Altronix TROVE T1KE34DV User manual

Access & Power Integration
T1KE34DV
4 Door Kit with PTC Outputs
Fully assembled kit includes:
- Trove1 enclosure with TLU1 backplane
- One (1) AL600XB220 - Power Supply/Charger
- One (1) ACM4CB - PTC Access Power Controller
T1KE38DV
8 Door Kit with PTC Outputs
Fully assembled kit includes:
- Trove1 enclosure with TLU1 backplane
- One (1) AL600XB220 - Power Supply/Charger
- Two (2) ACM4CB - PTC Access Power Controllers
T2KE3316DV
16 Door Kit with PTC Outputs
Fully assembled kit includes:
- Trove2 enclosure with TLU2 backplane
- Two (2) AL600XB220 - Power Supply/Charger
- Two (2) ACM8CB - PTC Access Power Controllers
Installation Guide
All components of this Trove kit are UL Listed sub-assemblies.
Please refer to the included corresponding Sub-Assembly Installation Guides for further information.
All registered trademarks are property of their respective owners. More than just power.™
Rev. 122221
Installing Company: _________________________ Service Rep. Name: ____________________________________________
Address: _________________________________________________________ Phone #: ___________________________

- 2 - T1KE34DV/38DV / T2KE3316DV Installation Guide
Overview:
Altronix Trove Kisi kits are pre-assembled and consists of Trove1LU1 or Trove2LU2 enclosure/backplane with factory installed Altronix power
supply/charger and sub-assemblies. Trove Kisi kits also accommodates up to four (4) Kisi Pro Controllers for up to sixteen (16) doors in a single
enclosure.
Configuration Chart:
Altronix
Model Num-
ber
Power
Supply
Board
Input
Fuse
Rating
Power
Supply
Board
Battery
Fuse
Rating
220VAC
50/60Hz
Input
Current
(A)
Maximum Supply
Current for Main Output on
Power Supply board
and ACM4CB/ACM8CB
Access Power Controllers’
outputs
Nominal DC
Output Voltage
Fail-Safe/
Fail-Secure
Outputs
ACM4CB/
ACM8CB
Board
Input
Fuse
Rating
ACM4CB/
ACM8CB
Board
Output
PTC
Rating
[DC] [Aux]
Output
Range
(VDC)
Output
Range
(VDC)
T1KE34DV
5A/
250V
10A/
32V 1.5 24VDC @ 6A 20.17-
26.4
20.28-
26.4
4
10A/
250V 2A
T1KE38DV 8
T2KE3316DV 16
Installation Instructions:
Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI, and with all local codes and authorities having juris-
diction. Product is intended for indoor use only.
1. Remove backplane from enclosure. Do not discard hardware.
2. Mark and predrill holes in the wall to line up with the top two/three keyholes in the enclosure. Install two/three upper fasteners
and screws in the wall with the screw heads protruding. Place the enclosure’s upper keyholes over the two/three upper
screws, level and secure. Mark the position of the lower two/three holes. Remove the enclosure. Drill the lower holes and
install the two/three fasteners. Place the enclosure’s upper keyholes over the two/three upper screws. Install the two/three lower
screws and make sure to tighten all screws refer to pages 6-7.
3. Mount included UL Listed tamper switch (Altronix Model TS112 or equivalent)
in desired location, opposite hinge. Slide the tamper switch bracket onto the edge
of the enclosure, approximately 2” from the right side (Fig. 1, pg. 2).
Connect tamper switch wiring to the Access Control Panel input or the
appropriate UL Listed reporting device. To activate alarm signal
open the door of the enclosure.
4. Mount Kisi Pro Controllers to TLU1 or TLU2 backplane, refer to pages 3-5.
5. Refer to the ULXB Power Supply/Charger Installation Guide for AL600XB220
and corresponding Sub-Assembly Installation Guides for ACM4CB/ACM8CB for
further installation instructions.
Fig. 1
Tamper Switch
(included)
To Access Control Panel or
UL Listed Reporting Device
Edge of
Enclosure
Enclosure

T1KE34DV/38DV / T2KE3316DV Installation Guide - 3 -
T1KE34DV: Configuration of Kisi Pro Controllers:
1. Fasten mounting magnets (provided) to Kisi Pro Controllers with screws and spacers (provided) using the controllers’ mounting holes
(Fig. 2, pg. 3).
2. Attach mounting magnets to TLU1 in the approximate position as shown below (Fig. 2, pg. 3).
Note: Kisi Pro Controllers should be properly oriented.
Please make sure that they are mounted correctly, as shown in Fig. 2 below.
3. Fasten TLU1 backplane to Trove1 enclosure utilizing hardware (provided).
Access Controller Position Chart for the Following Models:
Kisi Pem Mounting
Pro Controller A
Fig. 2 - T1KE34DV Configuration
ACM4(CB)
TRG
TRIGGER
INPUT
ACM4
ACCESS POWER
CONTROLLER
LED1 LED2 LED3 LED4
MAIN
OUTPUT 1
NC C NO COM NC C NO COM NC C NO COM NC C NO COM
OUTPUT 2 OUTPUT 3
IN GND
1
IN GND
2
IN GND
3
IN GND
4
OUTPUT 4
-- +
CONTROL
-- +
POWER
+INP- T +RET-
INTERFACE
NO C NC
FACP
A
L G N
AC DC BAT
+ BAT - + DC -
NC C NO NC C NOBAT FAIL AC FAIL
Power Supply

- 4 - T1KE34DV/38DV / T2KE3316DV Installation Guide
T1KE38DV: Configuration of Kisi Pro Controllers:
1. Fasten mounting magnets (provided) to Kisi Pro Controllers with screws and spacers (provided) using the controllers’ mounting holes
(Fig. 3, pg. 4).
2. Attach mounting magnets to TLU1 in the approximate position as shown below (Fig. 3, pg. 4).
Note: Kisi Pro Controllers should be properly oriented.
Please make sure that they are mounted correctly, as shown in Fig. 3 below.
3. Fasten TLU1 backplane to Trove1 enclosure utilizing hardware (provided).
Access Controller Position Chart for the Following Models:
Kisi Pem Mounting
Pro Controller A
Fig. 3 - T1KE38DV Configuration
ACM4(CB)
TRG
TRIGGER
INPUT
ACM4
ACCESS POWER
CONTROLLER
LED1 LED2 LED3 LED4
MAIN
OUTPUT 1
NC C NO COM NC C NO COM NC C NO COM NC C NO COM
OUTPUT 2 OUTPUT 3
IN GND
1
IN GND
2
IN GND
3
IN GND
4
OUTPUT 4
-- +
CONTROL
-- +
POWER
+INP- T +RET-
INTERFACE
NO C NC
FACP
TRG
TRIGGER
INPUT
ACM4
ACCESS POWER
CONTROLLER
LED1 LED2 LED3 LED4
MAIN
OUTPUT 1
NC C NO COM NC C NO COM NC C NO COM NC C NO COM
OUTPUT 2 OUTPUT 3
IN GND
1
IN GND
2
IN GND
3
IN GND
4
OUTPUT 4
-- +
CONTROL
-- +
POWER
+INP- T +RET-
INTERFACE
NO C NC
FACP
ACM4(CB)
AA
L G N
AC DC BAT
+ BAT - + DC -
NC C NO NC C NOBAT FAIL AC FAIL
Power Supply

T1KE34DV/38DV / T2KE3316DV Installation Guide - 5 -
T2KE3316DV: Configuration of Kisi Pro Controllers:
1. Fasten mounting magnets (provided) to Kisi Pro Controllers with screws and spacers (provided) using the controllers’ mounting holes
(Fig. 4, pg. 5).
2. Attach mounting magnets to TLU2 in the approximate position as shown below (Fig. 4, pg. 5).
Note: Kisi Pro Controllers should be properly oriented.
Please make sure that they are mounted correctly, as shown in Fig. 4 below.
3. Fasten TLU2 backplane to Trove2 enclosure utilizing hardware (provided).
Access Controller Position Chart for the Following Models:
Kisi Pem Mounting
Pro Controller A
Fig. 4 - T2KE3316DV Configuration
OUTPUT 1 OUTPUT 2 OUTPUT 3 OUTPUT 4 OUTPUT 5 OUTPUT 6 OUTPUT 7 OUTPUT 8
NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM
IN GND IN GND IN GND IN GNDIN GND IN GND IN GND IN GND
1 2 3 4 5 6 7 8
INPUT
TRIGGER
+INP- T + RET-
NO C NC
FACP INTERFACE
Power Control
- + - +
F1 F2 F3 F4 F5 F6 F7 F8
TRG
FACP
1 2 3 4
ON
1 2 3 4
ON
OUTPUT 1 OUTPUT 2 OUTPUT 3 OUTPUT 4 OUTPUT 5 OUTPUT 6 OUTPUT 7 OUTPUT 8
NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM
IN GND IN GND IN GND IN GNDIN GND IN GND IN GND IN GND
1 2 3 4 5 6 7 8
INPUT
TRIGGER
+INP- T + RET-
NO C NC
FACP INTERFACE
Power Control
- + - +
F1 F2 F3 F4 F5 F6 F7 F8
TRG
FACP
1 2 3 4
ON
1 2 3 4
ON
ACM8(CB)
Power Supply
Power Supply
ACM8(CB)
A
A
A
A
L G N
AC DC BAT
+ BAT - + DC -
NC C NO NC C NOBAT FAIL AC FAIL
L G N
AC DC BAT
+ BAT - + DC -
NC C NO NC C NOBAT FAIL AC FAIL

- 6 - T1KE34DV/38DV / T2KE3316DV Installation Guide
T1KE34DV/T1KE38DV Enclosure Dimensions (H x W x D approximate):
18” x 14.5” x 4.625” (457mm x 368mm x 118mm)
4.5” (114.3mm) 4.5” (114.3mm) 2.75”
(69.9mm)
1.115” (28.3mm)
1.36” (34.5mm)
1.25” (31.8mm) 1.25” (31.8mm)
1.5” (38.1mm)
8.5” (215.9mm)6.5” (165.1mm)
1.5” (38.1mm)
8.5” (215.9mm)6.5” (165.1mm)
4.5” (114.3mm)
13.0” (330.2mm)
0.6” (15.2mm)
14.5” (321.3mm)
1.45” (36.8mm)
7.25” (184.2mm)
1.95” (49.5mm)
1.1” (27.9mm)
0.6” (15.2mm)
0.57” (14.5mm)
18.0” (457.2mm)
1.25” (31.8mm)

T1KE34DV/38DV / T2KE3316DV Installation Guide - 7 -
T2KE3316DV Enclosure Dimensions (H x W x D approximate):
27.25” x 21.5” x 6.5” (692.2mm x 552.5mm x 165.1mm)
6.75” (171.5mm)8.25” (209.5mm)
8.00” (203.2mm)
2.00” (50.8mm)
2.00” (50.8mm)
1.25” (31.8mm)
1.25” (31.8mm)
5.25” (133.4mm) 5.25” (133.4mm)7.00” (177.8mm)
1.25” (31.8mm)
6.25” (158.8mm) 19.80” (502.9mm)
1.00” (25.4mm)
27” (685.8mm)
1.5”
(38.1mm)
2.00” (50.8mm) 2.00” (50.8mm)
3.5”(88.9mm) 3.5”(88.9mm)
21.50” (546.1mm)
5.25” (133.35mm) 5.25” (133.35mm)
6.25” (158.8mm)
1.25”
(31.8mm)
0.85” (21.6mm)
0.5625” (14.3mm)
2.415” (61.3mm)
0.685” (17.4mm)
1.77”
(45mm)
0.885” (22.5mm)
1.125” (28.3mm)
Knockouts
2.00” (50.8mm) 2.00” (50.8mm)

- 8 - T1KE34DV/38DV / T2KE3316DV Installation Guide
Altronix is not responsible for any typographical errors.
––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
140 58th Street, Brooklyn, New York 11220 USA | phone: 718-567-8181 | fax: 718-567-9056
IIT1KE34DV/38DV / T2KE3316DV L27U MEMBER
Notes:
This manual suits for next models
2
Table of contents
Popular Door Opening System manuals by other brands

Assa Abloy
Assa Abloy Adams Rite EX76W Preparation and installation guide

Assa Abloy
Assa Abloy Corbin Russwin PED5600 Series installation instructions

Tormax
Tormax iMotion 1401 manual

BFT
BFT LUX BT 2B installation manual

Cal-Royal
Cal-Royal CR801 Series installation instructions

Iseo
Iseo IS 9100 Mounting and Commissioning instructions