6
DOOR 1
(Network address 01)
DOOR 4
(Network address 04)
DOOR 2
(Network address 02)
DOOR 3
(Network address 03)
(LAST DOOR)
+NO C NC 4 5 6 7 8 9-
D2
EXIT
BUTTON
COAX
PROX
RS
PROX
COAX
PROX
RS
PROX
COAX
PROX
RS
PROX
COAX
PROX
RS
PROX
LOCK OUTPUT
RELAY
12VDC
EVE196-X3-RS CONTROL UNIT
Class E (CAT6) U/UTP
1 2
+ -
+NO C NC 4 5 6 7 8 9-
D2
EXIT
BUTTON
LOCK OUTPUT
RELAY
12VDC
EVE196-X3-RS CONTROL UNIT
Class E (CAT6) U/UTP
1 2
+ -
+NO C NC 4 5 6 7 8 9-
D2
EXIT
BUTTON
LOCK OUTPUT
RELAY
12VDC
EVE196-X3-RS CONTROL UNIT
Class E (CAT6) U/UTP
Fit a 120Ω (OHM) resistor
1 2
+ -
+NO C NC 4 5 6 7 8 9-
D2
EXIT
BUTTON
120Ω
LOCK OUTPUT
RELAY
12VDC
EVE196-X3-RS CONTROL UNIT
1 2
+ -
Class E (CAT6) U/UTP
IGSMDATA4
SIM card
pre-installed
Internal aerial (already tted).
Replace with ZAN1055 external aerial
to get the best signal available.
D2 of IGSMDATA4 & IGSMDATA32
+-
12V
+-
D2
Door 1, Door 2, Door 7
etc. Trained installers
equipped with TELU
programmer can program
default EVE196-X3-RS
door setting themselves. All
actual system operational
programming is via www.
baticonnect.com
Each individual EVE196-X3-RS
control unit can be remotely
triggered by calling the IGSMDATA
modem from a registered phone
number on www.baticonnect.com.
Maximum 10 doors on IGSMDATA32 Modem.
Additional doors can be added by creating
additional networks in conjunction with more
IGSM data modems.
IGSMDATA4 / 32 DATA MODEM
Networking doors onto IGSMDATA modem
At the end of the bus chain / network, YOU MUST add resistance
either by switching on RT2 on the last EVE only or by adding a
120 (OHM) resistor, as shown above.