Altronics FOTEK NT-RV Series User manual

■Specification / Especificaciones:
Type
DIN 48*48
DIN 72*72 /48*96 /96*96
DIN 24*48
Model
NT-48RV-AF
NT-XX-RV-AF
NT-10-AF
Output method
Relay & SSR
Relay or SSR
Rated current
Relay (5A/250VAC);SSR(30mA/12V)
Operating voltage
90~265VAC 50/60Hz
Alarm output
Relay (5A/250VAC)
Control method
PID + Fuzzy
Input method
PT / K / J / R / S / T/ B / E / N / L Selectable
Display range
-999 ~ 9999 或-99.9 ~ 999.9 Selectable
Accuracy of display
± ( 0.1 % of F.S. + 1 DIGIT)
Setting range
-999 ~ 9999 或-99.9 ~ 999.9 Selectable
Dielectric strength
Over 2.5KV
Isolation strength
Over 100MΩ / 500VDC
Operating temp
﹣20℃~ ﹢80℃;35 ~ 85%RH
Housing material
Intensive PC+ABS(UL-94V0)
■Mode of alarm / Modos de Alarma
ALt
Description / Descripción
ALt
Description / Descripción
ALt
Description / Descripción
0
AL1 ON
SV (SV+AL1)
AL2 ON
SV (SV+AL2)
1
AL1 ON
(SV - AL1) SV
AL2 ON
SV (SV+AL2)
2
AL1 ON
(SV - AL1) SV
AL2 ON
(SV –AL2) SV
3
AL1 ON
(SV –AL2) SV (SV+AL1)
AL2 ON
SV (SV+AL2)
4
AL1 ON
(SV –AL1) SV (SV+AL1)
AL2 ON
SV (SV+AL2)
5
AL1 ON
(SV - AL1) SV (SV+AL1)
AL2 ON
SV (SV+AL2)
6
AL1 ON
AL1
AL2 ON
AL2
7
AL1 ON First cycle unable
AL1
AL2 ON
AL2
8
AL1 ON First cycle unable
(SV - AL1) SV
AL2 ON
SV (SV+AL2)
9
AL1 ON First cycle unable
(SV - AL1) SV (SV+AL1)
AL2 ON
SV (SV+AL2)
10
AL1 ON
SV (SV+AL1)
AL2 ON
SV tnr 99h59m
11
AL1 ON
AL1
AL2 ON
AL2
12
AL1 ON
AL1
AL2 ON
AL2
13
AL1 ON
SV (SV+AL1)
AL2 ON
(SV –AL2) SV
14
AL1 ON
SV (SV+AL1)
AL2 ON
(SV –AL2) SV
15
AL1 ON 1 Flicker
SV (SV+AL1)
AL2 ON
SV (SV+AL2)
16
AL1 ON
SV (SV+AL1)
AL2 ON
SV tnr 99h59m
17
AL1 ON
SV (SV+AL1)
AL2 ON
SV tnr 99m59s
18
AL1 ON
SV (SV+AL1)
AL2 ON
SV tnr 99m59s
19
Non-used
20
AL1 ON 1 Flicker
SV (SV+AL1)
AL2 ON
SV (SV+AL2)
21
AL1 ON 1 Flicker
SV (SV+AL1)
AL2 ON First cycle unable
(SV - AL1) SV (SV+AL2)
22
AL1 ON 1 Flicker
SV (SV+AL1)
AL2 ON
(SV - AL1) SV
23
AL1 ON 1 Flicker
SV (SV+AL1)
AL2 ON
(SV - AL1) SV
24
AL1 ON 1 Flicker
SV (SV+AL1)
AL2 ON
(SV - AL1) SV (SV+AL2)
25
AL1 ON 1 Flicker
SV (SV+AL1)
AL2 ON
(SV - AL1) SV (SV+AL2)
26
AL1 ON
AL1 SV
AL2 ON First cycle unable
(SV –AL2) SV
1.「ALt=15」: t = ON time of AL2 for cooling, OFF time is controlled by PID.
2.「ALH」:Hysteresis of alarm. Ex. PV≧(SV+AL1)→AL1 ON, PV<(SV+AL1-ALH)→AL1 OFF
3.「tnu」= Process time of tnr, if「tnu≧tnr」→ AL2 is turned ON or OFF
UL CE
RoHs
Instruction Manual / Manual de Uso
F - 71
NT-XX-RV-AF series All function temperature controller
Thank you very much for using FOTEK NT-XX-RV series All function Temperature controller
Please read this instruction manual before operating it to avoid from the malfunction.
FOTEK NT10-R-AF / NT-22-R-AF / NT-48RV / NT-72-RV / NT-20-RV / NT-21-RV / NT96-RV-AF
AlltronicsPerú
AUTOMATIZACIÓN INDUSTRIAL
https://www.fotek.com.tw
https://alltronicsperu.com

■Procedure of operating / Procedimiento de operación
1. Setting of heating timer / Ajuste de temporizador:Press SET key
Control status Temp setting Heating time setting Control status
8 8 8 8
Press SET key
8 8 8 8
Press SET key
tn r
Press SET key
8 8 8 8
8 8 8 8
8 8 8 8
99.59
8 8 8 8
1-1. After the time of heating being finished , The display of SV will display the「Temp setting value」& 「OFF」,
Meanwhile the temp control output will be Turned off and the AL1 output will be turned on.
1-2. It will be reset by setting the OFF/▼ key or turning off the power of controller If the time of heating being finished.
1-3. If「Fun=SoF」or「Fun=noF」, setting of heating time will be unable.
2. Selecting of display / Seleccion de pantalla:Press SET key 3 seconds【「Fun=SoF」or「Fun=noF」without selecting】
Control status Control status Control status
8 8 8 8
Press SET key
8 8 8 8
Press SET key
8 8 8 8
8 8 8 8
3 seconds
99.59
3 seconds
8 8 8 8
2-1. Press SET key to change the 「temp setting value」or「heating time」on SV display.
3. Soft start:rAp Unit:Arranque Suave: Unidad de Rampa : ℃/ Minute / °C / Minuto
Control status Rising speed Control status
8 8 8 8
Press SET key
r A p
Press SET key
8 8 8 8
8 8 8 8
3 seconds
0
3 seconds
8 8 8 8
1-1. Press SET key 3 seconds into「Soft start」setting status;if 「rAp」= 0, it don’t to do Soft start
1-2.「rAp」setting range:0 ~ 9999 or 0.0~999.9
1-3.「rAp」> 0;Power on or ON/FF or to change setting value or stand-by change to normal control, it will work by Soft start
※Release Soft start:In soft start status, Press SET key 3 seconds may to release Soft start status.
4. Manual control / Control modo Manual:Press OFF/▼+ stb/▲ key 3 seconds
Control status Manual volume Control status
8 8 8 8
Press OFF/▼+ stb/▲ key
8 8 8 8
Press OFF/▼ key
6 6 6 6
8 8 8 8
3 seconds
n. xx
3 seconds
6 6 6 6
※Press OFF/▼+ stb/▲ key 3 seconds into manual control volume setting status
→ SV will display「n.000」that may to set the manual control volume.
※Release manual control:In the manual control, Press OFF/▼ key 3 seconds to return the control status.
5. OFF(Stop)Función Stop: Press OFF/▼ key 3 seconds
Control status OFF status Control status
8 8 8 8
Press OFF/▼ key
8 8 8 8
Press OFF/▼ key
8 8 8 8
8 8 8 8
3 seconds
O F F
3 seconds
8 8 8 8
※Press OFF/▼ key 3 seconds → SV displays 「OFF」into the stop control status.
※Release OFF status:In the stop control status, Press OFF/▼ key 3 seconds may to turn the status to control status.
6. AT(Auto-tuning): Press AT/<< key 3 seconds into the auto-tuning status, pilot「AT」on.
In the auto-tuning status, Press AT/<< key 3 seconds may return to control status.
7. Parameter Setting:Press SET & ▼key 3 seconds
8. Alarm setting:Press SET & AT/<< key 3 seconds
https://www.fotek.com.tw
https://alltronicsperu.com

■Setting of alarm
Function
Display
Range
Description
Control status
控溫狀態
Press &key 3 sec
Lock setting
鎖定設定
Press SET
AL1 Limit setting
AL1 警報設定
Press SET
Hysteresis of alarm
警報應差值設定
Press SET
Delay time of alarm on
警報動作延遲時間設定
Press SET
Setting limit
最大設定值限制
Press SET
Output limit
輸出量限制設定
Press SET
Process output volume
實際輸出量
Press SET
Min. output volume setting
最小輸出量設定
Press SET
8 8 8 8
8888
L c k
0
A L 1
2 0
A L H
1
o n d
1200
S L h
4 0 0
O u t
1 0 0
U n
0 . 0
Lot
0
-999 ~ 9999
0 ~ 3
-999 ~ 9999
-999 ~ 9999
0 ~ 9999
0 ~ 9999
0 ~ 100%
0 ~ 100%
0 ~ 100%
1>「Lck=0」: Unlock;「 Lck=1」: SV settable only
2>「Lck=2」: SV&AL settable;「 Lck=3」: All lock
Refer to alarm mode
Hysteresis of alarm
1> Unit:Second
2> For alarm mode #2 (Alt.2)
1> SV≦SLH
1> Limit of output volume
2> Output volume = Control output volume *「Out」
1> Display of output volume
1> Output volume=「Lot」+ control volume
■Outline & Connecting diagram
NT-48RV
NT-72RV
NT-10
https://www.fotek.com.tw
https://alltronicsperu.com

■Setting of parameter / 參數設定
Function
Range
Description
Control status
8888
控制狀態
8888
Press &key 3 sec
Output method
con
輸出方式
r
Press SET key
Cycle time
C t
動作週期
15
Press SET key
Auto tuning
A t
自動演算
0
Press SET key
Proportion band
P
比例帶
36
Press SET key
Integral time
I
積分時間
120
Press SET key
Derivative time
d
微分時間
30
Press SET key
Hysteresis
H Y S
動作應差
1
Press SET key
Input selecting
I n t
輸入選擇
k
Press SET key
Unit selecting
U n t
單位選擇
C
Press SET key
Decimal point selecting
d p
小數點選擇
0
Press SET key
Input shift setting
S H t
輸入修正
0
Press SET key
Input span setting
Spn
輸入斜率修正
1.000
Press SET key
Alarm mode setting
A L t
警報模式設定
0
Press SET key
Function selection
Fun
功能選擇選擇
noF
Press SET key
Timing mode selection
t n d
計時模式選擇
0
Press SET key
Timing unit selection
t u t
時間單位選擇
nS
Press SET key
-200 ~ 9999
r or S
0 ~ 1
0 ~ 99
0 ~ 3999
0 ~ 3999
0 ~ 3999
0 ~ 99
PT / K / J / R / S
T / B / E / N / L
℃/ ℉
0 ~ 1
- 99 ~ + 99
0.001~9.999
0 ~ 26
ALL/tnr/SoF/ noF
0 or 1
nS or hr
1>「con = r」: Relay output
2>「con = S」: SSR output
1>「Ct = 0」: ON/OFF control
2> Range:0~99s(con = r)or 0.0~9.9s(con = S)
1>「At = 0」: Control status
2>「At = 1」: Auto tuning status
1>「Ct = 0」→ 「P」is disappeared
1>「Ct = 0」→ 「I」is disappeared
1>「Ct = 0」→「d」is disappeared
1>「Ct = 0」→ 「Hys」is appeared only
2>(PV>SV)→ Out ON;
〔PV<(SV-Hys)〕→ Out OFF
1> 10 input type are selectable
1>「d p = 0」: Without decimal point
2>「d p = 1」: One decimal point
1>「PV」=(PV + Sht)
1>「PV」=(PV * Spn)
1> Refer to the mode of Alarm
1.「Fun=ALL」: with heating timer and soft start function
2.「Fun=tnr」: with heating timer only
3.「Fun=SoF」: with soft start function only
4.「Fun=noF」: without heating timer and soft start function
1>「0」: PV≧SV to start timing
2>「1」: Power on to start timing
1>「nS」: 0~99m59s
2>「hr」: 0~99h59m
Copy right @FOTEK CONTROLS CO., LTD. 2016/1/10
Specification may be modified without notice in advance
規格變更恕不事先通知
FOTEK CONTROLS CO., LTD.
This manual suits for next models
7
Table of contents
Other Altronics Controllers manuals