9
AODDpumpsmustnotbeoperatedwithapositivesuctionpressure.
Dependingontheconditionsofoperation,theliquidconveyedmightescapefromthe
pumpthroughthemufflerincaseofadiaphragmrupture(inthiscasemufflerhastobe
replaced).Forfurthersafetyrequirementstheoptionalequipmentdiaphragmmonitoring
andbarrierchambersystemarerecommended.
Incaseofadiaphragmrupture,itmightbepossibleforthefluidpumpedtointrudeinto
theairsideofthepump.Inveryadverseconditions‐e.g.pressurewithinthefluidsystem
duringstoppedairsupply‐thefluidmightaswellfinditswayintotheairsupplylines.To
protectotherdeviceslikepulsationdampersorevenpneumaticvalves,itis
recommendedtoprotecttheairsupplylineaccordingly,e.g.viaanon‐returnvalve.This
wouldaswellavoidpollutingtheairsupplyline.
Thestateofthemufflerhastobeinspectedregularly,asablockedmufflercanbeforced
outofthepump.Ifthishappens,damagesofpropertiesand/orpersonscannotbe
excluded.
Iftheproducttendstosettle,thepumphastobeflushedregularly.Forlargersolidsa
filterhastobeinstalledinthesuctionline.
Incaseofdeliveryofhotliquidsthewettedpumpmustnotstandstillforalongertime,
becauseitcouldleadtotemporaryleaksinthevalveareaandtoablockadeoftheair
controlsystem.
Therelevanteffectivesecurityadviseshavetoberespected.
Poolsofliquidwhichappearinthenearouterareaofthepumphavetobeinspectedon
dangerpotential,ifnecessarysafetymeasuresaretobetaken.
Chemicalandbiologicalreactionsintheproductchamberofthepump(mixtureof
differentsubstances)andthefreezingoftheliquidhavetobeavoided.
Beforestartingtodisassemblethepump,takecarethatthepumphasbeenemptiedand
rinsed.Bothportspipingaretobeclosedanddrainedifapplicable.Furtherthepumphas
tobecutofffromanyenergyontheairandproductside.Ifthepumpisbeingdeported
fromtheplant,areferenceaboutthedeliveredliquidhastobeattached.Atemplateis
availableontheAlmatecwebsite.
Pleaserespecttherelevantadditionalsecurityadvices,ifthepumphasbeenusedfor
aggressive,dangerousortoxicliquids(e.g.suitableprotectiveequipmentaccordingto
thesafetydatasheetoftheliquid).Incaseofadiaphragmrupture,itispossiblethat
residuesoftheliquidremainbehindthediaphragms,intheareaoftheaircontrolsystem
andatthemuffler,despiteofseveralflushingprocesses.Hence,appropriatesafety
equipmentaccordingtothesafetydatasheetoftheliquidisindispensable.
Beforeputtingthepumpbackintooperation,thetightnessofthepumphastobe
checked.
PumpsoftheBIOCORseriesmustnotbesubmerged.
Air‐operateddiaphragmpumpscanleadtobruiseswhenlifting,sinkingorassembling
them.Appropriateaccessoriesandsafetyequipmentsaretobeused.Bigandheavy
moduleshavetofixedandsecuredtoliftinggearswhentransporting/replacingthem.
Especiallywhendelivercriticalliquids,wearparts,likediaphragms,shouldbereplaced
withinapreventivemaintenance.
Theuseofnon‐originalALMATECsparepartsandstructuralchangesleadtothelapseof
thewarrantyimmediately.Whenoperatingsuchapump,damagesofpropertiesand/or
personscannotbeexcluded.
Theoperationofthepumpwithnitrogenasdrivinggasispossible.Inclosedrooms
sufficientventilationmustbeprovided.
Possibleelectricalconnections(e.g.whenusingoptionalequipmentwithcontrollers)may
beexecutedbyaqualifiedpersononly.Theregulationsoftherespectivemanufacturers
aretobefollowed.
Atanyworkarisingithastobemadesurethatnoexplosiveatmospherecanappear.
Appropriatesafetyequipmentisrecommended.