OPERATION:The remote programmer has 4 keys:
“Enter” or validate
“Cancel”
“Scroll UP”
“Scroll Down”
The ‘Down’ Key is also used to turn “ON” the remote programmer. After
not being used for 2 minutes, the programmer automatically turns itself off.
DISPLAY
Mini-USB Port
Transmission Area

3
When using the programmer, the sensor will begin blinking for approximately 5
seconds after the “enter” key is pressed and the display shows “TRANSMISSION
OK”. While it is blinking move your finger to within 1 inch of the sensor (nearly
covering it). When the light stops blinking and stays on steady, remove your finger
and, with the palm of your hand facing the sensor, move your hand to the distance
to be set. When the sensor starts to blink again, move you hand away from the
detection area. The flashing will stop and the sensor will now be programmed with
the new setting. The Programmer will now display BACKUP FUNCTION. You can
program the next sensor(s) by pointing the programmer at the sensor and
pressing the “enter” key. The programmer will remember the programmed settings
for approximately 3.5 minutes before turning off.
NOTE: See “Product Settings & Specifications Chart”
Setting The Detection Distance
*** ONLY DONE AFTER SELECTING ALL THE MODE SETTINGS ***

4
ON
MENU 1
CLEANING
MENU 2
DISINFECTION
Press to activate the menus
Press to turn on the programmer
DISINFECTION
DURATION :114min
Press up or down to adjust time
Align the programmer with the sensor and press to
transmit the signal to sensor to activate the
DISINFECTION cycle for the selected period of time
MENU 3
DIAGNOSTIC Align the programmer with the sensor and press to
transmit the signal to sensor to activate the
DIAGNOSTIC feature. NOTE: Use the up and down
arrow keys to scroll through the current settings
Press to go to MENU 2
Press to go to MENU 3
Press to go to MENU 4
To MENU 4
¾Start
¾Cleaning
¾Disinfection
¾Diagnostics
TIP: Cleaning – Use this mode to disable the
sensor for 1 minute. This is sometimes used by
the cleaning crew to keep the faucet “off” while
cleaning the fitting and or fixture.
TIP: Disinfection – This is typically used in
healthcare facilities that conduct periodic high
temperature or high anti-bacterial chemical
purging of the water lines. The maintenance
person should activate this mode and stay
present to avoid any users from exposure to
the purged water. This ‘mode’ can be activated
while in any function (hand-wash faucet, urinal
flush valve, etc.). The duration (run time) can be
programmed from 1 minute to 120 minutes in 1
minute intervals.
TIP: Diagnostics – Use this mode to determine
the settings of the faucet or flush valve. NOTE:
this feature will only work with products made
2008 or newer.

5
MENU 4
PARAMETER
SENSOR
2008 VERSION
SENSOR
2003 VERSION
From MENU 3
MENU 5
LANGUAGE
MENU 5.1
Francais
Press up or down to select
language – French, English,
Spanish, Italian, or German
MENU 6
BACKLIGHT
BACKLIGHT
Press up or down to select
display backlight intensity
Press to set selected
language
Press to set selected display
intensity for easy reading in
different lighting conditions.
NOTE: Not all features
available with this version
From this menu,
scroll down to the
specific mode you
want to program:
¾Parameter
¾Language
¾Backlight
• Hand-Wash
• Metering
•On/OFF
•Urinal
•LFUrinal+PF**(NOT USED)**
• Flushometer
• Kitchen **(NOT USED)**
• DB Toilet
TIP: Sensor Version – Select 2008 for all
Selectronic products manufactured from 2008
to present day. Select 2003 for products
manufactured from 2003 through 2007. **If
unsure, use the 2008 setting. If repeated
transmission errors occur, then try the 2003
setting.

6
MENU 4.1
HAND-WASHER
COMF. TIMEOUT
= 1 Sec
Press up or down to adjust time
SAFETY Timeout
= 55 s
Press up or down to adjust time
Auto. RINSE
= OFF
To MENU 4.2
Press to set
¾Hand-Wash -- Faucet
From MENU 4
NOTE: This is the standard ‘instant on /
instant off’ faucet mode.
TIP: The “COMF. TIMEOUT” (Comfort Timeout)
determines how long the water will run after the users'
hands are removed from the detection zone. This
prevents the water from quickly turning On & Off as
the user’s hands move in & out of the detection zone.
Recommended setting: 1.5 sec
•Adjustable from 0 to 10 sec in 0.5 sec increments
TIP: The “Auto. RINSE” (Auto Purge) allows the
faucet to automatically turn ON after a set time period
of non use, maintaining the trap seal & preventing the
water from becoming stagnant
Default Setting: ‘OFF’
•This time period can be set to activate from 1 to 72
hrs (of non-use) in 1 hr increments.
•The duration of run time can be set from 1 sec. to
240 sec.
Auto. RINSE
= 55 s
Press up or down to adjust time
Align the programmer with the sensor
and press to transmit the program, with
the Auto Rinse ON, to the sensor
Press up or down to turn ON
the Auto Rise feature and
adjust frequency
TIP: The “SAFETY Timeout” is sometimes referred to
as the ‘Vandal Timer’. This should be set ON to
prevent someone from intentionally blocking the eye
(chewing gum, tape, etc) to keep the faucet running
and have the sink overflow.
Default Setting: 55 sec
•Adjustable from 5 to 120 sec in 5 sec increments
Setting the sensor to the Hand-Wash faucet mode:
- Set the "Comfort Timeout"
- Set the "Safety Timeout"
-Set"Auto-Rinse" frequency (if the frequency is set to 0,
‘auto-rinsing” (auto-purging) is Off)
- Set the "Duration" (run time) of the auto-rinsing process.

7
MENU 4.2
METERING
From MENU 4.1
COMF. TIMEOUT
= 15 Sec
Press up or down to adjust
metering run time
Auto. RINSE
= OFF
Auto. RINSE
= 15 s
Press up or down to turn ON
the Auto Rise feature and
adjust frequency
Align the programmer with the sensor
and press to transmit the program, with
the Auto Rinse OFF, to the sensor
Press up or down to adjust time
Align the programmer with the sensor
and press to transmit the program, with
the Auto Rinse ON, to the sensor
To MENU 4.3
¾Metering -- Faucet
TIP: In this Metering Mode, the “COMF. TIMEOUT”
(Comfort Timeout) is the RUN TIME - how long the water
will run once activated by the user.
•Run Times: 1, 2, 3.25, 7.5, 10, 15, 30, 60, or 120
seconds
(RUN TIME)
Setting the sensor to the Metering faucet mode:
- Set the "Comfort Timeout" (run time)
-Set"Auto-Rinse" frequency (if the frequency is set to 0,
‘auto-rinsing” (auto-purging) is Off)
- Set the "Duration" (run time) of the auto-rinsing process.
TIP: The “Auto. RINSE” (Auto Purge) allows the faucet
to automatically turn ON after a set time period of non
use, maintaining the trap seal & preventing the water
from becoming stagnant
Default Setting: ‘OFF’
•This time period can be set to activate from 1 to 72
hrs (of non-use) in 1 hr increments.
•The duration of run time can be set from 1 sec. to 240
sec.

8
MENU 4.3
ON/OFF
From MENU 4.2
COMF. TIMEOUT
= 15 Sec
Press up or down to adjust
metering run time
Auto. RINSE
= OFF
Auto. RINSE
= 15 s
Press up or down to turn ON
the Auto Rise feature and
adjust frequency
Align the programmer with the sensor
and press to transmit the program, with
the Auto Rinse OFF, to the sensor
Press up or down to adjust time
Align the programmer with the sensor
and press to transmit the program, with
the Auto Rinse ON, to the sensor
To MENU 4.4
¾Metering with On/Off -- Faucet
NOTE: This is actually uses the ‘Metering’ mode, but
with the added feature of being able to start and stop
the water flow before the metering time runs out.
TIP: In this "Metering with On/Off’ Mode, the “COMF.
TIMEOUT”istheRUN TIME - how long the water will run
once activated by the user. The detection distance is set
very short, so the user must start & stop the water by
moving hands close to the sensor. - This is suited for
gooseneck type fittings where the movement of the user
may be outside the normal detection zone.
•Run Times : 1, 2, 3.25, 7.5, 10, 15, 30, 60, or 120
seconds
Setting the sensor to the Metering faucet mode:
- Set the "Comfort Timeout" (run time)
-Set"Auto-Rinse" frequency (if the frequency is set to 0,
‘auto-rinsing” (auto-purging) is Off)
- Set the "Duration" (run time) of the auto-rinsing process.
TIP: The “Auto. RINSE” (Auto Purge) allows the faucet
to automatically turn ON after a set time period of non
use, maintaining the trap seal & preventing the water
from becoming stagnant
Default Setting: ‘OFF’
•This time period can be set to activate from 1 to 72
hrs (of non-use) in 1 hr increments.
•The duration of run time can be set from 1 sec. to 240
sec.

9
MENU 4.4
URINAL
From MENU 4.3
DETEC. INTERVAL
= 3 Sec
Press up or down to adjust
the required user detection
activation time
RINSE START INT
= 5
Auto. RINSE
= 55 s
Press up or down to adjust
how long to wait after the
user leaves to begin the flush
Press up or down to
adjust the frequency
Align the programmer with the sensor
and press to transmit the program, with
the Auto Rinse ON, to the sensor
To MENU 4.5
Auto. RINSE
= 24 h
Scroll down to turn
the Auto Rinse
feature OFF
Auto. RINSE
= 72 h
Auto. RINSE
= OFF
Press up or down to adjust
the Auto Rinse run time
Align the programmer with the
sensor and press to transmit
the program, with the Auto
Rinse OFF, to the sensor
RINSE
= 5 s
Press up or down to
adjust Flush Time
¾Urinal -- Urinal Flush Valve
TIP: The "DETEC. INTERVAL" (Detection Interval) is how
long a user must be in the detection zone to arm the flush
valve. This eliminates false flushing due to people walking
past the urinals. Recommended setting is 5 sec.
TIP: The "RINSE START INT." (Rinse Start Interval) is
how long after the user leaves the detection zone before
the valve will flush. Recommended setting is 3 sec.
TIP: The "Rinse'" is the Flush Time (Flush Duration).
See Flush Valve Settings Chart
TIP: The "Auto. RINSE'" (Sanitary Flush) allows the
flush valve to automatically flush, after a set time period
of non-use, to maintain the trap seal . This time period
can be set to activate from OFF to 72 hrs (of non-use) in
1 hr increments. You can set the duration of flush time
from 1 sec. to 240 sec. –never more than the fixture
can drain before overflowing! (Recommended
setting is OFF unless prolonged non-use is
expected – then 2 s should maintain the trap seal).
Default Setting: ‘Off’

10
MENU 4.6
FLUSHOMETER
From MENU 4.4
To MENU 4.7
MENU 4.5
LF URINAL + PF
DETEC. INTERVAL
= 3 Sec
Press up or down to adjust the
user detection activation time
RINSE START INT
= 7
Auto. RINSE
= 55 s
Align the programmer with the sensor
and press to transmit the program, with
the Auto Rinse ON, to the sensor
Auto. RINSE
= OFF
Auto. RINSE
= 72 h
Press up or down to adjust
the Auto Rinse run time
RINSE
= 7 s
Press up or down to
adjust Flush Time
Press up or down to turn
ON the Auto Rise feature
and adjust frequency
Align the programmer with the sensor
and press to transmit the program, with
the Auto Rinse OFF, to the sensor
NOT USED
¾Flushometer – Toilet Flush Valve
MENU 4.7
KITCHEN NOT USED
Press up or down to adjust
how long to wait after the
user leaves to begin the flush
TIP: The "Auto. RINSE'" (Sanitary Flush) allows the
flush valve to automatically flush, after a set time period
of non-use, to maintain the trap seal . This time period
can be set to activate from OFF to 72 hrs (of non-use) in
1 hr increments. You can set the duration of flush time
from 1 sec. to 240 sec. –never more than the fixture
can drain before overflowing! (Recommended
setting is OFF unless prolonged non-use is
expected – then 2 s should maintain the trap seal).
Default Setting: ‘Off’
TIP: The "DETEC. INTERVAL" (Detection Interval) is how
long a user must be in the detection zone to arm the flush
valve. This eliminates false flushing due to people walking
past the urinals. Recommended setting is 5 sec.
TIP: The "RINSE START INT." (Rinse Start Interval) is
how long after the user leaves the detection zone before
the valve will flush. Recommended setting is 3 sec.
TIP: The "Rinse" is the Flush Time (Flush Duration).
See Flush Valve Settings Chart

11
MENU 4.8
DB Toilet
From MENU 4.4
DETEC. INTERVAL
= 3 Sec
Press up or down to adjust the
user detection activation time
RINSE START INT
= 7
Auto. RINSE
= 55 s
Align the programmer with the sensor
and press to transmit the program, with
the Auto Rinse ON, to the sensor
Auto. RINSE
= OFF
Auto. RINSE
= 72 h
Press up or down to adjust
the Auto Rinse run time
RINSE
= 7 s
Press up or down to
adjust Flush Time
Press up or down to turn
ON the Auto Rise feature
and adjust frequency
Align the programmer with the sensor
and press to transmit the program, with
the Auto Rinse OFF, to the sensor
¾Dual Flush – Toilet Flush Valve
SHORT RINSING
= 1.5 Sec
Press up or down to adjust
how long to wait after the
user leaves to begin the flush
TIP: The "Short Rinsing" is the is the flush time used
when the user stays in the detection zone for less than 1
minute. – This should be the setting for the lowest of the 2
flush volumes listed for this model flush valve. – See Flush
Valve Settings Chart
TIP: The "Rinse" is the Long Flush Time (Flush Duration) if
the user stays in the detection zone for longer than 1 minute.
See the Flush Valve Settings Chart
TIP: The "DETEC. INTERVAL" (Detection Interval) is how
long a user must be in the detection zone to arm the flush
valve. This eliminates false flushing due to people walking
past the urinals. Recommended setting is 5 sec.
TIP: The "RINSE START INT." (Rinse Start Interval) is
how long after the user leaves the detection zone before
the valve will flush. Recommended setting is 3 sec.
TIP: The "Auto. RINSE" (Sanitary Flush) allows the
flush valve to automatically flush, after a set time period
of non-use, to maintain the trap seal . This time period
can be set to activate from OFF to 72 hrs (of non-use) in
1 hr increments. You can set the duration of flush time
from 1 sec. to 240 sec. –never more than the fixture
can drain before overflowing! (Recommended
setting is OFF unless prolonged non-use is
expected – then 2 s should maintain the trap seal).
Default Setting: ‘Off’

Table of contents