anko KJ050GE-B1E2 User manual

Air Purifier
Model: KJ050GE-B1E2
User Manual
PLEASE READ AND SAVE THESE
INSTRUCTIONS FOR FUTURE REFERENCE

2
IMPORTANT SAFETY INSTRUCTIONS:
When using electrical appliance. Basic safety precautions
should always be followed including the following:
READ ALL INSTRUCTIONS BEFORE USING
All components need to be installed in accordance with the user
manual instructions for correct performance of unit.
The use of accessory attachments not recommended by the
appliance manufacturer may cause injuries.
A unit should never be left unattended while plugged in.
This appliance is not intended for use by persons (including
children) with reduced physical, sensory or mental capabilities, or
lack of experience and knowledge, unless they have been given
supervision or instruction concerning use of the appliance by a
person responsible for their safety.
Children should be supervised to ensure that they do not play
with the appliance.
Do not operate any appliance with a damaged cord or plug or
after the appliance malfunctions or has been damaged in any
manner.
If the supply cord is damaged, DO NOT use. For electrical safety,
any repairs to the product should only be carried out by a
qualified electrical person only or the product must be disposed.
Do not use appliance for other than intended use.
For electrical safety, do not attempt to adjust or repair the unit.
Servicing must be performed by a qualified electrical person only.
DO NOT use outdoors. For indoor use only.
Keep the rear air inlet and outlet free from blockages clothing,
plastic bags , paper or similar material. Proper air flow is required
for the unit to operate effectively.
Place unit on a flat location at least 30cm away from wall or other
appliances.
Keep the unit away from fire, flammable gas, combustible
products or vapours and corrosive substances.

3
DO NOT operate the unit in bathrooms or other humid
environments.
DO NOT operate where aerosol (spray) products are being used,
or where oxygen is being administered.
Do not operate the unit without filters.
Do not operate the product in any greasy environment, such as in
the kitchen. This product is not intended to filter oil or grease from
the air.
Electrical supply must be disconnected prior to cleaning.
NEVER drop or insert any object into any opening.
DO NOT carry this unit by the power cord or use the power cord
as a handle.
CAUTION
Never cover the unit while it is operating.
Always keep the cord away from high temperature and fire.
Stop using this unit if there is an unusual noise or smell.
Unplug this unit when not in use for a long period of time.
Do not run cord under carpeting. Do not cover cord with throw
rugs, runners, or similar coverings. Arrange cord away from traffic
area and where it will not be tripped over.
Do not touch the water or any parts of the unit that are covered by
water while the unit is switched ON or connected to mains power.
FOR HOUSEHOLD USE ONLY
READ AND SAVE THESE INSTRUCTIONS

4
FEAUTURES
2-Stage purification process
The 2-layer filter contains a Pre-filter and HEPA filter.
The Pre-filter traps larger particles such as dust, pet hair and large-sized
allergens.
The HEPA filter (Grade H11) removes 99.5% of particles as small as 0.3
microns and greater from the air. It is capable to remove smoke, dust,
pollen, pet dander and mould spores in the air.
Fan speed options
Allow selection for desired speed setting: low, medium and high.
Default setting at low speed.
Auto mode
In auto mode, the speed of the fan speed will change automatically
depending on the air quality as detected by the dust sensor.
Sleep mode
In sleep mode, the unit operates quietly at low speed. The on/off
indicator is dimmed and all other indicators are off.
Air quality indicator
The air purifier has a built-in air quality sensor to detect changes to
air quality in the surrounding area. Indicator will change colours
according to the quality of the surrounding air:
Grade
Air Quality
Colour of Light
1
Poor
RED
2
Fair
YELLOW
3
Good
BLUE

5
Filter Change indicator
Indicator will illuminate indicating that the filters need to be replaced.
To reset the indicator after the filter has been replaced, press and
hold the PRE-FILTER or HEPA FILTER button for 3 seconds.
Timer
Programmable timer to turn off the unit after a pre-set amount of
time. Press the “TIMER” button to program the timer at 2hr, 4hr, 6hr
and 8hr.
Child Lock
The control panel can be locked to inactivate the buttons.
IMPORTANT! Do not allow children to play with the air purifier.

6
PARTS
A. Air inlet grille
B. Locking latch
C. Pre-filter
D. HEPA filter
E. Control panel
F. Air outlet grille
G. Air quality indicator light

7
CONTROL PANEL
H. Indicators
a) Fan speed indicator
b) Child lock indicator
I. Timer display
J. Auto mode/ Sleep mode/ Child lock button
K. Fan speed button
L. On/Off button
M. Timer button
N. HEPA filter change indicator
O. PRE-filter change indicator

8
HOW TO USE
IMPORTANT! Before first use, open the air inlet grille by
pressing on the locking latch then pull. Unwrap the filters
before installing in the unit.
IMPORTANT! When placing the filters into the air purifier,
ensure the air inlet grille had locked into place or the unit will
not turn on.
1. Plug unit in to a 220-240V AC electrical outlet. POWER button
illuminates RED to show the unit is in standby mode.
2. Press the ON/OFF button to turn on the unit. The air quality
indicator light will illuminate, usually starting with a blue light until
it has time to sense the air quality and then it may change to an
alternate colour depending the air quality in the surrounding area.
3. The air purifier default setting is at Low speed.
4. To adjust the air purifier operates, follow the direction below.
Fan speed
To select speed, press FAN SPEED button repeatedly until the
desired fan speed is illuminated on the control panel. Fan speed will
cycle from Low, Med and High.
Auto mode/Sleep mode
Auto mode and Sleep mode utilise the same button. Pressing
AUTO/SLEEP button will cycle through these two settings.
Timer
To set automatic off timer, press TIMER button until timer display is
on desired time 2/ 4/ 6/ 8 Hr. Unit will automatically switch off once
selected time duration has lapsed.
Child lock
Press and hold the AUTO/SLEEP button for 3 seconds to activate
child lock function. The Child Lock indicator will illuminate. When the
child lock is on, all the other buttons are not responsive.
Press and hold the AUTO/SLEEP button for 3 seconds again to
deactivate the child lock.

9
CLEANING AND MAINTENANCE
CAUTION: Before cleaning, turn OFF and unplug the unit from
mains power .
External cleaning of unit:
Turn off and unplug the unit.
Use a soft cloth slightly dampened with a little water and dishwashing
soap to wipe the outer surfaces.
Do not allow water to slip into the internal parts as this could damage
the unit and result in electrical shock and injury.
Allow the unit to dry thoroughly before use.
Cleaning the Pre-filter and HEPA filter
Turn off and unplug the unit.
Release the air inlet grille by pressing on the locking latch then
pull.
Grasp the left and right side of HEPA filter frame and gently pull
out the filter.
Run a vacuum cleaner with brush attachment on low power
setting along the Pre-filter and HEPA filter to pick up the dust
and other particles.
Re-attach HEPA filter and the air inlet grille.
IMPORTANT! When placing the filters back into the air purifier,
ensure the air inlet grille had locked into place or the unit will
not turn on.
Note: It is recommended that the filters are cleaned every 100-
500 hours of operation, depending on the air quality in the room
and surroundings.

10
REPLACING FILTER
When the lifespan of the Pre-filter/ HEPA filter reach its end, discard
the old filter and replace with a new one.
The lifespan and duration of the filter depends on the air quality in
the surrounding environment. The higher level of pollutants, the
shorter the filter lifespan. It is advisable to change the filer at 8-12
months or when filter changing indicator light turns ON.
How to replace filter
Turn off and unplug the unit.
Release the air inlet grille by pressing on the locking latch then
pull.
Grasp the left and right side of HEPA filter frame and gently pull
out the filter.
Install a new HEPA filter in position, make sure back cover
had locked into place.
Press and hold the PRE-FILTER/ HEPA FILTER button for 3
seconds to reset HEPA Filter/ Pre-Filter Change Indicator.
IMPORTANT! When placing the filters back into the air purifier,
ensure the air inlet grille had locked into place or the unit will
not turn ON.
TECHNICAL DATA
MODEL NO.
KJ050GE-B1E2
VOLTAGE
220-240V
POWER CONSUMPTION
31 Watt
CLEAN AIR DELIVERY RATE
100m³/h
COVERAGE AREA
7-12m²

11
TROUBLESHOOTING
Some problems may be caused by minor faults that you can be
corrected yourself. To do so, follow the instructions in the following
table. If it is still not possible to resolve the problem, contact Kmart
customer service. Do not attempt to repair the air purifier yourself.
Problem
Possible cause
Solution
Power Light is
off/
No power
Unit is not
plugged in
• No power at
outlet
• Plug the unit to mains
supply, press the
POWER button
to turn the power on
• Check circuits and
fuses or
try a different outlet
Reduced
airflow or
Poor filtering
• Air inlet or
outlet may be
blocked
• HPEA filter
may be clogged
• There must be at least
30cm between unit and
wall or other
appliances.
• Remove any
blockages that cover
the air inlet/outlet.

12
12 Month Warranty
Thank you for your purchase from Kmart.
Kmart Australia Ltd warrants your new product to be free from
defects in materials and workmanship for the period stated above,
from the date of purchase, provided that the product is used in
accordance with accompanying recommendations or instructions
where provided. This warranty is in addition to your rights under the
Australian Consumer Law.
Kmart will provide you with your choice of a refund, repair or
exchange (where possible) for this product if it becomes defective
within the warranty period. Kmart will bear the reasonable expense
of claiming the warranty. This warranty will no longer apply where
the defect is a result of alteration, accident, misuse, abuse or neglect.
Please retain your receipt as proof of purchase and contact our
Customer Service Centre on 1800 124 125 (Australia) or 0800 945
995 (New Zealand) or alternatively, via Customer Help at
Kmart.com.au for any difficulties with your product. Warranty claims
and claims for expense incurred in returning this product can be
addressed to our Customer Service Centre at 690 Springvale Rd,
Mulgrave Vic 3170.
Our goods come with guarantees that cannot be excluded under the
Australian Consumer Law. You are entitled to a replacement or
refund for a major failure and compensation for any other reasonably
foreseeable loss or damage. You are also entitled to have the
goods repaired or replaced if the goods fail to be of acceptable
quality and the failure does not amount to a major failure.
For New Zealand customers, this warranty is in addition to statutory
rights observed under New Zealand legislation.
Table of contents
Other anko Air Cleaner manuals