MCU SERIAL IR OUTPUT CONTACT
RELAY IR INPUT AX LINK DTMF
10baseT
OUT 2 OUT 1
PORT 2 PORT 1
OUT 3
OUT 4
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
+12
+5
C1
GND
C2
GND
C3
GND
C4
GND
C5
GND
C6
GND
C7
GND
GND AXM AXP +12V
PROGRAM
INPUT 1
INPUT 3 INPUT 2
PHAST HUB
DATA POWERPORT 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
PHAST
HUB
OUT
PHAST
HUB
IN
PLB-CF10 CardFrame Control Cards
cf10 cardframe
ARGENTINA • AUSTRALIA • BELGIUM • BRAZIL • CANADA • CHINA • ENGLAND • FRANCE • GERMANY • GREECE • HONG KONG • INDIA • INDONESIA • ITALY • JAPAN
LEBANON • MALAYSIA • MEXICO • NETHERLANDS • NEW ZEALAND • PHILIPPINES • PORTUGAL • RUSSIA • SINGAPORE • SPAIN • SWITZERLAND • THAILAND • TURKEY • USA
ATLANTA • BOSTON • CHICAGO • CLEVELAND • DALLAS • DENVER • INDIANAPOLIS • LOS ANGELES • MINNEAPOLIS • PHILADELPHIA • PHOENIX • PORTLAND • SPOKANE • TAMPA
3000 RESEARCH DRIVE, RICHARDSON, TX 75082 • 800.222.0193 • 469.624.8000 • +1.469.624.7400 • 469.624.7153 fax • www.amx.com
©2006 AMX. All rights reserved. AMX and the AMX logo are all trademarks of AMX. AMX reserves the right to alter specifications without notice at any time.
PLB-CF10 CARDFRAME
•Holds up to 10 control cards
•Acts as system master with Master
Control Card
•Operates interactively over high-speed
Ethernet connection to system PC with
AMX software and PLC-MCU Card
•Distributes PhastLink from 15-port
PhastLink data hub
CARD SLOTS
•10 rear-access slots
HUB LINK
• 2 RJ-45 ports to hubs and Cardframes
PHASTLINK
•15 RJ-45 PhastLink ports
DIP SWITCH
•Sets Cardframe device number
DIMENSIONS (HWD)
•5.56" x 17.13" x 15.25"
(141.2 mm x 435.1 mm x 387.4 mm)
WEIGHT
•19.8 lbs (9.0 kg) (w/o cards)
POWER
•110/220 VAC, 50/60 Hz, 100 mA (w/o
cards)
ACCESSORIES
•PM-RAC Rack-Mount Kit,
requires 3 rack spaces (5.25")
CONTROL CARDS:
PLC-MCU4
MASTER CONTROL CARD, 4 MEG
Application: Master system processing and
memory one required per
system
PanjaLan: RJ-45 Ethernet 10baseT port
to system PC
Memory: 4 MB flash, 4 MB SRAM
Power: 480 mA
PLC-AMX AMX EMULATION CARD
Application: Link up to 255 AMX devices
AXLink: 4-pin AMX AXlink data/power
bus
Program: 9-pin male D-Sub programming
connector
Power: 130 mA*
PLC-DTMF
TELEPHONE INTERFACE CARD
Application: Caller ID, additional applications
with future software releases,
limit one per system
Line In: RJ-11 jack
Phone: RJ-11 jack
Audio: RCA line-level audio in and out
Power: 35 mA
PLC-IN7 CONTACT INPUT CARD
Application: Sense closures or voltage
changes
Inputs 1-7: 7 inputs, closure or 1.6-30
VAC/DC voltage change
auto-reset fuse protected
Power: +12 and +5 VDC power for
accessories, 1 A max
Wiring: Removable 16-pin screw terminal
Power: 25 mA*
PLC-IRIN IR INPUT CARD
Application: Accepts AMX IR commands
from up to 3 sensors
IR In 1–3: 3 inputs for industry-standard
IR sensors
Wiring: 3 3-pin screw terminals for
sensor data and power
Power: 45 mA
PLC-IROUT IR OUTPUT CARD
Application: Control of IR-format sources
Ports 1-4: 4 outputs, IR or wired IR up 10
MHz
Wiring: 4 mini-phono jacks for emitter
or wired IR cable
Power: 75 mA
PLC-RL8 RELAY CARD
Application: Control closure-activated
sources
Relays 1-8: 8 dry-contact relays,
1A@30 VDC
Jumpers: Set relays to NC/NO operation
Wiring: 16-pin screw terminal
Power: 360 mA
PLC-SER DUAL SERIAL CARD
(RS-232, RS-422/485)
Application: Bi-directional serial control
Port 1: RS-232/422/485, 300-56,000
baud, CTS/RTS
Port 2: RS-232, 300-56,000 baud,
CTS/RTS
Wiring: 2 9-pin male D-Sub connectors
Power: 80 mA
*May need additional power to operate
connected devices