Altronix Trove T2RM7F8SQ User manual

T2RM7F8SQ
8 Door Kit with Fused Outputs
Fully assembled kit includes:
- Trove2R enclosure with TM2R Altronix/Mercury backplane
- One (1) eFlow104NB - Power Supply/Charger
- One (1) LINQ8ACM - Dual Input Networked Fused
Access Power Controller
- One (1) VR6 - Voltage Regulator
- One (1) PDS8 - Dual Input Fused Power Distribution Module
T2RM7F8SDQ
8 Door Kit with PTC Outputs
Fully assembled kit includes:
- Trove2R enclosure with TM2R Altronix/Mercury backplane
- One (1) eFlow104NB - Power Supply/Charger
- One (1) LINQ8ACMCB - Dual Input Networked PTC
Access Power Controller
- One (1) VR6 - Voltage Regulator
- One (1) PDS8CB - Dual Input PTC Power Distribution Module
Altronix/Mercury Networked Rack Kits
Models Include:
Rev. 060823
Installing Company: _________________________ Service Rep. Name: __________________________________________
Address: _________________________________________________________ Phone #: _________________________
All registered trademarks are property of their respective owners. More than just power.™
Installation Guide
All components of these Trove kits are UL Listed sub-assemblies.
Please refer to the included corresponding Sub-Assembly Installation Guides for further information.
Access & Power Integration

- 2 - T2RM7F8S(D)Q Installation Guide
Overview:
Altronix Trove Mercury rack kits are pre-assembled and consist of Trove enclosures/backplanes with factory installed Altronix power supply/charger
and sub-assemblies. All kits accommodate a variety of Mercury modules for up to eight doors in a single enclosure.
Configuration Chart:
Altronix
Model
Number
120VAC 60Hz
Input Current (A)
Power Supply Board
Input Fuse Rating
Power Supply Board
Battery Fuse Rating
Nominal DC
Output Voltage
Maximum Supply
Current for Main
and Aux. Outputs on
Power Supply board
and LINQ8ACM(CB)
Access Power
Controller’s outputs
Fail-Safe/Fail-Secure or
Dry Form “C” Outputs
Current Per LINQ8ACM(CB)
Output (A)
LINQ8ACM(CB) Board
Input Fuse (PTC) Rating
LINQ8ACM(CB) Board
Output Fuse (PTC) Rating
PDS8(CB) Board
Input Fuse (PTC) Rating
PDS8(CB) Board
Output Fuse (PTC) Rating
[DC] [Aux]
Output
Range
(VDC)
Output
Range
(VDC)
T2RM7F8SQ
4.5 6.3A/
250V
15A/
32V
20.17-
26.4
20.28-
26.4 24VDC @ 9.2A 8
2.5 15A/
32V
3A/
32V
10A/
32V
3A/
32V
T2RM7F8SDQ 2.0 9A 2.5A 9A 2.5A
Hardware:
Spacer | 5/16” Pan Head Screw | Lock Nut
Installing Trove2R into Rack Tower:
Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI, and with all local codes and authorities having jurisdiction.
These products are for indoor use only and must be installed within the protected premises.
Note: First assemble and Install Z Bracket Wire Management Accesory (refer to Z Bracket Installation pg. 3)
1. Remove backplane from enclosure prior to installing into rack cabinet (do not discard hardware).
2. In order to mount included cUL Listed tamper switch (Tane Model 3/8 ASH FM WH or equivalent),
turn the enclosure upside down and locate mounting holes (Fig. 1, pg. 2).
Insert the tamper switch flying leads into the center knockout of the three (3) holes from outside of the
drawer with the button facing outwards, make sure tamper switch is inserted properly then secure it
with the two (2) screws (supplied). Connect tamper switch wiring to the Access Control Panel input or
the appropriate UL Listed reporting device. To activate alarm signal open the rack drawer.
3. Slide the rack enclosure into an open 2U location in the four post rack cabinet.
4. Utilizing proper fasteners attach front ears to the rack rails (Rack drawer, pg. 8).
5. Attach the rear of the adjustable slides to the rear rails of the rack cabinet with the proper fasteners.
6. Secure the rack cover (Fig. 2a, pg. 3) and rack drawer (Fig. 2b, pg. 3) to earth ground.
7. Ensure that all internal cofigurations (voltage selection, switch settings, etc.) are completed before
mounting backplane back into Trove rack enclosure.
Fig. 1
Back of the drawer,
viewed from outside.
Tamper Switch
mounting location
Fig. 2
Fig. 2a
Fig. 2b

T2RM7F8S(D)Q Installation Guide - 3 -
Z Bracket Installation for Trove2R:
Altronix Trove2R enclosure includes Z Bracket, a convenient and reliable wire management accessory.
Hardware (included):
Twelve (12) bolts and eight (8) lock nuts.
1. Carefully unpack Z Bracket. Do not discard included hardware
(Fig. 3, pg. 3).
2. Attach arms to each other using bolts and lock nuts (Fig. 4a, pg. 3).
3. Attach the hinge brackets to the ends of arms using bolts and nuts,
positioning them as shown on (Fig. 4b, pg. 3).
4. Make sure that all nuts are tightened.
5. Attach the hinge bracket on each end of Z Bracket, then attache the Z Bracket to the adjustable slide using bolts and lock nuts
(included) (Fig. 5, 5a, pg. 3).
6. Attach the hinge bracket on the shorter side of Z Bracket to the rear of the rack enclosure using bolts (included).
Fig. 5
Fig. 5a
Fig. 4b
Fig. 3
Fig. 4a
Fig. 4
Fig. 3b

- 4 - T2RM7F8S(D)Q Installation Guide
T2RM7F8S(D)Q: Configuration of Mercury Boards:
1. Fasten spacers onto metal pems configuration
(A), (B) or (C) of backplane depending on the
access controller (Fig. 6, pg. 4).
2. Position access controller module over corresponding
spacers and fasten screws into spacers (Fig. 6a, pg. 4).
3. Mount backplane to enclosure with hardware.
Mercury Access Controller
Position Chart for the
Following Models:
Altronix/Mercury Pem Mounting
LP1502, LP4502, MR52,
MR16IN, MR16OUT A
LP2500, MUX8 B
Genetec Cloudlink C
B
C
Altronix
eFlow104NB
– DC +– BAT +
L G N
Altronix VR6
is mounted
under
LINQ8ACM(CB)
+ INP1 --
PWR1 +OFF
IN1
IN2
PWR1 +
PWR2 +
PWR2 +
COM (--- )
COM (--- )
+ INP2 --
IN1 Fuse
Common Power Outputs (NEG)
N
P
OUT1 OUT2 OUT3 OUT4 OUT5 OUT6 OUT7 OUT8
1 2 3 4 5 6 7 8
Altronix PDS8(CB)
A
AA
A
COM -
+PWR2 +PWR1
+ PWR1 - + PWR2 -
COM -
F- R- GND GND C
F+ R+ EOL RST NC FACP + PS1 - + BAT - + PS2 - + BAT -
NO C NC COM NO C NC COM NO C NC COM NO C NC COM NO C NC COM NO C NC COM NO C NC COM NO C NC COM
+PWR2
+PWR1
NC C NO
BAT AC
Tamper
NC C NO
+ INP1 -+INP2 -+INP3 -+INP4 -
+ INP5 -+INP6 -+INP7 -+INP8 -
Altronix LINQ8ACM(CB)
To IEC connector
To LED lense
Pem
Spacer
Backplane
Pan Head Screw
Mercury Board
Fig. 6a
Altronix
eFlow104NB
Fig. 6

T2RM7F8S(D)Q Installation Guide - 5 -
Notes:

- 6 - T2RM7F8S(D)Q Installation Guide
Notes:

T2RM7F8S(D)Q Installation Guide - 7 -
Notes:

- 8 - T2RM7F8S(D)Q Installation Guide
Trove2R Enclosure Dimensions (H x W x D approximate):
3.375” x 19.0” x 33.25” (85.8mm x 482.6mm x 844.6mm). Shown with Z Bracket attached.
Altronix is not responsible for any typographical errors. Product specifications are subject to change without notice.
––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
140 58th Street, Brooklyn, New York 11220 USA | phone: 718-567-8181 | fax: 718-567-9056
IIT2RM7F8S(D)Q F08W MEMBER
39.76” (1,001mm)
33.6” (853.4mm)
4.2” (106.7mm)
11.2” (284.5mm)
0.52” (13.2mm)
0.63” (16mm)
15.05” (382.3mm)
4.5” (114.3mm)
5.35” (135.9mm)
0.72”
(18.3mm)
15.14” (384.4mm)
1.5”
(38.1mm)