10
SPECIFICATIONS
Measuring Ranges: 300A/3000A
Output Sensitivity: 1mV/0.1mV/A (AC coupled)
Accuracy: (at 25°C) ±1% of range
Frequency Range: 10Hz to 5kHz
Phase Error: ±1º (45 to 65 Hz), ±10º (at 5 kHz)
Linearity: ±0.2% of reading from 10% to 100% of range
Position Sensitivity: ±2% of range, cable >25mm (1”) from coupling
External Field: ±1% with cable >200mm (8”) from head
Minimum Load: 100kW for specified accuracy
Noise Level: 1.0mV rms (0.3% of range)
Operating Temperature: -20°C to 85°C (-4°F to 185°F) Electronics
Storage Temperature: -20°C to 85°C (-4°F to 185°F) Electronics
Gain Variation: ±0.08%/°C
Common Mode Voltage: Voltage between the Output the Earth must not
exceed 30V
Power Supply: 2 x AA/MN1500 LR6 (1.5V) batteries
Battery Life: 4000 hours, 3000 hours typical (4 months cont.)
Low Battery Indication: Red LED flashing
External Power: Battery eliminator, via 2.1mm connector, 3V DC
Socket type A16M500
Safety: BS EN61010-1: 1993, 600V CATIII Pol. Deg 2
EMC: EN61326: 1998
Enclosure: IP5X, Flame retardant UL94-VO rated
Material: Valox 357 X
Output Connections: Hypotronics connector type DO1EEB306FST
Weight: 0.19 kg (0.4 lb)
Measuring Head
Cable length: 610mm (24 inches), double insulated
Cable Diameter: 14.3mm (0.562 inches)
Bend Radius: 38.1mm (1.5 inches) minimum
Connecting Cable: 2m (78.7 inches) long, double insulated
Material: TPE rubber, Polypropylene, UL94-VO rated
Operating Temperature: -20°C to +90°C (-4°F to 194°F) Head
Storage Temperature: -40°C to +105°C (-40°F to 221°F) Head
Safety: BS EN 61010-1: 1993, 600V CAT III Pol. Deg 2
Weight: 0.18kg (0.4 lb)