- 2 - ALTV244220 Series
Overview:
Altronix ALTV244220 Series CCTV Power Supplies provide 24VAC or 28VAC distributed via four (4) fuse or
PTC protected outputs for powering CCTV cameras, heaters and other video accessories.
Four (4) Output ALTV244 Reference Chart:
Altronix
Model Number
Total
Output
Current
Output
Voltage
Number of
Outputs
PTC Protected
Outputs
(auto-resettable)
Fuse Protected
Outputs
Output Current
(max per output)
Main
Fuse Ratings
220VAC
50/60Hz
Input Current
ALTV244220 4A 24VAC
4
–P3.5A 5A/
250V 0.5A
3.5A 28VAC
ALTV244CB220 4A 24VAC P– 2.5A
3.5A 28VAC
ALTV244175220 7.25A 24VAC –P3.5A 10A/
250V 0.8A
6.25A 28VAC
ALTV244175CB220 7.25A 24VAC P– 2.5A
6.25A 28VAC
ALTV244300220 12.5A 24VAC –P3.5A 15A/
32V 1.8A
10A 28VAC
ALTV244300CB220 10A 24VAC P– 2.5A
10A 28VAC
Specifications:
Installation Instructions:
1. Mount unit in the desired location. Mark and predrill holes in the wall to line up with the top two keyholes
in the enclosure. Install two upper fasteners and screws in the wall with the screw heads protruding. Place
the enclosure’s upper keyholes over the two upper screws; level and secure. Mark the position of the lower
two holes. Remove the enclosure. Drill the lower holes and install the fasteners. Place the enclosure’s upper
keyholes over the two upper screws. Install the two lower screws and make sure to tighten all screws
(Enclosure Dimensions, pg. 7, 8). Secure enclosure to earth ground.
2. Slide switch SW1 to the OFF position on models ALTV244220 and ALTV244CB220 (Fig. 1, pg. 4).
Turn main switch on all other models to the OFF position (Figs. 2, 3, pgs. 5, 6).
3. All units are factory set for 24VAC operation.
For 28VAC operation adjust unit prior to mounting and applying power as follows: Change the wire position
so that the black wire [28V] is connected to the terminal marked [P] and the yellow wire [24V] is connected
to the terminal marked [S].
4. Connect unswitched AC circuit (220VAC, 50/60Hz) as follows: Green branch wire (ground) connects to the
terminal marked , Line connects to the terminal marked [L], and Neutral connects to the terminal marked
[N] of the Inlet Appliance Connector. (Figs. 1-3, pgs. 4-6).
Use 18 AWG or larger for all power connections (Battery, AC output).
Agency Listing:
• CE European Conformity.
Input:
• 220VAC (working range 198VAC - 256VAC),
50/60Hz.
Output:
• Four (4) fuse or PTC protected outputs.
• 24VAC or 28VAC supply current.
• Outputs are rated @ 3.5A (fused) or 2.5A (PTC).
• Surge suppression.
Features:
• Slow blow main fuse on power distribution board.
• AC power LED.
• Power ON/OFF switch.
• Spare fuses provided.
(all models w/primary and/or secondary fuses).
Enclosure Dimensions:
• ALTV244220 and ALTV244CB220:
8.5” x 7.5” x 3.5” (215.9mm x 190.5mm x 88.9mm).
• ALTV244175220, ALTV244175CB220,
ALTV244300220, and ALTV244300CB220:
8.5” x 7.5” x 3.875” (215.9mm x 191mm x 98.4mm).