Power
(On/O)
Slide Dimmer for
1-100% Brightness
Control
Zone 1-4
Scenes 1-3
SYNCING CONTROLLER TO RECEIVER (SEE FIGURES 3 & 4):
This controller requires a Radio Frequency receiver for
operation (REC-5A-4Z or REC-5A-4Z-WiFi sold separately).
1. Touch the power icon on the controller once to turn on power
to the controller.
2. Press the “Learning Key” on the receiver.
3. Select a zone by touching one of the four zone icons on the
controller, then touch the slide dimmer to activate controller.
4. Once successfully synced, the connected light source will blink.
5. Repeat steps 2-3 when syncing multiple receivers to a single
controller.
6. Press and hold the “Learning Key” to clear out saved sync data
when wanting to reset scenes or zones.
CARE AND MAINTENANCE:
1. For cleaning, use a soft, dry or damp cloth. Do not use harsh chemicals or abrasives.
Page 2 of 2 11775 E. 45th Ave. Denver, CO 80239 Ph: 1-800-880-1180 Fax: 303-695-7633
FIGURE 3
FIGURE 4
12-24V
INSTALLATION INSTRUCTIONS
SRF-4Z-3P
OPERATING CONTROLLER (SEE FIGURE 4):
This controller requires a 12-24V DC power supply
(LED-DR series driver sold separately).
1. Touch the power icon for On/O power control.
2. To adjust brightness, touch and slide the slide dimmer for 1-100%
brightness control.
3. To select a zone, touch the zone icon once. Memory can select
multiple zones simultaneously.
4. To turn a zone On or O, touch and hold zone icon for
2 seconds. The zone icon will turn Blue when ON and Yellow
when OFF.
5. To save a scene, determine desired settings, touch and hold
scene icon for 2 seconds. Memory will hold 3 scenes per zone.
6. To select a scene, touch one of the three scene icons once.
TRULUX RF Single-Color Touch Control
Touch-Sensitive Faceplate
SR-1009FA
LED CONTROLLER
INPUT
12-36V DC
PRI
SEC
Learning Key
MASTER SLAVE
CW
W
WW
B
CW
G
WW
R
° tc=75°C
150805V1
PRI:
Uin=12-36VDC
Iin=20.5A
SEC:
Uout=4x(12-36)VDC
Iout=4x5A
Pout=4x(60-180)W
TEMP RANGE:-20°C-+50°C
6-7mm
0.5-1.5mm2
Trulux RF Receiver
(sold separately)
To 12-24V DC
Power Supply
Learning Key
RF Controller “talks” to the receiver via a
wireless Radio Frequency (RF) signal
©2019 American Lighting, Inc. REV1913 www.AmericanLighting.com
FCC Compliance Statement
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
1. This device may not cause harmful interference, and
2. This device must accept any interference received, including interference that may cause undesired operation.
FCC WARNING
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy
and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by
turning the equipment o and on, the user is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and the receiver.
• Connect the equipment into an outlet dierent from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.