200 Operation manual

Robotic Bean Creative TM-1 user guide

Robotic Bean Creative

Robotic Bean Creative TM-1 user guide

Black Box MX880A manual

Black Box

Black Box MX880A manual

elink LNK-MVHD-102 Series quick start guide

elink

elink LNK-MVHD-102 Series quick start guide

Agilent Technologies 34921A user guide

Agilent Technologies

Agilent Technologies 34921A user guide

Tektronix KEITHLEY 7708 Instructions for use

Tektronix

Tektronix KEITHLEY 7708 Instructions for use

OCENAV ATM 105-A3 Quick installation guide

OCENAV

OCENAV ATM 105-A3 Quick installation guide

Quick Eagle Networks DL3800E user guide

Quick Eagle Networks

Quick Eagle Networks DL3800E user guide

Agilent Technologies E1470A Series user manual

Agilent Technologies

Agilent Technologies E1470A Series user manual

Pickering PXI Power MUX BRIC 40-571 manual

Pickering

Pickering PXI Power MUX BRIC 40-571 manual

Dallas Semiconductor MAXIM DS3112 manual

Dallas Semiconductor

Dallas Semiconductor MAXIM DS3112 manual

Quadra Plus VPU100 manual

Quadra Plus

Quadra Plus VPU100 manual

LITEWAY LiteLink VT-8004 operating instructions

LITEWAY

LITEWAY LiteLink VT-8004 operating instructions

GE StoreSafe Pro user manual

GE

GE StoreSafe Pro user manual

Kathrein BN 20610071 user manual

Kathrein

Kathrein BN 20610071 user manual

METRObility Optical Systems Radiance CWDM System Installation & user guide

METRObility Optical Systems

METRObility Optical Systems Radiance CWDM System Installation & user guide

ADTRAN Frameport 768 Specifications

ADTRAN

ADTRAN Frameport 768 Specifications

GE JungleMUX 86445-31 Technical practice and Installation manual

GE

GE JungleMUX 86445-31 Technical practice and Installation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.