Elatec TWN3 MIFARE User manual

TWN3 MIFARE M
USER MANUAL

TABLE OF CONTENTS
1INTRODUCTION.................................................................................................................................................................. 3
1.1 ABOUT THIS MANUAL ..................................................................................................................................................3
1.2 ELATEC SUPPORT........................................................................................................................................................3
1.3 REVISION HISTORY......................................................................................................................................................3
2INTENDED USE .................................................................................................................................................................. 3
3SAFETY INFORMATION ..................................................................................................................................................... 4
4TECHNICAL DATA .............................................................................................................................................................. 5
5MODE OF OPERATION ...................................................................................................................................................... 6
5.1 OPERATING MODE .......................................................................................................................................................6
5.2 POWER UP ....................................................................................................................................................................6
5.3 ENUMERATION .............................................................................................................................................................6
5.4 INITIALIZATION..............................................................................................................................................................6
5.5 NORMAL OPERATION ..................................................................................................................................................6
5.6 DETECTION OF A TRANSPONDER .............................................................................................................................6
5.7 SUSPEND MODE...........................................................................................................................................................7
6COMPLIANCE STATEMENTS ............................................................................................................................................ 8
6.1 EU ...................................................................................................................................................................................8
6.2 RF EXPOSURE COMPLIANCE .....................................................................................................................................8
APPENDIX ....................................................................................................................................................................................... 9
A – TERMS AND ABBREVIATIONS...........................................................................................................................................9
B – RELEVANT DOCUMENTATION ..........................................................................................................................................9

© 2021 ELATEC GmbH – TWN3 MIFARE M user manual DocRev2 – 09/2021 Page 3of 10
1INTRODUCTION
1.1 ABOUT THIS MANUAL
This user manual is intended for the user and enables a safe and appropriate handling of the product. It gives a general overview, as
well as important technical data and safety information about the product. Before using the product, the user should read and
understand the content of this user manual.
For the sake of better understanding and readability, this user manual might contain exemplary pictures, drawings and other
illustrations. Depending on your product configuration, these pictures might differ from the actual design of your product.
1.2 ELATEC SUPPORT
In case of any technical questions, refer to the ELATEC website (www.elatec.com) or contact ELATEC technical support at:
support-rfid@elatec.com
In case of questions regarding your product order or if you wish additional copies of this user manual, contact your Sales representative
or ELATEC customer service at:
info-[email protected]
1.3 REVISION HISTORY
VERSION
CHANGE DESCRIPTION
EDITION
02
Editorial changes, chapters “Safety Information”, “Technical Data” and “Compliance
Statements” updated
09/2021
01
First edition
02/2021
2INTENDED USE
The TWN3 MIFARE M RFID reader module is designed for easy integration into various applications. This device supports either USB
or RS-232 communication just in dependence on the connection cable and is available as an OEM board (PCB) without housing for
direct integration into embedded applications. The reader module can be programmed with a scripting language for autonomous
execution of even complex commands like login procedures, increment/decrement functions and many more.
The product is intended to be integrated into a host device.
Any use other than the intended use described in this section, as well as any failure to observe the safety information listed in this
document, will be considered misuse and will void the warranty. ELATEC is not responsible for any damage or injuries resulting from
any misuse of the product.

© 2021 ELATEC GmbH – TWN3 MIFARE M user manual DocRev2 – 09/2021 Page 4of 10
3SAFETY INFORMATION
Installation
•The installation of the product should be done by a trained and qualified personnel only.
Do not install the product by yourself.
•Metallic materials on or in direct vicinity to the product might reduce the reading performance of the product. In some
circumstances, plastic screws should be preferred to metallic screws when installing the product. Refer to the installation
instructions or integration manual of the product for more information.
Handling
•Depending on your product configuration, the product might be equipped with one or more light-emitting diodes (LED).
Avoid direct eye contact with the blinking or steady light of the light-emitting diodes.
•The product has been designed for a use under following conditions:
oTemperature range: -25 °C – 80 °C (operating conditions)
oRelative humidity: 5% – 95% (non-condensing)
oIntegration into a host device.
Any use of the product under different conditions might damage the product or alter its reading performance.
•The use of other RFID readers or reader modules in direct vicinity to the product, or in combination with the product might damage
the product or alter its reading performance. In case of doubts, contact ELATEC for more information.
•The user is liable for the use of spare parts or accessories other than the ones sold or recommended by ELATEC.
ELATEC is not responsible for any damage or injuries resulting from the use of spare parts or accessories other than the ones
sold or recommended by ELATEC.
•Like most electronic devices, RFID systems generate electromagnetic waves that can vary in amplitude and frequency. It is
generally known and accepted that some RFID devices might potentially interfere with personal medical devices, like pacemakers
or hearing aids.
Users with a pacemaker or any other medical device should use TWN3 MIFARE M carefully and refer to the information
given by the manufacturer of their medical devices before using TWN3 MIFARE M or any host device containing
TWN3 MIFARE M.
Maintenance and cleaning
•Any repair or maintenance work should be done by a trained and qualified personnel only.
Do not try to repair or carry out any maintenance work on the product by yourself.
Do not allow any repair or maintenance work on the product by an unqualified or unauthorized third party.
•The product does not need any special cleaning.
Do not use any detergents or other cleaning agents on the product.
Disposal
•The product must be disposed of in accordance with the EU directive on waste electrical and electronic equipment (WEEE) or
other applicable local regulations.
Product modifications
•The product has been designed, manufactured and certified as defined by ELATEC.

© 2021 ELATEC GmbH – TWN3 MIFARE M user manual DocRev2 – 09/2021 Page 5of 10
Any product modifications not expressly approved by ELATEC, including – but not limited to – modifications of antennas
or other radio-related components, is not allowed and will void the warranty and all approvals granted to the product.
If you are unsure about any part of the safety information above, contact ELATEC support.
Any failure to observe the safety information above will be considered misuse and will void the warranty. ELATEC is not responsible
for any damage or injuries resulting from any misuse of the product.
4TECHNICAL DATA
Power supply
5.0 V ± 10% via communication cable (USB); serial version requires external power supply
Current consumption
55 mA typ. (USB, normal operation); 120 mA peak
Antenna
The reader module is equipped with the following antenna:
TWN3 MIFARE M – HF antenna (PCB air coil, integrated)
HF antenna (13.56 MHz)
Dimensions: 39.5 mm x 48 mm / 1.56 inch x 1.89 inch
Number of turns: 4
For more information, refer to the related product data sheet or other technical documents.

© 2021 ELATEC GmbH – TWN3 MIFARE M user manual DocRev2 – 09/2021 Page 6of 10
5MODE OF OPERATION
5.1 OPERATING MODE
In order to start operating TWN3 MIFARE M, it simply has to be connected directly to a host device.
5.2 POWER UP
In case of an external power supply unit is used, the following requirements must be satisfied:
•Limited power source according to the safety norms listed in the respective declaration of conformity
•Short-circuit current < 8 A
Once a TWN3 MIFARE M reader module is connected to the host, it detects the type of communication cable (USB or RS-232), with
which it is connected to the host. The result of this detection is signaled via the two LEDs:
•USB cable: red LED flashes once.
•RS-232 cable: green LED flashes once. This flash is hidden by the directly following permanent one of the green LED.
In case of RS-232: Additionally, the RS-232 is sending a version string via RS-232 to the host.
5.3 ENUMERATION
This is only applicable for the USB version: Once the device has been powered up, it is waiting for completion of the enumeration by
the USB host. As long as the device is not enumerated, it is entering a minimum power consumption mode, where both LEDs are
turned off.
5.4 INITIALIZATION
After powering up and enumeration (in USB mode), the device is turning on its built-in transponder reader logic. The green LED is
turned on permanently. Some RFID reader modules need some kind of initialization, which is performed in this step. After successful
initialization, the device sounds a short sequence, which consists of a lower tone followed by a higher tone, which is similar to a
“plug & play” sound.
5.5 NORMAL OPERATION
As soon as the reader module has completed the initialization, it is entering normal operation. During normal operation, the reader
module is searching for a transponder continuously.
5.6 DETECTION OF A TRANSPONDER
If a transponder is detected by the reader module, following actions are performed:
•Send the ID to the host. By default, the USB device sends by emulating keystrokes of a keyboard. An RS-232 device sends the
ASCII code of an ID.
•Sound a beep.
•Turn off the green LED.
•Blink the red LED for two seconds.
•Turn on the green LED.
Within the two seconds timeout, where the red LED is blinking, the transponder, which just has been recognized will not be accepted
again. This prevents the reader module from sending identical IDs more than one time to the host.
If during the two seconds timeout of the red LED a different transponder is detected, the complete sequence restarts immediately.

© 2021 ELATEC GmbH – TWN3 MIFARE M user manual DocRev2 – 09/2021 Page 7of 10
5.7 SUSPEND MODE
The USB version of the reader module supports the USB suspend mode. If the USB host is signaling suspend via the USB bus, then
the reader module is turning off most of its power consuming peripherals. During this operation mode, no detection of transponders is
possible and all LEDs are turned off.
Once the host is resuming to normal operation mode, this is also signaled via the USB bus. Therefore, the reader module will resume
to normal operation too.

© 2021 ELATEC GmbH – TWN3 MIFARE M user manual DocRev2 – 09/2021 Page 8of 10
6COMPLIANCE STATEMENTS
6.1 EU
TWN3 MIFARE M is in compliance with the EU directives and regulations as listed in the respective declaration of conformity.
6.2 RF EXPOSURE COMPLIANCE
RF exposure statement (mobile and fixed devices)
This device complies with the RF exposure requirements for mobile and fixed devices. However, the device shall be used in such a
manner that the potential for human contact during normal operation is minimized.

© 2021 ELATEC GmbH – TWN3 MIFARE M user manual DocRev2 – 09/2021 Page 9of 10
APPENDIX
A – TERMS AND ABBREVIATIONS
TERM EXPLANATION
HF
high frequency
LED
light-emitting diode
PCB
printed circuit board
RFID
radio frequency identification
WEEE
Waste of electrical and electronic equipment.
Refers to Directive 2011/65/EU of the European Parliament and of the Council of the European Union
B – RELEVANT DOCUMENTATION
ELATEC documentation
•ELATEC quick start guide
•Transponder Reader TWN3 Technical Manual
•TWN3 MIFARE M data sheet
•TWN3 MIFARE M integration manual

Elatec reserves the right to change any information or data in this document without prior notice. Elatec declines all responsibility for the use of this product with any other specification but the one mentioned above. Any
additional requirement for a specific customer application has to be validated by the customer himself at his own responsibility. Where application information is given, it is only advisory and does not form part of the
specification. Disclaimer: All names used in this document are registered trademarks of their respective owners.
© 2021 ELATEC GmbH – TWN3 MIFARE M user manual DocRev2 – 09/2021
ELATEC GMBH
Zeppelinstr. 1
•82178 Puchheim •Germany
P +49 89 552 9961 0
•F +49 89 552 9961 129 •E-mail: info-rfid@elatec.com
elatec.com
Other manuals for TWN3 MIFARE
4
Table of contents
Other Elatec Control Unit manuals

Elatec
Elatec TWN4 MultiTech 2 HF User manual

Elatec
Elatec TWN4 Slim LEGIC User manual

Elatec
Elatec TWN4 PALON SQUARE M LF HF Use and care manual

Elatec
Elatec TWN3 MINI User manual

Elatec
Elatec TWN3 LEGIC NFC User manual

Elatec
Elatec TWN4 MultiTech 2 HF Release Note

Elatec
Elatec TWN4 MULTITECH LEGIC M User manual

Elatec
Elatec TCP3 3.0.3.1 User manual

Elatec
Elatec TWN4 MultiTech 2 HF User manual

Elatec
Elatec TWN4 MultiTech 2 HF Use and care manual