CAT. NO. SRPPH02
*NOTE: Do not exceed either maximum weight or width when choosing proper quantity of hinges.
Specifications:
Glass Sizes: 1/2"(12mm) thick tempered safety glass
Construction: Solid brass
Closing Type: Self-centering when within 15° of closed position
Includes: Gaskets, screws and template
Important Information:
Template Options: The Glass-to-Glass Mount SRPPH02 Hinge offers two choices
of templates. Refer to the lower left hand corner of this page for the various
selections. The Edge Mount Template has a full leg cutout that allows a full length
vertical seal on the hinge side.
The Inset Mount Template enables the door to avoid hitting a towel bar, or some
other protrusion from the wall.
Optional Pivot Pins: Optional 5° Pivot Pins (Cat. No. SRP1VP1N) are sold as a set,
one pin for the top hinge and one pin for the bottom hinge. These 5° offset Pivot
Pins allow the installer to adjust the closing position of the door 5° inwards or
outwards. closing position of the door 5° inwards or outwards.
Use of Gaskets:
For 1/2" Glass: Use one thin gasket on one side and one thick gasket on the other side
For 12mm Glass: Use one thick gasket on both sides
Recommendations:
For public safety, we recommend the use of only tempered safety glass. Do
not use power tools when installing these hinges.
Maintenance Guidelines:
• Never use an abrasive cleaner on the hardware. Many of the components are
coated with a clear lacquer that will be irreparably damaged if subjected to
harsh, abrasive chemicals. Advise your customer that drying the hardware with
a clean, soft towel on a daily basis is the best way to maintain the hardware. If
mineral deposits build-up, mix a couple of drops of a mild liquid soap (such as
Ivory or a similar product) into a cup of warm water. Using a soft, non-abrasive
cloth, clean the hardware. Rinse thoroughly with clean, warm water and dry.
Maximum Door Capacities Two Hinges
Maximum Door Weight: 145 lbs.(66 kg)
Maximum Door Width: 36"(914mm)
C.R. LAURENCE CO., INC.
4H-1
C.R. Laurence Co., Inc.
crlaurence.com
Specifications:
Glass Sizes: 1/2"(12mm) thick tempered safety glass
Construction: Solid brass
Closing Type: Self-centering when within 15˚ of closed position
Cutout Required
Includes: Gaskets, screws and template
Use of Gaskets:
For 1/2" Glass: Use one thin gasket on one side and one thick gasket on the other side
For 12mm Glass: Use one thick gasket on both sides
Recommendations:
For public safety, we recommend the use of only tempered safety glass.
Do not use power tools when installing these hinges.
Important Information:
Template Options: The Top or Bottom Mount SRPPH01 Hinge offers two choices of templates. Refer to
the lower left hand corner of this page for the selections. The Edge Mount Template has a full leg cutout
that allows a full length vertical seal on the hinge side.
The Inset Mount Template enables the door to avoid hitting a towel bar, or some other protrusion from the wall.
Optional Pivot Pins: Optional 5˚ Pivot Pins (Cat. No. SRP1VP1N) are sold as a set, one pin for the top
hinge and one pin for the bottom hinge. These 5˚ offset Pivot Pins allow the installer to adjust the closing
position of the door 5˚ inwards or outwards.
*NOTE: Do not exceed either maximum weight or width when choosing proper quantity of hinges.
*Maximum
Door Capacities
Using 2 Hinges
145 lbs.(66 kg) 36"(914mm)
1/2" (12mm) Glass
Weight Width
Maintenance Guidelines:
• Never use an abrasive cleaner on the hardware. Many of the components are coated with a clear lacquer
that will be irreparably damaged if subjected to harsh, abrasive chemicals. Advise your customer that
drying the hardware with a clean, soft towel on a daily basis is the best way to maintain the hardware.
If mineral deposits build-up, mix a couple of drops of a mild liquid soap (such as Ivory or a similar
product) into a cup of warm water. Using a soft, non-abrasive cloth, clean the hardware. Rinse
thoroughly with clean, warm water and dry.
SENIOR PRIMA
Top or Bottom Mount Hinge
CAT. NO. SRPPH01
Edge Mount Method (9/16" (14mm) Clearance) . . . . . . . . .Page 4H-2
Inset Mount Method (9/16" (14mm) Clearance) . . . . . . . . .Page 4H-3
Refer to Dimensions Shown
to Ensure Accuracy
* SEE TEMPLATE ON BACK *
C.R. LAURENCE CO., INC.
PROFESSIONAL QUALITY
C.R. Laurence Corporate Headquarters: P.O. Box 58923 Los Angeles, CA 90058-0923; Toll Free Phone (800) 421-6144, Technical Assistance/Extension 777; Toll Free Fax (800) 587-7501
Specifications:
Glass Sizes: 1/ 2”(12mm) thick tempered safety gl ass
Constructi on: Solid brass
Closi ng Type: Sel f- centeri ng when withi n 15˚ of closed posi tion
Cutout Required Incl udes: Gasket s, scr ews and templ at e
Use of Gaskets:
For 1/2" Glass: Use one thin gasket on one si de and one thick gasket on the other side
For 12mm Glass: Use one thi ck gasket on both si des
Recommendati ons:
For publi c safety, we recommend the use of only tempered safety glass.
Do not use power tools when i nstal l i ng these hinges.
Important Informati on:
Templ ate Options: The Gl ass- to- Gl ass Mount SRPPH02 Hi nge offers t wo choi ces of templ ates. Refer
to the l ower left hand corner of this page for the vari ous sel ections. The Edge Mount Template has a ful l
leg cutout that allows a ful l length verti cal seal on the hi nge si de.
The Inset Mount Template enables the door to avoid hitting a towel bar, or some other protrusi on from
the wal l .
Opti onal Pivot Pi ns: Opt i onal 5˚ Pi vot Pi ns (Cat . No. SRP1VP1N) are sol d as a set , one pi n for the
top hi nge and one pi n for the bottom hinge. These 5˚ offset Pi vot Pi ns al l ow the instal l er to adjust the
closing positi on of the door 5˚ inwards or outwards.
4H-5
4-3/4"
(121mm)
2- 5/8"
(67mm)
2- 5/8"
(67mm)
1/8"
(3mm)
©Copyright 2001, C.R. Laurence Co., Inc.
Maintenance Gui del i nes:
• Never use an abrasi ve cl eaner on the har dware. Many of the components are coat ed wi th a cl ear l acquer
that wi l l be irreparabl y damaged if subjected to harsh, abrasi ve chemi cals. Advi se your customer that
dryi ng the hardware wi th a cl ean, soft towel on a dai l y basis i s the best way to maintai n the hardware.
If mi neral deposi ts bui l d- up, mix a coupl e of drops of a mi l d l i qui d soap (such as Ivory or a si mil ar
product) into a cup of warm water. Usi ng a soft, non- abrasive cl oth, cl ean the hardware. Rinse
thoroughly with cl ean, warm water and dry.
* NOTE: Do not exceed either maximum weight or width when choosing proper quantity of hinges.
* Maximum
Door Capacities
Using 2 Hinges
145 lbs.(66 kg) 36"(914mm)
1/2" (12mm) Glass
Weight Width
SENIOR PRIMA
Glass-to-Glass Hinge
CAT NO. SRPPH02
Edge Mount Method (1/8" (3mm) to 3/16" (5mm) Clearance) . . . . .Page 4H-6
Inset Mount Method (1/8" (3mm) to 3/16" (5mm) Clearance) . . . . .Page 4H-7


This manual suits for next models
1
Other CRL Door Opening System manuals
Popular Door Opening System manuals by other brands

Dorma
Dorma 9800FL Series manual

Dormakaba
Dormakaba ED50 owner's manual

Tormax
Tormax iMotion 1301.FIRE Instructions for use

Assa Abloy
Assa Abloy DC700G-FMS-K installation instructions

Assa Abloy
Assa Abloy Norton UniTrol UNI-1600BC Series installation instructions

Elvox
Elvox Sound system GIOTTO operating instructions