TMV2 - Altronix / Mercury / HID VertX Door Backplane - 3 -
TMV2: Configuration of HID VertX®and/or Altronix Boards
HID VertX®Access Controllers:
1. Fasten standoffs (provided) to pems which match the hole pattern for HID VertX®V100, V200, V300, V1000 or V2000 boards
(Fig. 2, pg. 3).
2. Mount boards to standoffs (Fig. 2, pg. 3) utilizing 7/8” pan head screws (provided).
3. Fasten backplane to Trove2 enclosure door utilizing lock nuts (provided).
Altronix Sub-Assemblies and/or Adapters:
1. Fasten nylon / snap on standoffs to pems which match the hole pattern for Altronix Sub-Assemblies (Fig. 1, 1a, pg. 2).
2. Mount boards to standoffs utilizing pan head screws provided with the product or by depressing board onto snap on standoff
(Fig. 1, pg. 2).
Note: For GB1 please use standoffs supplied with the adapter.
Access Controller Position Chart for the Following Models:
HID VertX®
Access Controller Pem Mounting
V100, V200, V300, V1000 or V2000 A
Altronix
Sub-Assembly or Adapter Pem Mounting
ACM4(CB), MOM5, PD4UL(CB), PD8UL(CB), PDS8(CB), VR6, GB1 (Genetec Synergis Cloud Link adapter plate) B
Fig. 2
Pem
Standoff
Access Controller
or Sub-Assembly Backplane
Pan Head
Screw
Fig. 2a