Installation Guide
AXR-RF RF Receiver
Overview
The AXR-RF Radio Receiver provides wireless reception of AMX radio
frequency (RF) transmitters. The AXR-RF connects to an Axcess Central
Controller with an AXlink, 4-pin captive-wire connector. When required for
large areas, or multiple-room coverage, multiple receivers can be
connected in parallel on the AXlink bus.
Installation
Configuring the AXR-RF
Use the eight-position DIP switch on, the rear of the AXR-RF, to set the
device number. A device number is assigned to devices connected to the
AXlink bus. Every device on the bus must have a unique device code. The
device number must match the device assignment in the Axcess program.
AMX assigns device numbers in three groups:
• Axcess Control Cards: 1 - 95
• Axcess Bus Boxes: 96 - 127
• Axcess Panels/Receivers: 128 - 255
Setting the DIP Switch
Locate the device DIP switch on the rear panel of the AXR-RF and set it to
the desired binary device number. The device number is set by the total
value of DIP switch positions that are ON (down).
NOTE: If you change the device number, remove and reconnect the AXlink
connector. This enters the new device number into memory.
Although the AXR-RF is a bus device, it should be numbered in the 128-255
range, because it is a receiver.
Setting the RF Validation Level
An RF transmitter must send repetitions of data for the receiver to accept it
as valid data. In some installations, interference and physical structures
may interfere with the receiver's ability to detect the transmitted signal. The
signal may become distorted. The receiver can be set to use either two or
three repetitions of sequential signals to validate and accept the signal
data. To set the receiver's RF level.
1. Locate jumper pins labeled P3 on the circuit board.
2. Position the P3 RF validation jumper to select the number of valid RF
data repetitions to be accepted, as shown in FIG. 2:
Wiring Guidelines
The AXR-RF requires regulated ±12 VDC power to operate properly. The
Central Controller supplies power via the AXlink cable. The maximum
wiring distance between the Central Controller and AXR-RF is determined
by power consumption, supplied voltage, and the wire gauge used for the
cable. The table below lists wire sizes and maximum lengths allowable
between the AXR-RF and Central Controller. The maximum wiring lengths
for using AXlink power are based on a minimum of ±13.5 VDC (no load
voltage), available at the Central Controller's power supply.
FIG. 1 AXR-RF RF Receiver
Specifications
Power Consumption 780 mW; ±12 VDC, 65 mA (max.)
Dimensions (HWD) 1.5" x 5.09" x 5.27" (3.81 cm x 12.93 cm x 13.39 cm)
Weight 10.56 oz. (299.37 g)
Front Panel Components:
Radio data LED Red LED lights to indicate the AXR-RF has received an RF signal
from an AMX transmitter.
AXlink LED Green LED that lights to indicate AXlink power/data status as fol-
lows:
• One blink/second indicates power is active and AXlink
communication is working.
• Two blinks/second indicates the devices specified in the main
program do not match the devices found.
• Three blinks/second indicates there is an AXlink communication
error
• Full on indicates there is either no AXlink control/activity (but the
power is On) or the Axcess program is not loaded.
Rear Panel Components:
AXlink connector 4-wire captive-wire AXlink connector for the Central Controller pro-
vides data and nominal ±12 VDC power.
Device number DIP Switch 8-position DIP switch sets the device number for the AXR-RF.
RF antenna Receiving antenna screws into the TXC antenna connector. If it is
necessary to place the antenna in a remote position, use up to 6 ft.
(2 m.) of RG-174 coax cable as an extension. Extend the antenna
vertically during use.
TXC antenna connector Antenna coaxial connector
Receive Frequency 418 MHz standard (other frequencies are available)
Maximum Range 300 feet (91.44 m)
Enclosure Molded black matte plastic
Options • Alternate frequencies available
• PS2.8 Power Supply
AXP
PWR
AXM
GND
DEVICE
AXlink
ON
DATA
RADIO
AXlink
rear
front
FIG. 2 RF validation jumper settings
Wiring Specifications
Wire size Maximum wiring length
18 AWG 1805.7 feet (550.37 m)
20 AWG 1142.4 feet (348.20 m)
22 AWG 712.2 feet (217.07 m)
24 AWG 448.9 feet (136.82 m)
P3
P3
Setting for 3 validations Setting for 2 validations
Rear panel
DIP Switch DIP Switch
AMX Corporation reserves the right to alter specifications without notice at any time.
For full warranty information, refer to the AMX Instruction Manual(s) associated with your Product(s).
042-004-2728 5/03 ©2003
AMX Corporation. All rights reserved. The AMX logo is a trademark of AMX Corporation. AMX reserves the right to alter specifications without notice at any time.
3000 RESEARCH DRIVE, RICHARDSON, TX 75082 • 800.222.0913 • fax 469.624.7153 • technical support 800.932.6993 • www.amx.com
If you install the AXR-RF farther away from the Central Controller than
recommended in the Wiring Specifications table, an auxiliary ±12 VDC
power supply is required for operation.
Wiring the AXR-RF
The AXR-RF uses a rear 4-pin AXlink connector for power and data.
Power can be supplied by Central Controller's AXlink cable, or with an
optional auxiliary ±12 VDC power supply.
Using the AXlink 4-pin connector for data and power
Connect the Central Controller's AXlink connector to the AXlink connector
(male) on the rear panel of the AXR-RF for data and ±12 VDC power.
Using the AXlink 4-pin connector with an external ±12 VDC power supply
Use an auxiliary ±12 VDC power supply when the distance between the
Central Controller and AXR-RF exceeds the limits described in the Wiring
Specifications table. To use an external power supply, connect the Central
Controller's AXlink connector to the AXlink connector on the rear of the
AXR-RF, as shown in FIG. 4..
CAUTION: Do not connect the wire from the PWR (+) terminal on the
Central Controller to the PWR (+) terminal on the AXR-RF when you
connect an external power supply. Do not connect power to the AXR-RF
until the wiring is complete.
Connect only the GND (-) wire on the AXlink connector when using an
auxiliary ±12 VDC power supply. Do not connect the PWR (+) wire to the
AXlink connector's PWR (+) terminal on the Central Controller side of the
connector.
Installing the AXR-RF
1. Set the device DIP switch to assign an AXlink device code to the unit.
2. Install the wiring for the AXlink bus.
3. Position the AXR-RF in the location where it will be used. Place the
receiver close to, or in the middle of, the area to be covered. It is
recommended that you mount the unit where the antenna is away
from metal obstructions.
4. Extend the antenna vertically for best reception. If it is necessary to
place the antenna in a remote position, use up to 6 ft. (2 m) of
RG-174 coax cable.
5. Connect the AXR-RF to the Central Controller with the AXlink cable.
NOTE: To avoid potential problems with Axcess processing, do not install
two or more AXR-RF devices, using the same RF frequency, in one
system. The AXR-RF is available in frequencies other than 418 MHz (on
request).
6. Locate the green AXlink LED on the front panel and verify that it
flashes once per second. If so, the AXR-RF is communicating
properly with the Central Controller system.
If the LED is on and not flashing, disconnect the AXlink connector
and recheck all AXlink wiring connections. Reconnect the AXlink
connector to the AXR-RF and verify the LED is flashing once per
second.
FIG. 3 AXlink wiring diagram
FIG. 4 AXlink and 12 VDC power supply wiring diagram
PWR (+)
AXP
AXM
GND (-)
PWR
(+)
AXP
AXM
GND (-)
Central Controller
AXR-RF (3.5 mm connector)
PWR (+)
AXP
AXM
GND (-)
PWR (+)
AXP
AXM
GND (-)
AXR-RF (3.5 mm connector)
Central Controller
PWR (+)
GND (-) 12 VDC power supply

Other manuals for AXR-RF

1

This manual suits for next models

1

Other AMX Receiver manuals

AMX Viewpoint AXR-RF User manual

AMX

AMX Viewpoint AXR-RF User manual

AMX AXC-TEMP Guide

AMX

AMX AXC-TEMP Guide

AMX DTV-RX02-HD User manual

AMX

AMX DTV-RX02-HD User manual

AMX AXU-IR User manual

AMX

AMX AXU-IR User manual

AMX AutoPatch CAT-5 RGBHV RX User manual

AMX

AMX AutoPatch CAT-5 RGBHV RX User manual

AMX AutoPatch Cat5 S-Video+Stereo TX User manual

AMX

AMX AutoPatch Cat5 S-Video+Stereo TX User manual

AMX DXLink Multi-Format Wallplate User manual

AMX

AMX DXLink Multi-Format Wallplate User manual

AMX Sensors and Receivers IR User manual

AMX

AMX Sensors and Receivers IR User manual

AMX Endeleo Multi-Format Receiver UDM-RX02 Parts list manual

AMX

AMX Endeleo Multi-Format Receiver UDM-RX02 Parts list manual

AMX AXR-RF User manual

AMX

AMX AXR-RF User manual

AMX Endeleo Multi-Format Receiver UDM-RX02 User manual

AMX

AMX Endeleo Multi-Format Receiver UDM-RX02 User manual

AMX DXLink User manual

AMX

AMX DXLink User manual

AMX DXLink User manual

AMX

AMX DXLink User manual

AMX AXR-IRSM Plus User manual

AMX

AMX AXR-IRSM Plus User manual

AMX Mio Moderno MIO-IRRX User manual

AMX

AMX Mio Moderno MIO-IRRX User manual

AMX DX-TX Quick user guide

AMX

AMX DX-TX Quick user guide

AMX FG1010-37 User manual

AMX

AMX FG1010-37 User manual

AMX AXD-IR Plus User manual

AMX

AMX AXD-IR Plus User manual

AMX DXF-TX-MMD User manual

AMX

AMX DXF-TX-MMD User manual

AMX AXC-RCVI User manual

AMX

AMX AXC-RCVI User manual

AMX PMB-IRI User manual

AMX

AMX PMB-IRI User manual

AMX MAX-AVM User manual

AMX

AMX MAX-AVM User manual

AMX DCP-SRX User manual

AMX

AMX DCP-SRX User manual

AMX Mio Moderno MIO-IRRX User manual

AMX

AMX Mio Moderno MIO-IRRX User manual

Popular Receiver manuals by other brands

Wurlitzer 3020 Service Instructions and Parts Catalog

Wurlitzer

Wurlitzer 3020 Service Instructions and Parts Catalog

Federal Signal Corporation Tone Alert Installation and operation manual

Federal Signal Corporation

Federal Signal Corporation Tone Alert Installation and operation manual

SCS Sentinel RadioGate KIT quick guide

SCS Sentinel

SCS Sentinel RadioGate KIT quick guide

Danfoss R13 B user manual

Danfoss

Danfoss R13 B user manual

JVC KD-X480BHS quick start guide

JVC

JVC KD-X480BHS quick start guide

Sennheiser EK 3241 Instructions for use

Sennheiser

Sennheiser EK 3241 Instructions for use

Nexa WMR-2300 manual

Nexa

Nexa WMR-2300 manual

Lindsay Broadband LB-1000-FR user manual

Lindsay Broadband

Lindsay Broadband LB-1000-FR user manual

Williams Sound Digi-Wave DLT 400 user manual

Williams Sound

Williams Sound Digi-Wave DLT 400 user manual

Yamaha RX-V377 Easy setup guide

Yamaha

Yamaha RX-V377 Easy setup guide

Chauvet DMX-DFI user manual

Chauvet

Chauvet DMX-DFI user manual

Sony STR-DH550 reference guide

Sony

Sony STR-DH550 reference guide

Creative X-FI user guide

Creative

Creative X-FI user guide

Denon AVR 988 - AV Receiver Dimension Guide

Denon

Denon AVR 988 - AV Receiver Dimension Guide

Denon AVR 988 - AV Receiver manual

Denon

Denon AVR 988 - AV Receiver manual

Denon AVR 689 - AV Receiver owner's manual

Denon

Denon AVR 689 - AV Receiver owner's manual

steute RF Rx SW868-4S 48V Mounting and wiring instructions

steute

steute RF Rx SW868-4S 48V Mounting and wiring instructions

Pioneer Elite VSX-52 Features & specifications

Pioneer

Pioneer Elite VSX-52 Features & specifications

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.