Model Numbers
AD100XA . . . . . . . . . . . . . . . . . . . . . . . . Recorder Controller, 120 VAC, 60 Hz
AD100XA-1A . . . . . . . . . . . . . . . . . . . . . Recorder Controller, 230 VAC, 50/60 Hz
AD100IR16 . . . . . . . . . . . . . . . . . . . . . . IR Interface Module, 120 VAC, 60 Hz
AD100IR16-1A . . . . . . . . . . . . . . . . . . . IR Interface Module, 230 VAC, 50/60 Hz
AD100RL8 . . . . . . . . . . . . . . . . . . . . . . . Resistive Ladder Interface Module,
120 VAC, 60 Hz
AD100RL8-1 . . . . . . . . . . . . . . . . . . . . . Resistive Ladder Interface Module,
230 VAC, 50/60 Hz
AD100RS8 . . . . . . . . . . . . . . . . . . . . . . .RS-232 Interface Module,
120 VAC, 60 Hz
AD100RS8-1 . . . . . . . . . . . . . . . . . . . . . RS-232 Interface Module,
230 VAC, 50/60 Hz
Note: AC wall-type transformer supplied (9 VAC for 120 V, 8-9 VAC for 230 V).
Electrical
Input Voltage
AD100XA, AD100IR16,
AD100RL8, AD100RS8 . . . . . . . . . . 120 VAC, 60 Hz
AD100XA-1A, AD100IR16-1A,
AD100RL8-1, AD100RS8-1 . . . . . . 230 VAC, 50/60 Hz
Power Consumption
AD100XA . . . . . . . . . . . . . . . . . . . . . . 3.0 watts (nominal)
AD100IR16, AD100RS8 Series,
AD100RL8 Series . . . . . . . . . . . . . . . . 2.0 watts (nominal)
Drive Capability for AD100XA Series
Max RS-485 Distance . . . . . . . . . . . . 1,220 m (4,000 ft)
Max Number RS-485 Loads . . . . . . 24 loads
Mechanical
Mounting . . . . . . . . . . . . . . . . . . . . . . . Desktop, wall or rack mount
Dimensions (H x W x D)
AD100XA, AD100RS8 Series . . . . . 3.5 x 9.5 x 16.61 cm
(1.38 x 3.75 x 6.50 in)
AD100IR16, AD100RL8 Series . . . 3.5 x 8.3 x 13.97 cm
(1.38 x 3.25 x 5.50 in)
Unit Weight
AD100XA, AD100RS8 Series . . . . . 0.25 kg (9.0 oz)
AD100IR16, AD100RL8 Series . . . 0.20 kg (7.0 oz)
Color (Plastic Housing) . . . . . . . . . . . Black
Environmental
Operating Temperature . . . . . . . . . . . 5° to 40° C (40° to 104° F)
Humidity . . . . . . . . . . . . . . . . . . . . . . . . 95% RH (non-condensing)
Storage Temperature . . . . . . . . . . . . . -40° to 70° C (-40° to 155° F)
Regulatory
Emissions . . . . . . . . . . . . . . . . . . . . . . . FCC: Part 15,
Subpart B, Class A
CE: EN55022, Class B
Immunity . . . . . . . . . . . . . . . . . . . . . . . CE: EN50130-4
Safety
AD100XA-1A, AD100IR16-1A, AD100RL8-1,
AD100RS8-1 Series . . . . . . . . . . . . . . CE: EN60950
Accessories
AD100IRE . . . . . . . . . . . . . . . . . . . . . . . 3.05 m (10 ft) IR Emitter Cable
(connects the IR Interface Module
and the IR recorder); one required
for every IR recorder
AD100RLW . . . . . . . . . . . . . . . . . . . . . . 3.05 m (10 ft) Resistive Ladder Cable
(connects the Resistive Ladder
Interface Module and the resistive
ladder recorder); one required
forevery resistive ladder recorder
AD100RSC . . . . . . . . . . . . . . . . . . . . . . 3.05 m (10 ft) RS-232 Cable
(connects the RS-232 Interface
Module and the RS-232 recorder);
one required for every RS-232
recorder
AMERICAN DYNAMICS AD100 RECORDER CONTROL DEVICES