AMD Opteron 200 series User manual

User Manual
for
4U Server Blade
(Opteron™ 800MHz Hyper Transport Bus)
Aug. 2005 (Revision B)
P/N: 1230B0015201

C
Co
op
py
yr
ri
ig
gh
ht
t
N
No
ot
ti
ic
ce
e
The copyright in all material provided in this User Manual is held by Inventec Enterprise System
Corporation (IESC) or by the original creator of the material. Except as stated herein, none of the
material may be copied, reproduced, distributed, republished, downloaded, displayed, posted or
transmitted in any form or by any means, including, but not limited to, electronic, mechanical,
photocopying, recording, or otherwise, without the prior written permission of IESC. or the copyright
owner. Permission is granted to display, copy, distribute and download the materials in this User
Manual for personal, non-commercial use only, provided you do not modify the materials and that you
retain all copyright and other proprietary notices contained in the materials. You also may not, without
IESC’s permission, "mirror" any material contained in this Use Manual on any other server. This
permission terminates automatically if you breach any of these terms or conditions. Upon termination,
you must immediately destroy any printed materials. Any unauthorized use of any material contained
in this User Manual may violate copyright laws, trademark laws, the laws of privacy and publicity,
and communications regulations and statutes.

T
Tr
ra
ad
de
em
ma
ar
rk
ks
s
BroadCom®, the logos are registered trademarks of BroadCom Corporation and/or its subsidiaries in
the United States and certain other countries. All other trademarks are the property of their respective
owners.
AMD®Opteron™ is U.S. registered trademarks of AMD Corporation.
Linux is a registered trademark of Linus Torvalds.
Microsoft®and Windows NT®are U.S. registered trademarks of Microsoft Corporation.
Red Hat is a registered trademark and logos are trademarks or registered trademarks of Red Hat Inc. in
the United States and other countries.
The information in this document is provided “as is” without warranty of any kind and is subject to
change without notice. The warranties for Blade Server are set forth in the express limited warranty
statements accompanying such products. Nothing herein should be construed as constituting an
additional warranty.
.
This User Manual is subject to change without notice.
All brands and names are property of their respective owners.
Inventec Enterprise System Corp., 2005

C
Co
on
nt
te
en
nt
ts
s
About This Manual ........................................................................................................................................i
Conventions..................................................................................................................................................i
Package Contents ........................................................................................................................................ii
Safety and Regulatory Information............................................................................................................iii
Regulatory Compliance Identification Numbers....................................................................................iii
1Product Introduction .........................................................................................................................1-1
1.1 Product Features...........................................................................................................................1-2
1.2 Server Blade Layout.....................................................................................................................1-3
1.2.1 Opteron™ 200 series Server Blade Overview......................................................................1-3
1.3 Front panel....................................................................................................................................1-4
2Hardware Operation..........................................................................................................................2-1
2.1 Before You Start...........................................................................................................................2-1
2.1.1 Power Off.............................................................................................................................2-1
2.2 Battery..........................................................................................................................................2-2
2.2.1 To install the battery.............................................................................................................2-3
2.2.2 To remove the battery...........................................................................................................2-3
2.3 Processor ......................................................................................................................................2-4
2.3.1 To install the processor.........................................................................................................2-5
2.3.2 To install the heat sink..........................................................................................................2-6
2.3.3 To remove the processor and heat sink.................................................................................2-7
2.4 System Memory ...........................................................................................................................2-8
2.4.1 To install a DIMM................................................................................................................2-9
2.4.2 To remove a DIMM..............................................................................................................2-9
2.5 HDD...........................................................................................................................................2-10
2.5.1 To install the HDD .............................................................................................................2-10
2.5.2 To remove the HDD ...........................................................................................................2-11
2.6 PMC Card (Option)....................................................................................................................2-12
2.6.1 To install the PMC Card.....................................................................................................2-12
2.6.2 To remove the PMC Card...................................................................................................2-13
2.7 System Configuration Switch.....................................................................................................2-14
2.8 Server Blade...............................................................................................................................2-15
2.8.1 To Install and Remove the Server Blade............................................................................2-15
3BIOS Setup .........................................................................................................................................3-1
3.1 BIOS Setup Utility.......................................................................................................................3-1
3.2 Entering the BIOS Setup Utility...................................................................................................3-2
3.3 Keyboard Command Bar..............................................................................................................3-3
3.4 BIOS Updates...............................................................................................................................3-5
3.4.1 BIOS Requirements..............................................................................................................3-5
3.4.2 ROM Flash...........................................................................................................................3-5
3.5 Blade BMC Updates.....................................................................................................................3-6

3.6 Champs BMC Updates.................................................................................................................3-6
4Diagnostic Tools Utility Overview.....................................................................................................4-1
L
Li
is
st
t
o
of
f
F
Fi
ig
gu
ur
re
es
s
Figure 1-1 Opteron™ 200 series Server Blade Overview.................................................................1-1
Figure 1-2 Opteron™ 200 series Server Blade Component Locations.............................................1-3
Figure 1-3 Server Blade Front Panel Component Locations.............................................................1-4
Figure 2-1 Powering off the server blade..........................................................................................2-1
Figure 2-2 Battery Location..............................................................................................................2-2
Figure 2-3 Putting the battery into the holder ...................................................................................2-3
Figure 2-4 Pulling the battery out of the holder ................................................................................2-3
Figure 2-5 Processor Location ..........................................................................................................2-4
Figure 2-6 Pressing the locking lever down......................................................................................2-5
Figure 2-7 Heat Sink and Sponge Location ......................................................................................2-6
Figure 2-8 Putting down the heat sink...............................................................................................2-6
Figure 2-9 Rotating the fasteners to fit the heat sink.........................................................................2-6
Figure 2-10 System Memory Location..............................................................................................2-9
Figure 2-11 Inserting the DIMM into the socket...............................................................................2-9
Figure 2-12 Lifting the DIMM out of the socket...............................................................................2-9
Figure 2-13 HDD Location .............................................................................................................2-10
Figure 2-14 Locating the HDD to the HDD tray.............................................................................2-10
Figure 2-15 Installing the HDD.......................................................................................................2-11
Figure 2-16 Pressing the HDD release buttons ...............................................................................2-11
Figure 2-17 Lifting the HDD from the server blade........................................................................2-11
Figure 2-18 PMC Card Location.....................................................................................................2-12
Figure 2-19 Locating the bezels with the screws ............................................................................2-12
Figure 2-20 Installing the PMC card...............................................................................................2-12
Figure 2-21 Securing the PMC card to the blade ............................................................................2-13
Figure 2-22 Server Blade Board Switch Location...........................................................................2-14
Figure 2-23 Server Blade Location .................................................................................................2-15
Figure 2-24 Sliding the server blade fully into the bay...................................................................2-15
Figure 2-25 Pressing the release button...........................................................................................2-15
Figure 2-26 Removing the server blade ..........................................................................................2-16
L
Li
is
st
t
o
of
f
T
Ta
ab
bl
le
es
s
Table 1-1 Front Panel LED Status.....................................................................................................1-4
Table 2-1 DIMM Installation Option 1 .............................................................................................2-8
Table 2-2 DIMM Installation Option 2 .............................................................................................2-8
Table 2-3 Server Blade Board Switch .............................................................................................2-14
Table 3-1 BIOS Setup Utility Screen Description.............................................................................3-2
Table 3-2 Keyboard Command Bar Description...............................................................................3-4
Table 3-3 BIOS Requirements Description.......................................................................................3-5
Table 4-1 Diagnostic Tools................................................................................................................4-1

This chapter provides the safety
and regulatory information of Serve
r
Blade.
About This Manual
About This Manual

1230B0015201 About This Manual i
A
Ab
bo
ou
ut
t
T
Th
hi
is
s
M
Ma
an
nu
ua
al
l
This guide provides step-by-step instructions for the installation and maintenance information of
Blade Server.
This guide is presented for service technicians of computer equipment. Blade Server supplier assumes
that you are network administrators or IT personnel who are qualified in installing, configuring,
maintaining and servicing system hardware and software.
C
Co
on
nv
ve
en
nt
ti
io
on
ns
s
To make sure that you perform certain tasks properly, take note of the following symbols used
throughout this manual.
Warning: Information to prevent injury to yourself when trying to complete a task.
Caution: Information to prevent damage to the components when trying to complete
a task.
Important: Information that you must follow to complete a task.
Note: Tips and information to aid in completing a task.

1230B0015201 About This Manual ii
P
Pa
ac
ck
ka
ag
ge
e
C
Co
on
nt
te
en
nt
ts
s
This section lists the items included in the server package.
Blade Unit Part List
* Not available now, will support in future.
Reference Document
Item Description
1 User Manual for 4U Blade Server Chassis (Opteron™ 800MHz
Hyper Transport Bus)
Item Description
1 AMD®Opteron™ 200 series Server Blade
2 PMC Card (Option)
3 AMD®Opteron™ 200 series Processor with Heat Sink (800MHz
Hyper Transport Bus)
4 2.5” SATA HDD 40GB/60GB
5 Very low profile DDR1-400 ECC Registered DIMM
512MB/1G/2G (Option)
6 Mini-backplane Kit*
7 COM Port Cable

1230B0015201 About This Manual iii
S
Sa
af
fe
et
ty
y
a
an
nd
d
R
Re
eg
gu
ul
la
at
to
or
ry
y
I
In
nf
fo
or
rm
ma
at
ti
io
on
n
Regulatory Compliance Identification Numbers
For the purpose of regulatory compliance certifications and identification, this server is assigned a
series number. This server series number can be found on the product label, along with the required
approval markings and information. When requesting certification information for this product, always
refer to this series number. This series number should not be confused with the marketing name or
model number.
Federal Communications Commission Notice
This equipment has been tested and found to comply with the limits for a Class A digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference when the equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio communications. Operation
of this equipment in a residential area is likely to cause harmful interference, in which case the user
will be required to correct the interference at personal expense.
Modifications
The FCC requires the user to be noticed that any changes or modifications made to this device that are
not expressly approved by the supplier may invalidate the user’s authority to operate the equipment.
Battery Replacement Notice
Your computer is provided with an internal lithium battery or battery pack. There is a danger of
explosion and risk of personal injury if the battery is incorrectly replaced or mistreated. Unless
specific replacement instructions are provided as part of this guide, replacement is to be done by an
authorized service provider using the parts designated for this product.
For more information about battery replacement or proper disposal, contact an authorized reseller or
authorized service provider.

1230B0015201 About This Manual iv
Warning: Your computer contains an internal lithium manganese dioxide, a vanadium
pentoxide, or an alkaline battery pack. There is risk of fire and burns if the battery pack is
not handled properly. To reduce the risk of personal injury,
Do not attempt to recharge the battery.
Do not expose to temperatures higher than 60°C.
Do not disassemble, crush, puncture, short external contacts, or dispose of in fire or
water.
Replace only with the spare parts designated for this product.
Batteries, battery packs, and accumulators should not be disposed of together with the general
household waste. To forward them to recycling or proper disposal, please use the public collection
system or return them to the supplier, the supplier’s authorized partners, or their agents.

Product Introduction
This chapter describes the general
product introduction information o
f
the Server Blade.
Chapter 1
Product Introduction

1230B0015201 Product Introduction 1-1
1
1
P
Pr
ro
od
du
uc
ct
t
I
In
nt
tr
ro
od
du
uc
ct
ti
io
on
n
This chapter provides the detailed features for battery, processor, system memory, HDD, system
configuration switch with pictures for your reference.
AMD®Opteron™ 200 series Server Blade Overview
Figure 1-1 Opteron™ 200 series Server Blade Overview

1230B0015201 Product Introduction 1-2
1
1.
.1
1
P
Pr
ro
od
du
uc
ct
t
F
Fe
ea
at
tu
ur
re
es
s
This server blade uses serverwork HT-2000, HT-1000 chipset. The server blade supports dual AMD®
Opteron™ 200 series processors with 800MHz Hyper Transport Bus to accelerate even the most
complicated server tasks. AMD®Opteron™ 200 series processor based blades are designed to meet
the needs of the most demanding applications. Sensors on each ATCA processor monitor temperature
and voltage alerting system before problems occur.
The supplier’s blades are hot pluggable and can be powered on/off and reset remotely. The following
highlights are the server’s main features. For additional information, refer to this user manual.
Processor: AMD® Opteron™ 200 series processor with 800MHz Hyper Transport Bus.
System Memory: Four straight very low profile DIMM sockets that support up to 8 GB of
registered DDR1-400 with ECC support.
Storage: Support one 2.5” SATA HDD.
PMC/XMC interface option : use the same location as SATA HDD, XMC card is still not
available for test.

1230B0015201 Product Introduction 1-3
1
1.
.2
2
S
Se
er
rv
ve
er
r
B
Bl
la
ad
de
e
L
La
ay
yo
ou
ut
t
The layout of the server blade is shown as below. Each connector and major component is identified
by the number.
1.2.1 Opteron™ 200 series Server Blade Overview
Figure 1-2 Opteron™ 200 series Server Blade Component Locations
DIMM Socket 1B System Battery
DIMM Socket 1A Configuration Switch
Processor 1 DIMM Socket 2A
Processor 2 DIMM Socket 2B
PMC Card Connector Mini-backplane Connector
2.5 inch SATA HDD Middle Plane Connector
Handle

1230B0015201 Product Introduction 1-4
1
1.
.3
3
F
Fr
ro
on
nt
t
p
pa
an
ne
el
l
Figure 1-3 Server Blade Front Panel Component Locations
Item Function Color Status
Green Power On
Power Switch / LED Red Power Off
Green On: Link / Active
Blade Switch LED Off: No Link
COM Port
USB Connector 1
USB Connector 2
Green On: Link / Active
NIC1 Status Off: No Link
Green On: Link / Active
NIC2 Status Off: No Link
Green On: Active
Disk Active Off: Inactive
Green Normal
Red Critical
System Health
Amber Warning
On *
Long Blinking *
Blue
Short Blinking *
UID
Off *
Table 1-1 Front Panel LED Status
* User can use CLI to change the light function.

Hardware Operation
This chapter provides step-by-step
instructions for installation and
hardware information for this Serve
r
Blade.
Chapter 2
Hardware Operation

1230B0015201 Hardware Operation 2-1
2
2
H
Ha
ar
rd
dw
wa
ar
re
e
O
Op
pe
er
ra
at
ti
io
on
n
This chapter provides the detailed information and installing steps for Server Blade, including Battery,
HDD, Processor, System Memory, and System Configuration Switch.
2
2.
.1
1
B
Be
ef
fo
or
re
e
Y
Yo
ou
u
S
St
ta
ar
rt
t
Take note of the following operations before you start to install or remove any internal components.
2.1.1 Power Off
The server does not completely power off when the front panel power button is pressed. The button
toggles server power between On and Standby. In Standby mode, the server removes power from most
electronics and drives, but portions of the power supply and some internal circuitry remain active. To
completely remove all power from the system, disconnect the power cord from the server.
Power off the Server Blade
Press the power button to power off the
server blade and make sure the power LED
changes from green to red.
Figure 2-1 Powering off the server blade
To power off the server, please refer to “2.1.1 Power Off” in the Chassis User Manual.
Warning: To reduce the risk of injury from electric shock, remove the power cord to
completely disconnect power from the system.
Caution: Electrostatic discharge (ESD) can damage electronic components. Be sure you
are properly grounded before starting any installation procedure. For more information, see
“Electrostatic Discharge Information” in “About This Manual” of Chassis User Manual.

1230B0015201 Hardware Operation 2-2
2
2.
.2
2
B
Ba
at
tt
te
er
ry
y
If the server no longer automatically displays the correct date and time, check the battery that provides
power to the real time clock. If necessary, replace the old battery with a CR2032 lithium battery.
Under normal use, battery life is at least 5 years.
The location of battery is shown as below:
Figure 2-2 Battery Location
Caution: Loss of BIOS settings occurs when the battery is removed. BIOS settings must
be reconfigured whenever the battery is replaced.
Caution: Batteries, battery packs, and accumulators should not be disposed of together
with general household waste. Use the public collection system or return used batteries to
your authorized partners or their agents for proper recycling and disposal.
Important: Before you install or remove the battery, please see “2.1 Before You Start”.
Warning: This server contains either an internal lithium manganese dioxide, or a
vanadium pent oxide battery. There is a risk of fire and burns if the battery pack is not
handled properly. To reduce the risk of personal injury:
Do not attempt to recharge.
Do not expose to temperatures higher than 60°C (140°F).
Do not disassemble, crush, puncture, short external contacts, or dispose of in fire or
water.
Replace only with the spare designated for this product.

1230B0015201 Hardware Operation 2-3
2.2.1 To install the battery
Pull the battery retaining clip away.
Put the battery into the holder until it fits
the space completely.
Figure 2-3 Putting the battery into the holder
2.2.2 To remove the battery
Pull the battery retaining clip away from
the battery.
Lift the battery out of the holder.
Figure 2-4 Pulling the battery out of the holder
Important: Do not bend the retaining clip during battery replacement. For proper
operation, the clip must maintain a position of contact with the battery.

1230B0015201 Hardware Operation 2-4
2
2.
.3
3
P
Pr
ro
oc
ce
es
ss
so
or
r
The server blade uses AMD®Opteron™ 200 series processors in 940-pin mPGA sockets with
800MHz Hyper Transport Bus.
The location of the processor on the motherboard is shown as below:
Figure 2-5 Processor Location
Processor 1
Processor 2
You can install single or dual processors on the board according to your own needs. Please refer to the
following points before the installation:
1. If SINGLE processor is intended, always install the processor on the processor 1 socket and for the
location of processor 1 and processor 2, please refer to the above figure.
2. If install DUAL processors, you must install processor 1 first and use the same type of processor
running at the same identical revision, core voltage and bus/core speed.
Important: Before you install or remove the processor, please see “2.1 Before You
Start”.
Important: Processor module contains the heat sink and the processor. To remove the
Processor module, please remove the heat sink first, then, remove the processor from the
system board.
Table of contents