amazipoint W708 User manual

Version:0.6
OEM/Integrators Installation Manual
Date: 2017.5.18
Copyright © amazipoint technology Ltd. All rights are reserved. Page 1 of 13
OEM/Integrators Installation Manual
Version Issue date Changes Remark
0.1 2015/9/04 Initial Version
0.2 2015/10/22 Update GPIO sharing scheme
0.3 2015/11/30 Update package information. Correct PERST_N
0.4 2015/12/1 Update industrial and commercial grade information
0.5 2016/10/15 GPIO : Link2 change to UART_TXD2
0.6 2017/5/18 Update FCC approval information, Correct GPIO 27, 28, 29
IMPORTANT
This document contains important Information and therefore
should not be disclosed to third parties without prior written consent of amazipoint technology Ltd.
Address︰
︰︰
︰2F, No. 113, Zhongyang Rd., Xindian Dist., New Taipei City, Taiwan(R.O.C)
www.amazipoint.com
Signature:
Author: Reviewed by: Approved by: Remarks:
Martin Ho

Version:0.6
OEM/Integrators Installation Manual
Date: 2017.5.18
Copyright © amazipoint technology Ltd. All rights are reserved. Page 2 of 13
1. Introduction
W708 module is designed for easy-design-in low cost Wifi application。It has WAN, LAN, UART, I2C,
SPI, I2S, SDXC and GPIO interfaces. Support 1T1R 150N operation. 3.3V single power supply.
There are industrial grade and commercial grade two different configuration. For industrial grade, we use
industrial grade DDR2 memory. component. For commercial grade, we use commercial grade DDR2 memory.
component.
2. Technical specification
a. Channel Plan
country code region channel
0 North America CH1 ~ 11
1 Others CH1 ~ 13
5 Japan CH1 ~ 14
6 CH3 ~ 9
7 CH5 ~ 13
MT7688AN
2 B2B
Socket
1.8V
switching
regulator
64MB
DDR2
8MB
SPI
FLASH
RF
0
40MHz
Crystal
3.3V
1.8V

Version:0.6
OEM/Integrators Installation Manual
Date: 2017.5.18
Copyright © amazipoint technology Ltd. All rights are reserved. Page 3 of 13
Note : The country code is configured before shipping and can not be changed by user.
b. Specification Table
Items Specification
Supported Standard and Protocol
IEEE 802.11n, IEEE 802.11g, IEEE 802.11b, IEEE 802.3, IEEE
802.3u, CSMA/CA, CSMA/CD,TCP/IP,DHCP, ICMP, NAT, PPPoE
Dimension 35*25 mm
Power consumption < 250mA, 180mA typical
Operating Temperature Range
-30 ~ 80 deg. C ( for commercial grade )
-40 ~ +85 deg. C ( for industrial grade )
Storage Temperature Range -40 ~ 90 deg. C
Humidity < 90%
WAN Port one 10/100M adaptive RJ45 port
LAN Port one 10/100M adaptive RJ45 port
RF Parameters
Frequency
Range
2.412~2.4835GHz, depends on country code, maybe 2.412~2462 or
2.412~2.472GHz
Baud Rate
1T1R :
MCS Data rate (Mbit/s)
index 20 MHz channel 40 MHz channel
800 ns 400 ns 800 ns 400 ns
0 6.5
7.2
13.5
15
1 13
14.4
27
30
2 19.5
21.7
40.5
45
3 26
28.9
54
60
4 39
43.3
81
90
5 52
57.8
108
120
6 58.5
65
121.5
135
7 65
72.2
135
150
IEEE 802.11g
:
54/48/36/24/18/12/9/6(adaptive )
IEEE 802.11b
:
11/5.5/2/1M(adaptive )

Version:0.6
OEM/Integrators Installation Manual
Date: 2017.5.18
Copyright © amazipoint technology Ltd. All rights are reserved. Page 4 of 13
Number of
Channel
Support channel 1 ~14, actual channel numbers depends on setting of country
code
Modulation
Scheme
DBPSK
、
DQPSK
、
CCK and OFDM(BPSK/QPSK/16-QAM/64-QAM)
Sensitivity @
PER
150M
:
-68dBm@10% PER
;
130M
:
-68dBm@10% PER
;
108M
:
-68dBm@10% PER
;
54M
:
-72dBm@10% PER
11M
:
-85dBm@8% PER
;
6M
:
-88dBm@10% PER
1M
:
-90dBm@8% PER
;
Output Power
802.11b: 16 dBm ± 1.5dBm@11Mbps (1T1R total power)
802.11g: 14.5 dBm ± 1.5dBm@54Mbps
802.11n HT20: 14.5 dBm ± 1.5dBm @MCS7
802.11n HT40: 14.5 dBm ± 1.5dBm @MCS7
Antenna One IPEX I connectors for one external antenna( 1T1R)
WIFI Operation Mode Client/AP
System Service Virtual Server
:
Internal web server for browser to access
Device Management
Area setting
Restore to default factory setting
Software upgrade
Reboot
Change password
WLAN Security Mode
OPENWEP
SHAREDWEP
WEPAUTO
WPA
WPA-PSK
WPA2
WPA2-PSK
WPAPSKWPA2PSK
WPA1WPA2(WPA and WPA2 hybrid mode)

Version:0.6
OEM/Integrators Installation Manual
Date: 2017.5.18
Copyright © amazipoint technology Ltd. All rights are reserved. Page 5 of 13
802.1x
3. Software features
•
Support WPS
•
Support AP(Access point)、Client(Wifi Station) mode
•
AP mode
o
Default operation mode. In this mode, the module work as an Access Point, don't need any
configuration.
o
User can use PC via RJ45 or smart phone via Wifi to login AP mode and change the
default configuration ( through browser).
•
Client mode
o
In this mode, module is a Wifi station.
4. Development tool :
We provide development tool for easy connection of power, RS-232, LAN, WAN, and USB port.
5. Module Dimension : 35*25 mm

Version:0.6
OEM/Integrators Installation Manual
Date: 2017.5.18
Copyright © amazipoint technology Ltd. All rights are reserved. Page 6 of 13
There are two 1.27mm pitch header on the bottom side of module P1 and P2.
6. Pin Assignment
Bottom view for showing P1, P2 and pin 1/pin 2 position on bottom side of W708 module :
P1 :

Version:0.6
OEM/Integrators Installation Manual
Date: 2017.5.18
Copyright © amazipoint technology Ltd. All rights are reserved. Page 7 of 13
Multi 1
Multi 1Multi 1
Multi 1
Multi 2
Multi 2Multi 2
Multi 2 GPIO
GPIOGPIO
GPIO Main
MainMain
Main Main
MainMain
Main GPIO
GPIOGPIO
GPIO Multi 2
Multi 2Multi 2
Multi 2 Multi 1
Multi 1Multi 1
Multi 1
GPIO23 SD_CDT 1
11
1 2
22
2SD_CMD GPIO27
GPIO25 SD_D0 3
33
3 4
44
4SD_D3 GPIO28
GPIO24 SD_D1 5
55
5 6
66
6SD_D2 GPIO29
GPIO22 SD_WP 7
77
7 8
88
8SD_CLK GPIO26
GPIO37 REF_CLKO 9
99
9 10
1010
10 POR
GPIO39 LINK4 11
1111
11 12
1212
12 GPIO0 GPIO11 REFCLK
GPIO40 LINK3 13
1313
13 14
1414
14 SPI_MISO GPIO9
GPIO6 SPI_CS1 15
1515
15 16
1616
16 TXD0 GPIO12
GPIO7 SPI_CLK 17
1717
17 18
1818
18 RXD0 GPIO13
GPIO20 URAT_TXD2 19
1919
19 20
2020
20 SPI_MOSI GPIO8
P2 :
Multi 1
Multi 1Multi 1
Multi 1 Multi 2
Multi 2Multi 2
Multi 2 GPIO
GPIOGPIO
GPIO Main
MainMain
Main Main
MainMain
Main GPIO
GPIOGPIO
GPIO Multi 2
Multi 2Multi 2
Multi 2 Multi 1
Multi 1Multi 1
Multi 1
GPIO4 I2C_SCLK 1
11
1 2
22
2I2C_SD GPIO5
TXO1_P 3
33
3 4
44
4RXI0_P
TXO1_N 5
55
5 6
66
6RXI0_N
GPIO2 I2S_WS 7
77
7 8
88
8LINK0 GPIO43
GPIO36 PERST_N 9
99
9 10
1010
10 GND
PWM_CH1 GPIO46 RXD1 11
1111
11 12
1212
12 USB_P
GPIO38 WDT_RST_N 13
1313
13 14
1414
14 USB_N
3.3VD 15
1515
15 16
1616
16 GND
3.3VD 17
1717
17 18
1818
18 TXO0_P
GPIO1 I2S_DO 19
1919
19 20
2020
20 TXO0_N
PWM_CH0 GPIO45 TXD1 21
2121
21 22
2222
22 RXI1_N
GPIO0 I2S_DI 23
2323
23 24
2424
24 RXI1_P
GPIO42 LINK1 25
2525
25 26
2626
26 I2S_CLK GPIO3
GPO44 WL N_LED 27
2727
27 28
2828
28 U RT_RXD2 GPIO21
P1 :
Pin # Function Direction Description
1 SD_CDT In SDXC Card Detect
2 SD_CMD Out SDXC Command
3 SD_D0 In/Out SDXC Data0
4 SD_D3 In/Out SDXC Data3

Version:0.6
OEM/Integrators Installation Manual
Date: 2017.5.18
Copyright © amazipoint technology Ltd. All rights are reserved. Page 8 of 13
5 SD_D1 In/Out SDXC Data1
6 SD_D2 In/Out SDXC Data2
7 SD_WP In SDXC Write Protect
8 SD_CLK Out SDXC Clock
9 REF_CLKO Out Reference clock output
10 POR In Power on reset input, low active
11 LINK4 Out Link LED for port 4
12 GPIO0 Out GPIO0 or WPS push button
13 LINK3 In/Out Link LED for port 3
14 SPI_MISO In SPI MISO signal
15 SPI_CS1 Out SPI chip select signal 1
16 TXD0 A Console UART TXD signal
17 SPI_CLK Out SPI clock output
18 RXD0 A Console UART RXD signal
19 LINK2 Out Link LED for port 2
20 SPI_MOSI Out SPI MOSI signal
P2 :
Pin # Function Direction Description
1 I2C_SCLK In/Out I2C Clock signal
2 I2C_SD In/Out I2C Data signal
3 TXO1_P A Tx positive for port 1
4 RXI0_P A Rx positive for port 0
5 TXO1_N A Tx negative for port 1
6 RXI0_N A Rx negative for port 0
7 I2S_WS I2S word select
8 LINK0 Out Link LED for port 0
9 PERST_N PCIe device reset
10 GND Power ground
11 RXD1 UART1 RXD signal
12 USB_P In/Out USB signal poistive
13 WDT_RST_N Out Watchdog reset
14 USB_N In/Out USB signal negative
15 3.3VD Power In 3.3V input
16 GND Power ground

Version:0.6
OEM/Integrators Installation Manual
Date: 2017.5.18
Copyright © amazipoint technology Ltd. All rights are reserved. Page 9 of 13
17 3.3VD Power In 3.3V input
18 TXO0_P A Tx positive for port 0
19 I2S_DO out I2S data out
20 TXO0_N A Tx negative for port 0
21 TXD1 Out UART1 TXD
22 RXI1_N A Rx negative for port 1
23 I2S_DI In I2S data in
24 RXI1_P A Rx positive for port 1
25 LINK1 Out Link LED for port 1
26 I2S_CLK out I2S clock signal
27 WLAN_LED Out WLAN LED output, active low
28 UART_RXD2 In UART2 RXD
7. Memory configuration
Depending on customer's request, the module can be shipped with following configuration :
Flash size : 2MB, 4MB, 8MB, 16MB, 32MB, 64MB
DDR2 size : 64MB, 128MB
8. Mechanical Application Notes
1. CON0 is IPEX1 connectors on top side
2. P1 is 2*10 pins 1.27mm male header on bottom side for signals
3. P2 is 2*14 pins 1.27mm male header on bottom side for signals
4. Footprint of P1, P2 is as following :

Version:0.6
OEM/Integrators Installation Manual
Date: 2017.5.18
Copyright © amazipoint technology Ltd. All rights are reserved. Page 10 of
13
5. There are four slot holes used for installing metal shielding cover if needed
6. There are two diameter 2.1mm holes for screw fixing
7. The mechanical drawing in .dxf format is available under request.
8. Bottom view 2D drawing is as following :
9. Shipping & package information

Version:0.6
OEM/Integrators Installation Manual
Date: 2017.5.18
Copyright © amazipoint technology Ltd. All rights are reserved. Page 11 of
13
W708 is packaged with stacked PS tray :
Tray size : for each element, the size is 45*35*12 mm, there are 8*8 elements for each
tray. There are 25 trays in each carton. So, total 1600 pieces maximum for each
carton.
Carton size : 500 x 400 x 300 mm
Carton Label ( packing list ) :
10. Ordering Information
The part number for placing order is W708-MM-NN-G.
MM is bytes of SPI flash and NN is bytes for DDR2.
G : C for commercial grade or I for industrial grade.
For example with the standard memory configuration 8MB Flash, 64MB DDR2 and
commercial grade, the part number is W708-8-64-I.

Version:0.6
OEM/Integrators Installation Manual
Date: 2017.5.18
Copyright © amazipoint technology Ltd. All rights are reserved. Page 12 of
13
11. FCC Warning Statement
FEDERAL COMMUNICATIONS COMMISSION REGULATIONS
This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment generates, uses and can
radiate radio frequency energy and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the equipment
off and on, the user is encouraged to try to correct the interference by one or more of the
following measures:
– Reorient or relocate the receiving antenna.
– Increase the separation between the equipment and receiver.
– Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
– Consult the dealer or an experienced radio/TV technician for help.
CAUTION:
Any changes or modifications not expressly approved by the party responsible for
compliance could void the user's authority to operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following
two conditions:
(1) This device may not cause harmful interference and
(2) This device must accept any interference received, including interference that may
cause undesired operation.
FCC RF Radiation Exposure Statement
This equipment complies with FCC/IC radiation exposure limits set forth for an uncontrolled
environment. This equipment should be installed and operated with minimum distance 20 cm
between the radiator & your body.
Important Note
In the event that these conditions can not be example certain laptop configurations or
collocation with another transmitter, then the FCC authorization is no longer considered valid the
FCC ID can not be used on the final product. In these circumstances, OEM integrator will be
responsible for re-evaluating the end product (including the transmitter) and obtaining a separate
FCC authorization.
End Product Labeling
When the module is installed in the host device, the FCC ID label must be visible through a window
on the final device or it must be visible when an access panel, door or cover is easily re-moved. If not,
a second label must be placed on the outside of the final device that contains the following text
“Contains FCC ID 2ALWN-W708”
The FCC ID can be used only when all FCC compliance requirements are met.
Manual Information for End Users

Version:0.6
OEM/Integrators Installation Manual
Date: 2017.5.18
Copyright © amazipoint technology Ltd. All rights are reserved. Page 13 of
13
The module is limited to OEM installation ONLY
The module is limited to installation in mobile or fixed applications, according to Part 2.1091(b)
The separate approval is required for all other operating configurations, including portable
configurations with respect to Part 2.1093 and different antenna configurations
The end user must not have manual instructions to remove or install device. The
user manual for end users must include the following information in a prominent
location:
“IMPORTANT NOTE: To comply with FCC RF exposure compliance requirements,
the antenna used for this transmitter must be installed to provide a separation distance of
at least 20 cm from all persons and must not be co-located operating in conjunction with
any other antenna or transmitter.” as a result of e-mail transmission.”
This manual suits for next models
1
Table of contents