GEN MENU
In the GENenrator menu, you can edit the jam
mode, edit the time and set an offset of the time
code output against the jammed time.
GEN > Ja TC
In the JamTC settings, you can select from
different jam behaviors:
Navigate toggling left/right, push to select.
“AUTO” – the ACL 204 will behave as used to from the former Lockit boxes. It will jam once
time code is detected, but not re-jam while time code is continuously present. As long as
time code is present, the “I” mark disappears to indicate that the unit is not ready to re-jam.
If the time code is disconnected for 3 or more seconds, the “I” reappears to indicate that the
unit will jam again once time code is received.
“OFF” – the ACL 204 does not jam to external time ode. This setting is useful if you set the
unit manually or via ACN and want to transmit an incoming time code value (for instance
from a device in record-run mode) at record start to the ACN Master unit.
“manual/once” – the ACL 204 jams once to external time code, but then will not jam again
but close the jam port. Once jammed, the “I” indicator disappears, signaling that the unit can
not be jammed from outside. This setting is useful if you want the unit to be jammed from
external time code but then not to be changed by incoming signal anymore, to transmit an
incoming time code value (for instance from a device in record-run mode) at record start to
the ACN Master unit. Also can be used should a Lockit box be used to re-jam cameras in
intervals and using a bi-directional time code cable, which would, with some cameras that
put out time code permanently even in “ext. TC” mode like the Alexa, lead to resetting the
ACL 204 in “AUTO” mode. To reactivate the jam port, just push the config switch repeatedly
going >GEN>JamTC>manual/once> and exit. The “I” indicator appears again, the unit is ready
to be jammed once again.
CAUTION! Resetting the generator will restart the video or audio sync signal, doing this
while recording will result in a corrupted file.

GEN>EDIT
CAUTION! Resetting the generator will restart the video or audio sync signal, doing this
while recording will result in a corrupted file.
GEN>OFFSET

SYNC MENU
SYNC>VIDEO
NTSC (480i), PAL (576i), 720p, 1080i, 1080p, 1080PsF
23.976, 24, 25, 29.97, 30, 50, 59.97, 60

There is no way out of this loop with an
invalid co bination!
Note: Any co bination of a “PAL-Area” video reference signal with an non-integer ti e
code (23.976 fps, 29.97 fps) or a ”NTSC-Area” video reference signal with an integer ti e
code (24 fps, 25 fps, 30 fps) is considered invalid as they will drift against each other and it
is not possible to provide a reference signal locked to the ti e code.
CAUTION! Resetting the generator will restart the video or audio sync signal, doing this
while recording will result in a corrupted file.

11
www.ambient.de
SYNC>AUDIO
Pushing the config switch while AUDIO is
highlighted takes you to the audio sync settings.
The curser is on the signal type selection. Change
by toggling left/right.
Select by pushing the config switch.
Types available: Wordclock, Black Audio (AES3)
Pushing the config switch selects and takes you to the rates setting.
Sample rates available: 32 KHz, 44.1 KHz, 48 KHz, 88.2 KHz, 96 KHz, 176.4 KHz, 192 KHz and
their respective pull-up / pull-down rates.
SYNC>OFF
The FPGA chip is powered off, no sync signal is
generated. Use this in time code only applications
to save battery life. You will be asked to confirm
by navigating the curser to “new”.
TC MENU
Enter the TC menu to adjust the time code frame
rate.
Adjust by toggling the config switch left/right,
push in to select new frame rate:
Rates: 23.976, 24, 25, 29.97, 30, 29.97D, 30D fps
(D = drop fra e)
If settings are changed, confirmation is required:
Pushing the config switch while “old” is
highlighted, discards the changes and returnsto
the main menu.
Pushing the config switch while “new” is
highlighted will set the time code signal to the selected rate.

There is no way out of this loop with an
invalid co bination!
SYS MENU
SYS>CONFIG
SYS>CONFIG>DISPLAY

13
www.ambient.de
Select after what time the display shuts off after
entering the main operation display.
Choices are:
Never – seconds – 30 seconds – 1 minute – minutes
Select by toggling the config switch left/right. Push in to select value.
SYS>CONFIG>BNC
Determine the output impedance for the video
sync signal:
Single: 7 Ohms for connecting to one video camera’s genlock input.
Dual/3D: 37. Ohms for splitting to two cameras’ genlock input.
Select by toggling the config switch left/right. Push in to select mode.
SYS>INFO
Select INFO to display information about the
ACL204:
Serial Number
Main firmware version
FPGA firmware version
ACN MENU
The ACN menu accesses the Ambient Clockit
Network configuration.

EXIT

8. LED Indications
This is the nor al operation ode.
9. Fir ware Update

16
www.ambient.de
10. Physical specifications
Dimensions: (L / W / H): 100 x 74 x 36 mm
Weight: 0.2 Kg (no batteries)
Power consumption: 90 mA (3 Volts, typical)
Connectors:
“A”: Lemo series 0B -pin (matching connector FGG/JGG.0B.30 .CLADxx)
pin 1: ground
pin 2: LTC IN
pin 3: ASCII IN / OUT
pin 4: Tune reference 1.92 MHz out / DC-IN to 18 Volts
pin : LTC OUT
“B”: Lemo series 0B -pin (matching connector FGG/JGG.0B.30 .CLADxx)
pin 1: ground
pin 2: LTC IN
pin 3: ACN / RS232 TX
pin 4: ACN / RS232 RX
pin : LTC OUT / 3.3 Volts DC OUT
SYNC: BNC coax 7 Ohms / 2x 7 Ohms parallel selectable
Antenna: SMA-F
USB: Mini-B -pin

11.
Warranty & Approvals
Warranty

CE Confor ity State ent:
FCC State ent
Other manuals for ACL 204
2
Other Ambient Inverter manuals
Popular Inverter manuals by other brands

Deye
Deye SUN-3K-G03 user manual

Crafstman
Crafstman 580.327182 Operator's manual

Whistler Group
Whistler Group XP1200i owner's manual

Scheppach
Scheppach SG1200 Translation from the original instruction manual

Cobra
Cobra CPI 1575 operating instructions

PrimeVOLT
PrimeVOLT PV-5000T-U Installation & operation manual

INVT
INVT Goodrive30 VFD Series Operation manual

ring
ring PowerSourcePure Series instruction manual

ECTIVE
ECTIVE MI Series Installation and operating instructions

RIPEnergy
RIPEnergy Mistral PS-150 user manual

Huawei
Huawei SUN2000 12K-MB0 quick guide

socomec
socomec SUNSYS pro Series Installation and operating manual