American Range AFCT-15 User manual

OWNER’S MANUAL FOR
COUNTERTOP FRYER
MODEL NUMBERS: AFCT-15
PROFESSIONAL QUALITY COOKING EQUIPMENT
13592 Desmond St., Pacoima, CA 91331 818.897.0808 tel 888.753.9898 toll free www.americanrange.com
DESIGN CLASS FUNCTION
© 2012 American Range
All Rights Reserved

Installation, Operation and
Maintenance Instructions
13592 Desmond St., Pacoima, CA 91331 818.897.0808 tel 888.753.9898 toll free www.americanrange.com
Countertop Fryer
Owner’s Manual
FOR YOUR SAFETY!
Do not store or use gasoline or
other ammable vapors or liquids
in the vicinity of this or any other appliance.
FOR
YOUR
SAFETY
FOR
YOUR
SAFETY
RETAIN THIS MANUAL FOR FUTURE REFERENCE.
WARNING!
Improper installation, adjustment, alteration, service
or maintenance can cause property damage, injury
or death and will void warranty. Read the
installation, operating and maintenance instructions
thoroughly before installing or servicing this equipment.
WARNING
IMPROPER
INSTALLATION
WARNING
IMPROPER
INSTALLATION
Model Number: __________________________________________
Serial Number: ___________________________________________
Purchase Date: ___________________________________________
Installed By: __________________________ Install Date:__________
Gas Type: _______________________________________________
Electrical Information: ______________________________________
This equipment is design engineered for commercial use only.
IMPORTANT SERVICE NOTICE!
Using any part other than genuine American Range factory supplied
parts relieves the manufacturer of all liability.
American Range reserves the right to change product design and
specications without notice. Such revisions do not entitle the buyer
to corresponding changes, improvements, additions or replacements
for the previously purchased equipment.
Instructions to be followed in the event the user smells gas should be posted
in a prominent location. This information should be obtained by
consulting the local gas supplier.

To Our Most Valued Customer:
Congratulations on your purchase of an American Range product. We hope you will enjoy the
design, manufactured quality, innovative features and cooking performance of this product – it
represents our continuing dedication to satisfying the most demanding needs of customers
like you.
Please read this manual and become familiar with important safety information about how
to install and set-up the unit, basic operating instructions, and how to maintain that just-like-
brand-new appearance and performance - over years of day-to-day use.
If you should encounter any sort of problem, turn to the section of the manual entitled,
“Troubleshooting” – for a quick solution or guidance regarding the next step required to get
back to tip-top condition.
Thank you for choosing an American Range product for your kitchen. As you can expect, this
appliance is designed for years of reliable service. If you have any questions or comments,
please contact the dealer from whom you purchased the unit, or contact American Range
Customer Service via email: info@americanrange.com at www.americanrange.com, or call
888.753.9898.
PROFESSIONAL QUALITY COOKING EQUIPMENT
13592 Desmond St., Pacoima, CA 91331 818.897.0808 tel 888.753.9898 toll free www.americanrange.com
Sincerely,
President, American Range Corporation
Shane Demirjian

13592 Desmond St., Pacoima, CA 91331 818.897.0808 tel 888.753.9898 toll free www.americanrange.com
Owner’s Manual Countertop Fryer
Table of Contents
GENERAL ...................................................................................................1-3
General Information ..............................................................................................1
About This Manual.................................................................................................. 2
Shipping Damage Claim Procedure.............................................................. 3
Rating Plate .................................................................................................................3
Clearances...................................................................................................................3
INSTALLATION ........................................................................................4-7
Gas Utility Connections-Standards & Codes.......................................... 4
Instructions..................................................................................................................4
Fryers with Casters................................................................................................4
Wiring Diagram........................................................................................................5
Models and Parts Identication.......................................................................6
Installation Checklist...............................................................................................7
OPERATING ..............................................................................................8-9
Before Turning Burner On.................................................................................. 8
Lighting ..........................................................................................................................8
Frying with Shortening.........................................................................................8
Cleaning ........................................................................................................................9
EXPLODED VIEW DRAWINGS/PARTS LISTS ............................. 10-11
TROUBLESHOOTING ............................................................................. 12

13592 Desmond St., Pacoima, CA 91331 818.897.0808 tel 888.753.9898 toll free www.americanrange.com
1
Owner’s Manual Countertop Fryer
WARNING
If the information in this manual is not followed exactly, a re or
explosion may result causing damage, personal injury or death.
• INSTALLATION AND SERVICE MUST BE PERFORMED BY A
CERTIFIED / LICENSED INSTALLER, SERVICE AGENCY OR THE GAS SUPPLIER
• Do not store or use gasoline or other ammable vapors or liquids in the vicinity
of this or any other appliance.
• Please observe all local and national codes and ordinances.
• Do not remove any permanent warning labels or plates from this product.
• Consumers should retain these instructions for local inspectors and for
future use.
• WHAT TO DO IF YOU SMELL GAS
º Do not try to light any appliance.
º Do not touch any electrical switch, do not use any phone in your building.
º Immediately call your gas company. Follow the gas supplier instructions.
º If you cannot reach your gas supplier, call the Fire Department.
WARRANTY REQUIREMENT
For reliable operation and for your own safety, this professional cooking equipment
must be installed by a certied/licensed contractor.
Failure to comply will void any written or implied warranty.
Should the equipment require service during the standard warranty period, the
receipt proving certied installation must be made available to American Range for
verication.
If installation was not performed by a certied/licensed contractor be prepared to
submit a major credit card for payment for proper installation.

13592 Desmond St., Pacoima, CA 91331 818.897.0808 tel 888.753.9898 toll free www.americanrange.com
2
Owner’s Manual Countertop Fryer
The Use and Care Manual is divided into several sections:
The Safety Section informs you about signicant safety precautions when installing and operating your
new fryer. This is a must read section of the manual.
Quick Start and Installation Section describes how to unpack the unit, what to save and what to discard,
installation dimensions, gas and electrical connections and how to identify the primary parts of the
product so you can better understand what’s going on “under the hood”.
How to Use Your Product shows you how to light the pilot and set frying temperatures.
The Care and Maintenance and Troubleshooting and Service Sections discuss how to keep your product
in good operating condition, how to identify what might be going wrong with the unit, and how to
communicate your observations with authorized eld service technicians.
Before using your appliance, please read this manual paying special attention to the important safety
instructions located in the next several pages.
ABOUT THIS MANUAL
!
DANGER
!
CAUTION
!
This is the SAFETY ALERT SYMBOL. This symbol alerts
you to hazards which will result in severe injury or death.
Hazards or unsafe practices which will result in severe
personal injury or death.
Hazards or unsafe practices which may result in minor
personal injury or property damage.
WARNING
!Hazards or unsafe practices which may result in severe
personal injury or death.
CALIFORNIA PROPOSITION 65 WARNING
The burning of gas cooking fuel generates some by-products which are on the list of substances known by the State of
California to cause cancer or reproductive harm. California law requires businesses to warn customers of potential exposure
to such substances. To minimize exposure to these substances, always operate this unit according to the Owners Manual,
ensuring you provide proper ventilation when cooking with gas.

Owner’s Manual Countertop Fryer
13592 Desmond St., Pacoima, CA 91331 818.897.0808 tel 888.753.9898 toll free www.americanrange.com
3
• Before beginning, please read all the instructions carefully.
• DO NOT remove permanently afxed labels, warnings, or plates from product. This will void the warranty.
• All local and national codes and ordinances must be observed; installation must conform with local codes.
• The Installer must leave these instructions with the consumer who should retain for local inspector’s use and for future reference.
• Installation and service must be performed by a certied / licensed installer, service agency or gas supplier.
Your safety and the safety of others is very important. We have provided many important safety messages in this manual and on your
appliance. Always read and obey all safety messages.
IMPORTANT - PLEASE READ AND FOLLOW!
RATING PLATE - The location of
the rating plate is shown in Figure 1.
The information on the rating plate
denes the model, serial number,
gas type (natural or liquid propane),
operating pressures and burner BTU
ratings. Keep this information for
future reference. It is essential for
proper identication of the unit when
requesting additional information or
factory support.
Appliances must be connected
only to the type of gas identied
on the rating plate.
WARNING
!
3013256
MODEL: SERIAL NO.
AFCT-15 999999-CO9999
GAS TYPE: NA
TT
ANK ID#2
MAN. PRESS: IN. W.C.
4.0
INPUT-BTU/HOUR/BURNER CLEARANCES
NON-COMB. COMB.
30,000 BACK
SIDES
0”
0”
6”
6”
SUITABLE FOR INSTALLATION ON COMBUSTIBLE FLOORS
USING 6” ADJ. LEGS OR CASTERS.
INTENDED FOR OTHER THAN HOUSEHOLD USE.
ANSI Z83.11a/CSA 1.8a-2007 Food Service Equipment
RATING PLAT E
Figure 1
CLEARANCES - The appliance must be kept free and clear of all combustible materials.
This unit is designed and certied for the following installation only:
CLEARANCES
NON-COMBUSTIBLE COMBUSTIBLE
Sides 0" 6"
Rear 0" 6"
Floor 0" 6"
Installation on
non-combustible oor shall
be with factory supplied
legs or casters.
SHIPPING DAMAGE CLAIM PROCEDURE
The equipment is crafted and inspected carefully by skilled personnel before leaving the factory. The transportation company
assumes full responsibility for the safe delivery upon acceptance of the equipment.
If you receive a damaged product, immediately contact your delivery company, your dealer, your builder or installer. Do not
install or attempt to operate a damaged appliance.
1. Note any visible loss or damage on the freight bill or express delivery and have the note signed by the person making
the delivery.
2. File claim for damages immediately regardless of the extent of damages.
3. For damage noticed after unpacking (concealed loss or damage), notify the transportation company immediately and le
a “Concealed Damage” claim with them. This should be done within fteen (15) days from the date that delivery
is made to you. Retain the shipping container for inspection.
Rating Plate

INSTALLATION - GAS UTILITY CONNECTIONS-STANDARDS AND CODES
Qualied installation personnel, licensed and bonded, must be experienced in such work, familiar with all precautions required and
have complied with all requirements of state or local authorities having jurisdiction.
The ventilation of these fryers should be in accordance with local codes. In absence of local codes, refer to the national ventilation
code titled, Standard for the Installation of Equipment for the Removal of Smoke and Grease Laden Vapors from Commercial
Cooking Equipment, NFPA-96-Latest Edition.
The appliance is to be installed with a check valve in accordance with applicable federal, province and local codes.
Owner’s Manual Countertop Fryer
13592 Desmond St., Pacoima, CA 91331 818.897.0808 tel 888.753.9898 toll free www.americanrange.com
4
The installation instructions contained here are for the use of qualied
installation and service personnel only. Installation or service by other
than certied / licensed personnel will void the warranty and will result
in damage to the fryer and/or injury to the operator.
WARNING
!
The installation must conform with local codes, or in the absence of local codes, with the National Fuel Gas Code,
ANSI Z223.1NFPA54, or the Natural and Propane Gas Installation Code, CSA B149.1, as applicable, including:
1. The appliance and its individual shut-off valve must be disconnected from the gas supply piping
system during any pressure testing of that system at test pressure in excess of 1/2 PSI (3.5KPa).
2. The appliance must be isolated from the gas supply piping system by closing its individually manual shut-off valve during
any pressure testing of the gas supply piping system at test pressure equal to or less then 1/2 PSI (3.5KPa).
The gas supply line must be at least 3/4” ID (inside dimensions) size as the gas inlet of the appliance.
INSTRUCTIONS
The area around the appliance must be keep free and clear of combustibles such as solvents, cleaning liquid, broom, rags, etc.
All threaded joints of the appliance piping must be sealed with a compound that is resistant to the action of natural gas or liqueed
petroleum gases and the joint connection checked for gas leaks using a soapy water solution before lighting the pilots.
Proper clearances must be provided at the front of the appliance for servicing and proper operation.
For proper combustion and ventilation provisions shall be incorporated in the design of the kitchen, to ensure adequate supply of
fresh air and adequate clearance for air openings into the combustion chamber.
For proper operation of the appliance, do not obstruct the ow of combustion and ventilation air.
A manual gas shut-off valve shall be installed when the appliance is connected to the gas supply.
The rating plate is located inside of the left side panel.
The connecting wiring diagram is located on the lower inside of the left side panel.
INSTALLATION
When installing the pressure regulator - remember it can only handle 1/2 PSI. In
every LPG installation, you have high source pressures, ranging from 20 PSI to 100
PSI. If the high pressure gas line from the LPG tank is directly connected to the unit
without the proper step-down regulator, it will rupture the diaphragm in the valve,
rendering it useless.
WARNING
!
GENERAL EXPORT INSTALLATIONS - Installation must conform to Local and National Standards. Local installation codes
and/or requirements may vary. If you have any questions regarding the proper installation or operation of your American Range
Fryer, please contact your local distributor. If you do not have a local distributor, contact American Range Corporation at
1.888.753.9898 or visit us at www.americanrange.com

WARNING:
DO NOT CONNECT ANY
EXTERNAL ELECTRICAL
POWER TO THIS UNIT
THERMOPILE
COMBINATION
GAS VALVE
RED
BLACK
WHITE
RED
WHITE
COM
NC
NO
HI-LIMIT SWITCH
NO
C
THERMOSTAT
CAPILARY BULB
CAPILARY BULB
400
350
300
250
200
OFF
P
I
L
O
T
ON
OFF
WHITE
TP
TH TH
BLACK
WIRING DIAGRAM
Owner’s Manual Countertop Fryer
13592 Desmond St., Pacoima, CA 91331 818.897.0808 tel 888.753.9898 toll free www.americanrange.com
5

MODEL AND PARTS IDENTIFICATION
Owner’s Manual Countertop Fryer
13592 Desmond St., Pacoima, CA 91331 818.897.0808 tel 888.753.9898 toll free www.americanrange.com
6
COUNTERTOP FRYER
DESCRIPTION AFCT-15
Basket Hanger 1
Baskets 2
Rack/Screen 1
Burners 1
Drain Extension Pipe 1
Legs 4
Regis. Card 1
U&C Manual 1

CHECK ALL THAT APPLY
Appearance and Aesthetics
0Exterior
0Top section
0Oven interior
Installation
0Read User Manual
0Review Safety Instructions
0Proximity to cabinets
0Backguard in place
0Level
0Ventilation system
Ignition
0Top Burners
0Griddle
0Char Broiler
0Oven Burner
0Infrared Broiler
Controls
0Burner Knobs
0Thermostats
0Char Broiler
0Convection Oven Fan & Switch
0Oven Light Switch
Air/Gas Mixture
0Top Burners
0Griddle
0Char Broiler
0Oven Burner
0Infrared Broiler
Flame Adjustment
0Top Burners
0Griddle
0Char Broiler
0Oven Burner
0Infrared Broiler
Oven Door
0Alignment
0Door Seal
0Hinges
Valve Operation
0Top Burners
0Griddle
0Char Broiler
0Oven Burner
0Infrared Broiler
Customer Copy
Electrical Connection
0Correct voltage
0Grounded outlet
0Polarized outlet
0No GFCI
Gas Connection
0Verify fuel: 0Natural -or- 0LP
0Gas shut-off present and accessible
0Gas Supply line properly sized
0Gas Supply pressure checked
0Operating pressure checked
0All connections checked for leaks
INSTALLATION CHECKLIST
This checklist has been developed to assure proper installation of your oven.
To validate warranty, you must mail, e-mail or fax this form and a copy of your receipt to:
AMERICAN RANGE CUSTOMER SERVICE, 13592 DESMOND STREET, PACOIMA, CA 91331
818.897.8839 FAX
Street:___________________________________________
City, State, Zip Code:_______________________________
E-mail:__________________________________________
Telephone:______________________________________
Dealer:________________________________________
Purchase Date:___________________________________
Installation Date:__________________________________
Installer’s Name:__________________________________
Company:______________________________________
Telephone:______________________________________
Owner’s Manual Countertop Fryer
13592 Desmond St., Pacoima, CA 91331 818.897.0808 tel 888.753.9898 toll free www.americanrange.com
7

Owner’s Manual Countertop Fryer
13592 Desmond St., Pacoima, CA 91331 818.897.0808 tel 888.753.9898 toll free www.americanrange.com
8
BEFORE TURNING THE BURNER ON
1. Fill the vessel with a liquid oil up to the "Level" marking.
2. Do not operate fryer without oil in the vessel.
3. Do not overll the vessel.
LIGHTING
1. Before attempting to light this appliance, the door if so equipped, shall be open.
2. Turn the appliance manual gas shut-off valve to the OFF position.
3. Turn the combination gas control knob to the OFF position.
4. Turn the thermostat control to the OFF position.
5. Wait 5 minutes.
6. Turn the appliance manual gas shut-off valve to the ON position.
7. Turn the combination gas control knob to the PILOT position.
8. Light the pilot with a match while depressing and holding the combination gas control knob until the pilot remains
lit upon releasing the gas control knob.
9. Turn the combination gas control knob to the ON position.
10. Turn the thermostat control knob to the desired temperature to turn burners ON.
11. Ensure that the door is closed during operation.
12. For complete shutdown, repeat steps 2, 3, and 4.
LIGHTING INSTRUCTION is located on
the lower inside of the left side panel.
The installation instructions contained here are for the use of qualied
installation and service personnel only. Installation or service by other
than certied / licensed personnel will void the warranty and will result
in damage to the oven and/or injury to the operator.
WARNING
!
OPERATING INSTRUCTIONS
FRYING WITH SHORTENING
The type of fat that you use in frying inuences many qualities of the nished product such as avor, texture, shelf life and nutritional
attributes. How often you use the fryer – and the temperature that you cook at - will determine how long the fryer oil can be used
– most can last up to 100 hours.
Depending on the menu and local eating patterns, fryers will usually be operated at full capacity for a few hours a day, intermittently
for a few hours and be idle the reminder of the time. Operating a fryer on an intermittent basis is the primary reason that frying oil
must be discarded and replaced periodically. During the idle and low production periods, the oil is subjected to thermal and oxidative
stress more than it is during the active frying process. If fryers were operated without interruption and oil was ltered regularly, frying
oil would rarely need to be discarded.
Oil and shortening are two types of fat that are typically used in commercial deep fryers. Shortening comes in tubs or bricks
and quickly melts down to a liquid for frying purposes – however, it is not used as much now, because it is high in calories and fat.
Healthier fry oils like vegetable, canola, and the like are more commonly used in restaurants.
When deep fat frying, remember to never operate the fryer with the tank empty. The burners used in fryers are very powerful –
mainly to quickly heat the oil and to help recover heat during the cooking process. This power can damage a fryer tank, because the
metal of the tank – which is usually cooled by the oil – expands and this expansion could stress and fracture the welds.
So, the tank must be lled with water or cooking oil/shortening before lighting the burners. The bottom line is that failure to do so
will damage the tank and may even cause a re.
To deep fry with shortening, always start with an empty and/or cleaned-out tank and melt the shortening on the stove - carefully
pouring it into the tank. That way, you can be sure the shortening is in full contact with the fryer tank metal – eliminating the
potential of weld fracture from dry ring.

Owner’s Manual Countertop Fryer
13592 Desmond St., Pacoima, CA 91331 818.897.0808 tel 888.753.9898 toll free www.americanrange.com
9
1. Do not dry re the fryer; this will cause a leak. Dry ring is typically done after cleaning when the end user wants to dry
out the tank the "easy" way. It is a major cause of tank damage in the industry.
2. Do not drain the oil while it’s hot; wait until it cools before emptying. Rapid change in temperature causes stress
fractures and tears at the seams.
3. Do not use acidic cleaners; use only boil-out solution. Acid can cause erosion to metal and in due time can cause a leak
in tank.
4. Solid shortening must be liqueed before lling tank. The tank walls must have liquid against it in order to transfer heat
and avoid overheating and stressing the metal to the point of a tear.
5. Do not rinse off a hot tank with cold water. Always allow it to cool rst.
6. Do not use sharp tools to clean the fryer.
7. Keep your tank clean. Check for debris buildup at the bottom of the tank, and never allow too much build-up to occur.
WARNING
!
OPERATING INSTRUCTIONS
WEEKLY CLEANING
1. Shut down the fryer by turning the thermostat and pilot valve to the OFF position.
2. Disconnect the restraining device before moving the appliance for cleaning and servicing.
3. Drain the fryer into a ltered pan or steel container. Flush out sediment at the bottom of fryer with liquid oil.
4. Close the drain valve and ll the vessel with a mixture of boil-out solution and water.
5. Relight the pilot and turn on the burners.
6. When the solution starts to boil, turn off the thermostat and let the vessel
soak to soften deposits and/or carbon spots. Approximately one hour.
7. Drain off the solution, scrub the insides with brush and rinse thoroughly.
8. Repeat steps 4-7 if necessary.
9. Wipe dry with soft towels and rell with oil/shortening.
10. Re-connect the restraining device after returning the appliance to its originally installed position.
STAINLESS STEEL PARTS - Do not use steel wool, abrasive cloths, cleaners or powders to clean Stainless Steel surfaces. All
Stainless Steel parts should be wiped regularly with hot soapy water during the day and a Stainless Steel cleaner at end of the day.
To remove encrusted materials, soak in hot water to loosen the material - then use a wood or nylon scraper.
All water must be removed before adding oil or shortening. Not doing so can
result in splattering of hot oil causing severe burns and burn hazard.
WARNING
!
DO NOT DRY-FIRE; operating the unit without liquid is an extreme re hazard
and will cause irreparable damage such as gas leaks, scorched surfaces and burnt
components.
WARNING
!

Owner’s Manual Countertop Fryer
13592 Desmond St., Pacoima, CA 91331 818.897.0808 tel 888.753.9898 toll free www.americanrange.com
10
27
26
25
7
21
8
910
11
12
13
19 18
17
22
24
23
28
20
16 15
14
5
2
4
3
1
6
AFCT - 15

Owner’s Manual Countertop Fryer
13592 Desmond St., Pacoima, CA 91331 818.897.0808 tel 888.753.9898 toll free www.americanrange.com
11
ITEM NO. PART NO. DESCRIPTION
1A33004 Basket, AFCT Countertop Fryer Chrome Plated
2A31087 Rack, AFCT-15 Mesh Screen Chrome Plated
5A99360 Tank, AFCT-15 Fryer 16GA 304SS
671673 Hanger, Basket AFCT 18GA Stainless
10 71625 Panel, Side Rt AFCT 18GA Stainless
12 A50400 Thermostat, RX Millivolt AF
13 A10007 Switch, Hi-Limit Millivolt AF
16 71658 Bracket, Thermostat AFCT 16GA Aluminized
17 71661 Top Hinge Assembly
18 A32013 KNOB, RX Thermostat AF-Series
19 A24000 Elbow, Orice Mixr 3/8C-3/8-27
20 A11114 Pilot, 3CH-6.016 Nat Gas
21 71659 Bottom Hinge Assembly
22 TBD Valve, Combination Safety Regulator Nat
TBD Valve, Combination Safety Regulator LPG
24 TBD Tubing
25 Leg
26 A29000 Orice, Hood, #39 1/2" Brass
27 A14052 Burner, AFCT-15 Infrared Inconel®
28 71645 Drain Tube Extension
29 A43104 Magnet, Door AF Series
30 71677 Handle, Door AFCT-15
31 Logo, American Range Emblem
32 Speed Nut
33 71671 Landing Edge, AFCT 18GA Stainless
34 71624 Panel, Side LT AFCT 18GA Stainless
AFCT - 15

TROUBLESHOOTING GUIDE
POSSIBLE CAUSE SUGGESTED ACTION
SYMPTOM: Burners do not come on.
Unit is not connected to gas service Visually check unit is plumbed to gas
Pilot is not burning Light pilot
Thermostat is set to very low temperature Set temperature to desired value
SYMPTOM: Fryer does not reach selected temperature.
Unit may not have been operating long enough Unit preheats to 350ºF in about ten minutes
Thermostat may be defective Unit will require service
Too little gas pressure, dirty gas line Call for authorized service
SYMPTOM: General frying problems.
Temperature too low or too high Set unit to recommended temperature for foods being fried.
Thermostat out of calibration Unit will require service
Always disconnect the gas service before cleaning or
servicing the fryer.
WARNING
!
Owner’s Manual Countertop Fryer
13592 Desmond St., Pacoima, CA 91331 818.897.0808 tel 888.753.9898 toll free www.americanrange.com
12

Notes
13592 Desmond St., Pacoima, CA 91331 818.897.0808 tel 888.753.9898 toll free www.americanrange.com

Notes
13592 Desmond St., Pacoima, CA 91331 818.897.0808 tel 888.753.9898 toll free www.americanrange.com

Notes
13592 Desmond St., Pacoima, CA 91331 818.897.0808 tel 888.753.9898 toll free www.americanrange.com

13592 Desmond Street, Pacoima, CA 91331
818.897.0808 tel 888.753.9898 toll free
818.897.1670 fax
www.americanrange.com
WARRANTY REQUIREMENT
For reliable operation and for your own safety, this professional cooking equipment must
be installed by a certied/licensed contractor.
Failure to comply will void any written or implied warranty.
Should the equipment require service during the standard warranty period, the receipt
proving certied installation must be made available to American Range for verication.
If installation was not performed by a certied/licensed contractor be prepared to submit
a major credit card for payment for proper installation prior to service.
A70695 060612
Table of contents
Other American Range Fryer manuals
Popular Fryer manuals by other brands

Frymaster
Frymaster FootPrint PRO OCF30 Series Service & parts manual

Ninja
Ninja Foodi MAX AF400UK user manual

Frymaster
Frymaster H14 Series Installating and operation manual

Brentwood Select
Brentwood Select AF-200BL Operating and safety instructions

Oster
Oster CKSTHF-049 instruction manual

PIMAK
PIMAK FR70SD-M073 user guide