manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. AMES
  6. •
  7. Control Unit
  8. •
  9. AMES 400 Series User manual

AMES 400 Series User manual

This manual suits for next models

5

Other AMES Control Unit manuals

AMES SILVER BULLET 2000SS Series User manual

AMES

AMES SILVER BULLET 2000SS Series User manual

AMES 1000SS Series User manual

AMES

AMES 1000SS Series User manual

AMES Maxim M300 Series Setup guide

AMES

AMES Maxim M300 Series Setup guide

AMES 910GD-01 Installation and operating instructions

AMES

AMES 910GD-01 Installation and operating instructions

AMES A200 User manual

AMES

AMES A200 User manual

AMES 2000B Series User manual

AMES

AMES 2000B Series User manual

AMES Colt Series Instruction Manual

AMES

AMES Colt Series Instruction Manual

AMES Colt Series Use and care manual

AMES

AMES Colt Series Use and care manual

AMES 2000 CIV Series Setup guide

AMES

AMES 2000 CIV Series Setup guide

AMES 972GD-19 Installation and operating instructions

AMES

AMES 972GD-19 Installation and operating instructions

AMES SILVER BULLET 2000SS Series User manual

AMES

AMES SILVER BULLET 2000SS Series User manual

AMES 2000SS Series Instruction Manual

AMES

AMES 2000SS Series Instruction Manual

Popular Control Unit manuals by other brands

Seitz 14A80 user manual

Seitz

Seitz 14A80 user manual

Wilo RS485 Installation and operating instructions

Wilo

Wilo RS485 Installation and operating instructions

Becker CentralControl CC41 Commissioning Instruction

Becker

Becker CentralControl CC41 Commissioning Instruction

SICK CDB650 operating instructions

SICK

SICK CDB650 operating instructions

Panduit NetKey NKP5E88M Series installation instructions

Panduit

Panduit NetKey NKP5E88M Series installation instructions

MX Options Concentric Petite Fitting instructions

MX

MX Options Concentric Petite Fitting instructions

Clean Water Systems Fleck 2510 Installation & start?up guide

Clean Water Systems

Clean Water Systems Fleck 2510 Installation & start?up guide

Fairchild FSB44104A user guide

Fairchild

Fairchild FSB44104A user guide

LEGRAND Wattstopper LMIN-104 installation instructions

LEGRAND

LEGRAND Wattstopper LMIN-104 installation instructions

PMK ATT10BNCS instruction manual

PMK

PMK ATT10BNCS instruction manual

Tektronix TDS3FFT user manual

Tektronix

Tektronix TDS3FFT user manual

Woodward easYgen Technical manual

Woodward

Woodward easYgen Technical manual

Balluff BNI EIP-502-105-R015 user guide

Balluff

Balluff BNI EIP-502-105-R015 user guide

NXP Semiconductors TWR-LS1021A Getting started

NXP Semiconductors

NXP Semiconductors TWR-LS1021A Getting started

Advantech PCM-3117 Startup manual

Advantech

Advantech PCM-3117 Startup manual

Danfoss MCO 101 manual

Danfoss

Danfoss MCO 101 manual

Moons' Lin Engineering R701P user manual

Moons'

Moons' Lin Engineering R701P user manual

Aventics RV1 operating instructions

Aventics

Aventics RV1 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

IS-A-AirGaps
Air Gap Installation Instructions
Limited Warranty: Ames Company warrants each product to be free from defects in
material and workmanship under normal usage for a period of one year from the date of
original shipment. In the event of such defects within the warranty period, the Company
will, at its option, replace or recondition the product without charge. This shall constitute
the sole and exclusive remedy for breach of warranty, and the Company shall not be
responsible for any incidental, special or consequential damages, including without
limitation, lost profits or the cost of repairing or replacing other property which is
damaged if this product does not work properly, other costs resulting from labor charges,
delays, vandalism, negligence, fouling caused by foreign material, damage from adverse
water conditions, chemical, or any other circumstances over which the Company has no
control. This warranty shall be invalidated by any abuse, misuse, misapplication or
improper installation of the product. THIS WARRANTY IS IN LIEU OF ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY IMPLIED WARRANTIES OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Any implied warranties
that are imposed by law are limited in duration to one year.
Some States do not allow limitations on how long an implied warranty lasts, and some
States do not allow the exclusion or limitation of incidental or consequential damages.
Therefore the above limitations may not apply to you. This Limited Warranty gives you
specific legal rights, and you may have other rights that vary from State to State. You
should consult applicable state laws to determine your rights.
Series 4000SS and 5000SS Air Gaps
Sizes: 21⁄2" - 10" (65 – 250mm)
1. Remove L shape bracket from one side of air gap drain.
2. Remove screw from one side of the splash guard.
3. Slide one half of the splash guard into the groove on the relief
valve body.
4. Slide the other half of the splash guard into the groove on the
relief valve body and reassemble the two parts together.
5. Reattach the L shape brackets long side up into slots in the
splash guard with screws.
6. Push as much of the sensing hose as possible into the air
gap drain funnel to prevent over spray.
Series 400 and 500 Air Gaps
Sizes: 21⁄2" - 10" (65 – 250mm)
Ames Air Gap Drains are designed to collect water that is being discharged by the relief valve, due to
minor check valve fouling and/or line pressure fluctuations.
Note: Air Gap Drains are not designed to collect the full discharge capacity of the relief valve.
Horizontal
1. Remove two of the relief valve capscrews 180° apart.
2. Remove the relief valve hose from fitting below inlet ball valve.
3. From the top of the air gap, thread the relief valve hose down
and out the slot.
4. Use 1⁄4: - 20 UNC x 1" long stainless steel screws.
5. Reconnect relief valve hose to the fitting below the inlet ball
valve (Fig. 1).
Vertical
1. Detach the sensing line from the inlet ball valve and the elbow
on the relief valve.
2. Remove the elbows from the relief valve base.
3. Hang the Air Gap Drain on the body of the relief valve (Fig. 2).
4. Reinstall the elbow into the base of the relief valve to hold the
Air Gap Drain in place.
5. Install the rigid fitting end of the sensing line to the elbow on
the base of the relief valve and the swivel end to the fitting on
the ball valve.
Fig. 1
Splash
Guard
Fig. 2
www.amesfirewater.com
IS-A-AirGaps 0317 ©Ames Co. 2003 Printed in U.S.A.
EDP# 1915367
A Division of Watts Industries www.amesfirewater.com
875 National Drive • Suite #107 • Sacramento, CA 95834 • Phone: 916-928-0123 • Fax: 916-928-9333
Series 4000B and 5000CIV Air Gaps
Sizes: 1⁄4" - 10" (8-250mm)
1. Air Gap installs easily to the bottom of the 4000B or 5000CIV
backflow assembly relief valve.
2. Attach to the outlet of the relief valve using screws.
3. For vertical installations use optional elbows as shown in Fig. 4
Air Gap
4000B
Ames 4000B
1⁄2"- 2"
(15-50mm)
Elbow
Air Gap
Figure 4
Figure 3
Ames 5000CIV
Size: 21/2" – 10"
(65-250mm)
Air Gap