Configure:
System will be Configured with default settings. To change those settings press the “Config” button on the switch panel screen.
Brightness –Sets screen brightness
Sleep –Turns screen off, will not change settings. Press anywhere on screen to turn
back on.
Select Channel- Press to see list of available channels, then select channel to modify
Not all features are available for all circuits.
Channel –Displays channel name. Aux1 and Aux 2 are modifiable.
Max Current: Select maximum fused amperage for circuit (0-30amps).
Soft Start: Check box to allow slow increase in current at turn on.
Limit Enabled: Check box to limit circuit turn on by temperature settings
(Fan or Water Only)
Temperature: Select temperature to enable.
Hysteresis: Differential temperature change required to activate.
(Ex: With a 2º hysteresis and a 100º temperature setting the controller will allow
the actual temperature to go to 98º before turning off Fan and Pump and back to
100º to turn on again) allow the actual temperature to go to 98º before turning off Fan and Pump and back to 100º to turn on again)
Auto Switch: Check box to enable. Allows circuit to automatically
Enable after a set delay time, once Start button is
pressed. Also allows circuit to Disable when Ignition
button is turned off.
Auto Switch Delay: Time in seconds circuit is delayed from turning
on after Start button is pressed.
Save: Saves changes and returns to previous Menu.