Alotcer AD2066L User manual

AD2066L IP Mode
m User Manual
Web:en.alotcer.com Add:NO.146-148, 2nd XingBei Road, JiMei District, XiaMen, China.
AD2066L IP Modem User Manual
Support 2G/3G/4G Data Transfer Unit
Xiamen Alotcer Communication Technology Co., Ltd.
Tel:+86 592-6195619
Fax:+86 592-6195629
Web:en.alotcer.com
E-mail:[email protected]
Add:NO.146-148, 2nd XingBei Road, JiMei District,
XiaMen,China.

AD2066L IP Mode
m User Manual
Web:en.alotcer.com Add:NO.146-148, 2nd XingBei Road, JiMei District, XiaMen, China.
Applicable Models:
Product Type
Model
Product Name
AD2066L-G
GPRS IP MODEM
AD2066L-C
CDMA IP MODEM
AD2066L-W
WCDMA IP MODEM
AD2066L-E
EVDO IP MODEM
AD2066L-F
FDD-LTE IP MODEM
AD2066L-D
TDD/FDD-LTE IP MODEM
AD2066L-GP
GPS+GPRS IP MODEM
AD2066L-CP
GPS+CDMA IP MODEM
AD2066L-WP
GPS+WCDMA IP MODEM
AD2066L-EP
GPS+EVDO IP MODEM
AD2066L-FP
GPS+FDD-LTE IP MODEM
Standard
AD2066L-DP
GPS+TDD/FDD-LTE IP MODEM

AD2066L IP Mode
m User Manual
Web:en.alotcer.com Add:NO.146-148, 2nd XingBei Road, JiMei District, XiaMen, China.
Contents
Contents
Chapter 1 Brief Introduction of Product ......................................................................................4
1.1 General .............................................................................................................................4
1.2 Product Feature ...............................................................................................................4
1.3 Block Diagram..................................................................................................................5
1.4 Product Spec....................................................................................................................6
1.5 Ordering Information .......................................................................................................8
Chapter 2 Installation Introduction...............................................................................................9
2.1 General .............................................................................................................................9
2.2 Encasement List ..............................................................................................................9
2.3 Installation and Cable Connection ................................................................................9
2.4 Power ..............................................................................................................................13
2.5 Indicator Lights Introduction.........................................................................................14
Chapter 3 Configuration..............................................................................................................15
3.1 Configuration Connection.............................................................................................15
3.2 Configuration Introduction ............................................................................................15
3.2.1 Control Command ..............................................................................................18
3.2.2 Configuration command ................................................................................21
3.2.3 Status command ..............................................................................................23
3.3 Express Configuration ..................................................................................................26
3.4 Parameter configuration............................................................................................27
3.4.1 Central configuration ......................................................................................27
3.4.2 Basic parameters .............................................................................................32
3.4.3 Advanced parameter .......................................................................................40
3.4.4 SMS......................................................................................................................45
3.4.5 IO configuration
....................................................................................................47
3.4.6 Locate the configuration....................................................................................47
3.4.7 Other configuration.............................................................................................51
3.5 Working state switch .....................................................................................................53
3.5.1 Communication Mode........................................................................................53
3.5.2 Upgrade Mode ....................................................................................................53
Chapter 4 BOOT Operation Command ..............................................................................54
4.1 Operation Command ..................................................................................................54

AD2066L IP Mode
m User Manual
Web:en.alotcer.com Add:NO.146-148, 2nd XingBei Road, JiMei District, XiaMen, China.
Chapter 1 Brief Introduction of Product
1.1 General
AD2066L IP MODEM is a kind of cellular terminal device that developed based on
2G/3G/4G technology.It adopts high-powered industrial 32 bits CPU and embedded real
time operating system. It supports RS232 and RS485 (or RS422) port that can
conveniently and transparently connect one device to a cellular network, allowing you to
connect to your existing serial devices with only basic configuration. It has compatible
digital I/O channel, ADC and pulse wave output function. It adopts low-power
consumption design, operating current <8mA (@12VDC) in sleep state, intelligent sleep
control, and still maintains link in sleep state, ensuring stable transmission and no data
loss, meeting the needs of industrial field communication.
It has been widely used on M2M fields, such as intelligent transportation, smart grid,
industrial automation, telemetry, finance, POS, water supply, environment protection,
post, weather, and so on.
IP MODEM Application Topology
1.2 Product Feature
Items
Contents
High-powered industrial cellular module
High-powered industrial 32bits CPU
Industrial
Design
Low power consumption design, support multi-sleep and trigger

AD2066L IP Mode
m User Manual
Web:en.alotcer.com Add:NO.146-148, 2nd XingBei Road, JiMei District, XiaMen, China.
modes
Housing: iron, providing IP30 protection
Power range: DC 5~35V
Support hardware and software WDT
Support auto recovery mechanism, including online detect, auto
redial when offline to make it always online
RS232/RS485/RS422 ports:15KV ESD protection
SIM/UIM port: 15KV ESD protection
Power port: reverse-voltage and overvoltage protection
High
Reliability
Antenna port: lightning protection(optional)
Adopt terminal block interface, convenient for industrial application
Support standard RS232/RS485 ports that can connect to serial
devices directly
Two RS232 interfaces
TTL logic level UART interface can be customized
Support intellectual mode, enter into communication state
automatically when powered
Support several work modes
Standard and
Convenience
Convenient configuration and maintenance interface
Support TCP server, it can support 4 TCP connections at the same
time
Support double data centers, one main and another backup
and multi data centers synchronous transmission(5 data centers)
Support multi online trigger ways, including SMS, ring and data.
Support link disconnection when timeout
Supply 2 I/O channels, compatible 2 ADC inputs, 2 OC inputs、2
OC outputs(drive capability 20mA)
Support dynamic domain name(DDNS) and IP access to data
center
Design with standard TCP/IP protocol stack
Support APN/VPDN
High-
performance
and Security
Support TCP server, it can support 4 TCP connections at the same
time
1.3 Block Diagram

AD2066L IP Mode
m User Manual
Web:en.alotcer.com Add:NO.146-148, 2nd XingBei Road, JiMei District, XiaMen, China.
1.4 Product Spec
Items
Contents
CPU
Industrial 32 bits CPU
FLASH
4MB
Hardware
System
SDRAM
256KB(Extendable to 1MB)
Serial
2 RS232 port and 1 RS485(or RS422) port, 15KV ESD
protection
Data bits: 5, 6 ,7, 8
Stop bits: 1, 1.5(optional), 2
Parity: none, even, odd, space, mark
Baud rate: 1200~256000bits/s
Antenna
Cellular: Standard SMA female interface, 50 ohm
GPS(optional):Standard SMA female interface, 50 ohm
SIM/UIM
Standard 3V/1.8V user card interface, 15KV ESD
protection
Power
Terminal block interface, reverse-voltage and
overvoltage protection
Interface
Indicator
“PWR”、”RUN”、”Online”、”GPS”(optional)

AD2066L IP Mode
m User Manual
Web:en.alotcer.com Add:NO.146-148, 2nd XingBei Road, JiMei District, XiaMen, China.
Wireless
Network
GSM/GPRS/EDGE: 850/900/1800/1900MHz
CDMA: 800/1900MHz
WCDMA/HSUPA/HSPA+: 850/900/1900/2100MHz
CDMA2000 1x/ EVDO Rev. A: 800/1900MHz
TD-SCDMA: 1880-1920/2010-2025MHz(A/F)
TDD-LTE: Band 38/39/40/41& Band 61/62
FDD-LTE: Band 1/2/3/4/5/7/8/13/17/20/25/28
PPP Protocol
Support PPP Protocol
PPP Heartbeat
Maintaining links with the cellular network to prevent
forced sleep, to ensure the stability of dial-up link.
Network
Authentication
Support CHAP/PAP Authentication
Network
TCP Heartbeat
Monitor the server connection
Receiver Type
50-channle
GPS L1(1575.42MHz)C/A code
SBAS: WAAS,EGNOS,MSAS,GAGAN
Max. update
rate
5 Hz
Accuracy
Position: 2.5m CPE
SBAS: 2.0m CPE
Acquisition
Cold starts: 29S
Warm starts: 29S
Aided starts: <1S
Hot starts: <1S
Sensitivity
Tracking: -160dBm
Reacquisition: -160dBm
Cold starts: -146dBm
Timing accuracy
RMS: 30ns
99%: <60ns
Granularity: 21ns
GPS
(optional)
Time pulse
Configurable, 0.25 to 1000Hz
Standard Power
DC 12V/1.5A
Power range
DC 5~35V
Communication
Current
<100mA (@12VDC)
Power
supply
Sleep current
<8mA(@12VDC)
Dimensions
91x59x23mm
Physical
Weight
175g
Environme
Operating
-35~+75ºC(-31~+167℉)

AD2066L IP Mode
m User Manual
Web:en.alotcer.com Add:NO.146-148, 2nd XingBei Road, JiMei District, XiaMen, China.
1.5 Ordering Information
Choice
Model
Network
Optional
AD2066L
-G: GPRS
-C: CDMA
-W: WCDMA
-E: EVDO
-F: FDD-LTE
-D: TDD/FDD-LTE
P: GPS
B: BeiDou
Example
AD2066L-GP: AD2066L GPRS IP MODEM
Temperature
Storage
Temperature
-40~+85ºC (-40~+185℉)
ntal Limits
Operating
Humidity
95% ( unfreezing)

AD2066L IP Mode
m User Manual
Web:en.alotcer.com Add:NO.146-148, 2nd XingBei Road, JiMei District, XiaMen, China.
Chapter 2 Installation Introduction
2.1 General
The IP MODEM should be installed correctly to make it work properly.
Warning: Forbid to install the IP MODEM when powered!
2.2 Encasement List
Please take care of you when opening the packing material for future use.
Name
Quantity
Remark
IP MODEM host
1
Cellular Antenna(SMA)
1
Power adapter
1
RS232 data cable
1
RS485 data cable
1
Optional
Certification card
1
GPS Antenna(SMA)
1
Optional
2.3 Installation and Cable Connection
Dimension (The fixing piece is detachable): (Unit:mm)、

AD2066L IP Mode
m User Manual
Web:en.alotcer.com Add:NO.146-148, 2nd XingBei Road, JiMei District, XiaMen, China.
Installation of antenna:
Cellular antenna (Standard) GPS antenna (Optional)
Screw the SMA male pin of the cellular antenna to the female SMA interface of the
modem with sign “ANT”.
Screw the SMA male pin of the GPS antenna to the female SMA interface of the modem
with sign “GPS”.
Warning: The cellular antenna and the GPS antenna can not be connected wrongly. And
the antennas must be screwed tightly, or the signal quality of antenna will be influenced!
Installation of SIM/UIM card:
Installation of SIM/UIM card
Firstly power off the modem, and press the out button of the SIM/UIM card out with a
needle object. Then the SIM/UIM card sheath will flick out at once. Put SIM/UIM card into
the card sheath (Pay attention to put the side which has metal point outside), and insert
card sheath back to the SIM/UIM card outlet.
Warning: Forbid to install SIM/UIM card when powered!
User Interface Signal Definition

AD2066L IP Mode
m User Manual
Web:en.alotcer.com Add:NO.146-148, 2nd XingBei Road, JiMei District, XiaMen, China.
Installation of cable:
Pin
Number
Signal
Name
Default
Function
Extensible Function
1
PWR
Power input
anode
N/A
2
PG
Power Ground
N/A
3
RX1
RS232 RX 1
N/A
4
TX1
RS232 TX 1
N/A
5
GND
Power Ground
N/A
6
A
RS485 anode
RS422 R+/RS485 A
7
B
RS485 cathode
RS422 R-/RS485 B
8
GND
Power Ground
GPIO,dry contact signal and 3.3V
switch quantity signal detecting , 3.3V
switching signal output /ADC, analog
acquisition
9
RX2
RS232 RX 2
RS422 T-/TTL serial port
receives/GPIO, dry contact signal and
3.3V switch quantity signal detecting ,
3.3V switching signal output /ADC,
analog acquisition
10
TX2
RS232 TX 2
RS422 T+/TTL serial
transmission/GPIO,dry contact signal
and 3.3V switch quantity signal
detecting ,3.3V switching signal output
/ADC, analog acquisition
11
IO1
GPIO
dry contact signal and 3.3V switch
quantity signal detecting,3.3V
switching signal output /ADC, analog
acquisition
12
IO2
ADC,Analog
acquisition
GPIO, dry contact signal and 3.3V
switch quantity signal detecting , 3.3V
switching signal output /ADC, analog
acquisition

AD2066L IP Mode
m User Manual
Web:en.alotcer.com Add:NO.146-148, 2nd XingBei Road, JiMei District, XiaMen, China.
RS232 cable(standard)RS485 cable(optional)
Ip Modem adopts industrial terminal block interface. Recommend cable is 28-16AWG.
The detail description of standard layout adapter and communication cables as is
following.
Adapter(Rating Output 12VDC/0.5A):
Cable Color
Power Output Polarity
Black &White Alternate
Anode
Black
Cathode
RS232 Cable(One end is DB9 Female header):
Cable Color
Corresponding DB9-M Pin Number
Blue
Pin 2
Brown
Pin 3
Black
Pin 5
RS485 Cable(Optional):
Cable Color
Signal definition
Red
RS485(A)
Black
RS485(B)
Power adapter and communication cable connection chart as following:

AD2066L IP Mode
m User Manual
Web:en.alotcer.com Add:NO.146-148, 2nd XingBei Road, JiMei District, XiaMen, China.
(ripple less than 300mV, and the instantaneous voltage does not exceed 35V), and the
power supply is above 4W.
We recommend user to use the standard DC 12V/0.5A power adaptor.
2.5 Indicator Lights Introduction
There are three indicator lights: “Power”, “RUN”, “Online”,”GPS”(Optional).
Indicator Light
State
Introduction
ON
IP MODEM is powered on
Power
OFF
IP MODEM is powered off
BLINK
IP MODEM works properly
RUN
OFF
IP MODEM does not work
ON
IP MODEM has logged on network
Online
OFF
IP MODEM hasn’t logged on network
ON
Effective GPS
GPS
OFF
No Effective GPS

AD2066L IP Mode
m User Manual
Web:en.alotcer.com Add:NO.146-148, 2nd XingBei Road, JiMei District, XiaMen, China.
Chapter 3 Configuration
3.1 Configuration Connection
Before configuration, please connect the IP MODEM with the configure PC by the
supplied RS232 or RS232-485 conversion cable as following.
3.2 Configuration Introduction
There are two ways to configure the IP MODEM:
Configuration software tool: All the settings are configured by the configure tool
running on PC.

AD2066L IP Mode
m User Manual
Web:en.alotcer.com Add:NO.146-148, 2nd XingBei Road, JiMei District, XiaMen, China.
After the device is connected to the computer,Run the configuration tool to select the
corresponding COM,Select 115200 baud calibration and check bit as N(Other Settings
invalid),Click on the open button. A prompt message will be given in the output message
bar: Wait for the device to be powered on and enter the config mode...
Please repower the equipment at this time.

AD2066L IP Mode
m User Manual
Web:en.alotcer.com Add:NO.146-148, 2nd XingBei Road, JiMei District, XiaMen, China.
When the device is powered on, the current configuration parameters in the device
are automatically loaded and displayed in the information output box on the left,At this
point, you can configure the parameters.
Extended AT command: In this configuration, the user only need to have a serial
communication program can configure all the parameters of the digital terminal, such as
WINDOWS HyperTerminal, LINUX minicom, putty, etc., or directly by the user's micro
controller system on the device.
Note: Before configuration with extended AT command, you should make IP
MODEM enter configure state.
Each extended AT command should end with a carriage return. Commands are
divided into three categories: configuration command, control command and status
command. The return values of commands fall into the following categories:
OK Successful command configuration
ERROR Command configuration failed
UNMATCH No matches
UNSUPPORT This command is not supported
LEN OVERFLOW The configuration value exceeds the maximum range

AD2066L IP Mode
m User Manual
Web:en.alotcer.com Add:NO.146-148, 2nd XingBei Road, JiMei District, XiaMen, China.
OUTOFF RANGE Configuration values are not within the prescribed range
UNKNOWN Unknown instructions
3.2.1 Control Command
Control Command:Used for users to perform some operations on devices.
Control command query instruction:The AT+SHOWCOMMAND command allows
the user to see which operating commands are currently in the device. The following are
some of the keywords that users can manipulate:
SHOWCONFIG (Show all configurations)
SHOWCOMMAND (Display actionable control keywords)
STATUS (Get system status)
COMMIT (Save configuration)
DEFAULT (Reset)
REBOOT (Cold start)
HBOOT (Hot Start)
SYSTIME (Get system time)
...
Note: Control keywords not listed are indicated by ....
The AT command of the control instruction is:
AT+XXX XXX Represents the keyword to manipulate the instruction, for
example to display all configurations, the instruction is at+showconfig
Remark: The AT command format is the basic control command operation format.
The following is the detailed introduction and operation of the control command.:
3.2.1.1 Display all current configurations:
Ability to display how many configuration items are available for the device.
AT+SHOWCONFIG

AD2066L IP Mode
m User Manual
Web:en.alotcer.com Add:NO.146-148, 2nd XingBei Road, JiMei District, XiaMen, China.
3.2.1.2 Shows how many control commands are currently available:
which control commands are available for display devices.
AT+SHOWCOMMAND
3.2.1.3 Save configuration:
This instruction is used to save the configuration when the configuration is set.
AT+COMMIT
3.2.1.4 Factory reset:
Ability to restore device configuration to factory configuration.
AT+DEFAULT
3.2.1.5 Cold start:
Restart the DTU device after power-on and re-detect the hardware.
AT+REBOOT
3.2.1.6 System time:
View System time: view time:
AT+SYSTIME or AT+SYSTIME=?
Configure system time: If you need to change the system time of the DTU, you can
use this command to configure.
AT+SYSTIME=xxxx
Where xxx is the time to be set, and the time format is aaaabbccddeeff
aaaa is year, bb is month, cc is day, dd is hour, ee is minute,and ff is second.
For example, to configure the system time as 2019/2/23/9/9/5
AT+SYSTIME=20190223090905
This manual suits for next models
12
Table of contents
Other Alotcer Modem manuals