FEATURES
The AD2091 Series Manchester Control Code
Generator/Distributor provides economical
distribution of AD Manchester code to SpeedDome®
Ultra Series Domes, SpeedDome Optima Series
Domes and compatible receiver/drivers. The
AD2091 interfaces with the MegaPower™1024 or 168
via high speed data line. The AD2091 provides up to
64 independent buffered AD Manchester Control
Code outputs in four groups of 16. Each group is
capable of controlling separate blocks of 64 camera
sites. Multiple units can be cascaded to provide
control for up to 1024 camera sites. Each output
will drive up to 5000 ft. of cable. Alternatively. A
single RS-232 output, with selectable baud rates may
be used for transmitting code over suitably equipped
devices. The AD2091 can also be used to combine
control code from two different matrix systems. The
unit can be mounted in a rack or on a wall surface.
The AD1691 Series Manchester Control Code
Distributor provides economical distribution of AD
Manchester code to SpeedDome Ultra Series Domes,
SpeedDome Optima Series Domes and compatible
receiver/drivers. The AD1691 interfaces with the
matrix systems and other accessories via a single
Manchester input. The AD1691 provides up to 64
independent buffered AD Manchester Control Code
outputs. The unit can be mounted on a wall surface.
The AD1691 provides a simple solution for receiving
a single Manchester connection from a remote
location and then distributing it through a facility.
AD1691 &
AD2091 Series
MANCHESTER DISTRIBUTOR ACCESSORIES
AD2091 Series Manchester
Control Code
•Generator/Distributor
•64 Manchester outputs in
four groups of 16
•One RS-232 output
•Can be used as a code
combiner
•Diagnostic LEDs
•Universal wall, surface or
rack mount
•Quick-connect screw
terminals for all cable
connections
AD1691 Manchester
•Control Code Distributor
•64 Manchester outputs
•Ideal for distributing
Manchester code
•Surface mount design
www.americandynamics.net
Front side – Single sheet – Letter size – print 4/c
AD2091
AD1691
AD2091_AD1691_VS234_L.qxd 2/25/04 7:47 AM Page 1
SPECIFICATIONS
Model Numbers
AD2091 . . . . . . . . . . . . . . . . . . . .Manchester Control Code
Generator/distributor, 120 VAC
AD2091-1 . . . . . . . . . . . . . . . . . .Manchester Control Code
Generator/distributor, 230 VAC
Operational
Dome/Receiver Outputs . . . . .64 Manchester outputs, 4 groups of 16
outputs
Address Range . . . . . . . . . . . . . .1 to 1024 in blocks of 64 per group
LEDs . . . . . . . . . . . . . . . . . . . . . .3 (power, HSDL 1 and 2)
Connectors
High Speed Data Line . . . . . . .BNC, in and out (HSDL 1)
BNC, in and out (HSDL 2)
RS-232 . . . . . . . . . . . . . . . . . . . . .RJ-45
Manchester Control Code . . .Sixteen 12 pin removable screw terminal
Electrical
Supply Voltage
AD2091 . . . . . . . . . . . . . . . . .120 VAC, 50/60 Hz
AD2091-1 . . . . . . . . . . . . . . . .230 VAC, 50/60 Hz
Power Consumption . . . . . . . .8 Watts nominal
Mechanical
Dimensions (H x W x D) . . . . .89 x 432 x 203 mm
(3.5 x 17.0 x 8.0 in)
Unit Weight . . . . . . . . . . . . . . . .3.2 kg (7.0 lbs)
Shipping Weight . . . . . . . . . . . .4.1 kg (9.0 lbs)
Mounting . . . . . . . . . . . . . . . . . .Universal wall, surface and rack
(19-inch EIA)
Environmental
Operating Temperature . . . . .0° to 40° C (32° to 104 F)
Humidity . . . . . . . . . . . . . . . . . .98% RH (non-condensing)
Storage Temperature . . . . . . . .-40° to 70° C (-40° to 155° F)
Regulatory
Emissions . . . . . . . . . . . . . . . . . .FCC Part 15, Subpart B, Class A
CE: EN55022 Class B
Immunity . . . . . . . . . . . . . . . . . .CE: EN50082-1
Safety . . . . . . . . . . . . . . . . . . . . . .UL2044
cUL: CSA C22.2 No. 1-94
CE: EN60950
Model Numbers
AD1691 . . . . . . . . . . . . . . . . . . . .Manchester Control Code Distributor,
120 VAC
AD1691F-1 . . . . . . . . . . . . . . . . .Manchester Control Code Distributor,
24 VAC
Operational
Dome/Receiver Outputs . . . . .64 Manchester outputs
Address Range . . . . . . . . . . . . . .1 to 1024 in blocks of 64
LEDs . . . . . . . . . . . . . . . . . . . . . .Three (power, HSDL 1 and 2)
Connectors
Inputs
Manchester Control
Code . . . . . . . . . . . . . . . . . . .Six pin Euro style screw terminal connector
Outputs
Manchester Control
Code . . . . . . . . . . . . . . . . . . .64 stake on connectors
Electrical
Supply Voltage
AD1691 . . . . . . . . . . . . . . . . .120 VAC, 50/60 Hz
AD1691F-1 . . . . . . . . . . . . . .24 VAC, 50/60 Hz
Power Consumption . . . . . . . .Five watts, separate wall-type transformer
provided
Mechanical
Dimensions (H x W x D) . . . . .305 x 356 x 102 mm
(12.0 x 14.0 x 4.0 in)
Unit Weight . . . . . . . . . . . . . . . .4.5 kg (10.0 lbs)
Shipping Weight . . . . . . . . . . . .5.5 kg (12.1 lbs)
Mounting . . . . . . . . . . . . . . . . . .Surface mount
Environmental
Operating Temperature . . . . .0° to 40° C (32° to 104° F)
Humidity . . . . . . . . . . . . . . . . . .98% RH (non-condensing)
Storage Temperature . . . . . . . .-40° to 70° C (-40° to 155° F)
Regulatory
Emissions . . . . . . . . . . . . . . . . . .FCC Part 15, Subpart B, Class A
CE: EN55022 Class B
Immunity . . . . . . . . . . . . . . . . . .CE: EN50082-1
Safety . . . . . . . . . . . . . . . . . . . . . .UL2044
CUL: CSA C22.2 No. 1-94
CE: EN60950
AD1691 & AD2091 SERIES MANCHESTER DISRIBUTOR ACCESSORIES
Product specifications and availability subject to
change without notice.
Certain product names mentioned herein may be trade
names and/or registered trademarks of other companies.
VS234-01 08/03 L
©2003 Sensormatic Electronics Corporation
Back side – Single sheet – Letter size – print b/w
Typical AD2091 Connection Typical AD1691 Connection
AD2091_AD1691_VS234_L.qxd 2/25/04 7:47 AM Page 2

Other manuals for AD2091

2

This manual suits for next models

3

Other American Dynamics Recording Equipment manuals

American Dynamics AD168 User manual

American Dynamics

American Dynamics AD168 User manual

American Dynamics MP-KMI Manual

American Dynamics

American Dynamics MP-KMI Manual

American Dynamics AD100 User manual

American Dynamics

American Dynamics AD100 User manual

American Dynamics AD2083-02C User manual

American Dynamics

American Dynamics AD2083-02C User manual

Popular Recording Equipment manuals by other brands

JK Audio innkeeper LTD user guide

JK Audio

JK Audio innkeeper LTD user guide

Jupiter Avionics JA95-N42 Installation and operating manual

Jupiter Avionics

Jupiter Avionics JA95-N42 Installation and operating manual

Yamaha MBCL owner's manual

Yamaha

Yamaha MBCL owner's manual

Extron electronics XMP 240 C AT user guide

Extron electronics

Extron electronics XMP 240 C AT user guide

Future light ICL-6 user manual

Future light

Future light ICL-6 user manual

GRAPHTEC GL2000 quick start guide

GRAPHTEC

GRAPHTEC GL2000 quick start guide

NavLinkz VL6-PCM21-24P Specifications & installation

NavLinkz

NavLinkz VL6-PCM21-24P Specifications & installation

Extron electronics RGB 109xi Specifications

Extron electronics

Extron electronics RGB 109xi Specifications

RODE Microphones AI-1 Service manual

RODE Microphones

RODE Microphones AI-1 Service manual

Vocalist Live Harmony owner's manual

Vocalist

Vocalist Live Harmony owner's manual

Elan M86A installation manual

Elan

Elan M86A installation manual

JETI model Central Box 400 user manual

JETI model

JETI model Central Box 400 user manual

Sound Devices 722 User guide and technical information

Sound Devices

Sound Devices 722 User guide and technical information

Behringer 911A quick start guide

Behringer

Behringer 911A quick start guide

Korg EX-800 Service manual

Korg

Korg EX-800 Service manual

DITEC COM501HCV operating instructions

DITEC

DITEC COM501HCV operating instructions

Tascam DP-24SD owner's manual

Tascam

Tascam DP-24SD owner's manual

Crown IQ-RPT 3 Reference manual

Crown

Crown IQ-RPT 3 Reference manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.