Anly H5KLR User manual

NAMES AND FUNCTIONS OF FACEPLATESPECIFICATIONS
SETTING PROCEDURE
Product is subject to change without notice.
RESET
H5KLR
K/P
RESET
CP1
CP2
RUN
OUT1
OUT2
Set1
Set2
POWER ON or
RESET
Reset
INPUT MODE
OUTPUT MODE
OUTPUT 2 TIME
OUTPUT 1 TIME
MINIMUM RESET TIME
DECIMAL POINT
PRESCALE VALUE
KEY PROTECTION LEVEL
POWER OFF MODE
COUNT SPEED
Change
the mode
RESET
Save and back to the
operation mode
Switch to output 2 time
setting mode
Change
the set value
Switch to output
setting mode
Change
the mode
Switch to count speed
setting mode
Change
the set value
Switch to output 1 time
setting mode
Change
the set value
ϡʳNot available for Mode N and Mode F
Switch to reset time
setting mode
Change
the set value
Switch to prescale value
setting mode
Change
the set value
Switch to key protection level
setting mode
Switch to the position of
decimal point setting mode
Move the decimal
point position
Change
the set level
Switch to power off
setting mode
Change
the mode
Switch to Input
setting mode
ϡUP/DOWN MODE not available on ASK-4DRϭ, H5KLR-8/-11 type
Changing the digit
of prescale value
H5KLR
MULTI-FUNCTION DIGITAL COUNTER
User's Manual
SAFETY PRECAUTION
This manual uses the following symbols to ensure safe operation of this timer.
WARNING
CAUTION
Warnings are indicated when mishandling this product might result in death or serious injury
Cautions are indicated when mishandling this product might result in minor injury to the user,
to user.
or only physical damage to the timer.
ΘNote this incorrect wiring of this product can damage it and lead to other hazards. Make sure the product has
been correctly wired before turning the power ON.
ΘBefore wiring, or removing / mounting the product, be sure to turn the power OFF. Failure to do so might cause
electric shock.
ΘDo not touch electrically charged parts such as the power terminals. Doing so might cause electric shock.
ΘDo not disassemble the product. Doing so might cause electric shock or faulty operation.
ΘUse the product within the operating ranges recommended in the specification (temperature, humidity, voltage,
shock, mounting direction, atmosphere and etc.). Failure to do so might cause fire or faulty operation.
ΘFirmly tighten the wires to the socket. Insufficient tightening of the wires to the socket might cause fire.
WARNING
CAUTION
When using this product in applications
that require particular safety or when
using this product in important facilities,
please pay attention to the safety of the
overall system and equipment. Install fail-
safe mechanisms, perform redundancy
checks and periodic inspections and
adopt other appropriate safety measures
when it is necessary.
RESTRICTIONS ON USE
Operating voltage
Allowable operating
voltage range
Rated frequency
Contact rating
Count speed
Power consumption
Life
Ambient temperature
Ambient humidity
Weight
Mechanical : 5,000,000 times / Electrical : 100,000 times
85 ~ 110% of rated operating voltage
50 / 60Hz
MAX 30 cps or 1,000 cps
250VAC 5A (Resistive load)
Approx. 2.5VA
-10Д+50°C
MAX 85% RH
Approx. 120g
AC/DC : 12Д48V / AC/DC : 100Д240V
RESET
Upper display
Display PV values (current count values,
etc.) or setup items.
Performing arithmetic shift operations and
switches the display. Hold down for at least
3 seconds to enter setting modes.
Lower display
Display SV values (set count values, etc.)
and other parameter values.
key :
Used for incrementing or decrementing
numeric values. And show the first set value
or second set value.
LEDs
RUN: Counting indicator
OUT1: Control output 1 indicator
OUT2: Control output 2 indicator
RESET: Reset indicator
CP1: Signal input 1 indicator
CP2: Signal input 2 indicator
Set1: 1st set value indicator
Set2: 2nd set value indicator
K/P: Key protection indicator
key :
Reset the output or save the value
of setting.(after save than back to
the operation mode)
key :
RESET
Mode N
Mode F
Mode C
9999
999.9
0.01~9.99
99.99
Lock function key
Lock reset key
Power off reset
Power off memory
Lock preset value key
Lock all key
Mode R
Mode K
Mode P
Mode Q
Mode A
0.01s
0.05s
0.1s
0.2s
0.5s
1s
2s
10s
20s
5s
0.01s
ϡAvailable on H5KLR-11 type only
Hold
0.05s
0.1s
30 cps
1k cps
20ms
1ms
0.2s
0.5s
1s
2s
10s
20s
5s
UP
DOWN
UP/DOWN A
UP/DOWN B
UP/DOWN C
SPECIAL FUNCTION KEY
ON / OFF Key
protect
PRESS FOR 3s PRESS FOR 3s
Switch to input setting mode
RESET
Switch to input setting mode
(1)Stop (2)Counting
PRESS
FOR 3s
PRESS
FOR 3s
or
or
RESET
Save and back to the
operation mode
or
RESET
Save and back to the
operation mode
or
RESET
Save and back to the
operation mode
or
RESET
Save and back to the
operation mode
or
RESET
Save and back to the
operation mode
or
RESET
Save and back to the
operation mode
or
RESET
Save and back to the
operation mode
or
RESET
Save and back to the
operation mode
or
RESET
Save and back to the
operation mode
or
Switch to input setting mode
RESET
See reverse page for more details
TIMING CHART
DIMENSION(mm)
CONNECTION
Printed in Taiwan
M-H5KLR_I-G-A
ANLY ELECTRONICS CO., LTD.
http://www.anly.com.tw
H5KLR H5KLR + Y-50 + US-08
RESET
H5KLR
K/P
RESET
CP1
CP2
RUN
OUT1
OUT2
Set1
Set2
45+0.5
-0
45+0.5
-0
RESET
H5KLR
K/P
RESET
CP1
CP2
RUN
OUT1
OUT2
Set1
Set2
45+0.5
-0
45+0.5
-0
Output mode N
Output :
Up
Reset
9999
Preset 2
Preset 1
0
Output 1
Output 2
Down Up / Down A.B.C Up Down Up / Down A.B.C
Up Down Up / Down A.B.C Up Down Up / Down A.B.C
Up Down Up / Down A.B.C Up Down Up / Down A.B.C
Up Down Up / Down A.B.C Up Down Up / Down A.B.C
Output mode F
Output mode Q
Output mode A
Reset
9999
Preset 2
Preset 1
0
Output 1
Output 2
Output mode C
Output mode R
Output mode K
Output mode P
Reset
9999
Preset 2
Preset 1
0
Output 1
Output 2
Reset
9999
Preset 2
Preset 1
0
Output 1
Output 2
Reset
9999
Preset 2
Preset 1
0
Output 1
Output 2
Reset
9999
Preset 2
Preset 1
0
Output 1
Output 2
Reset
9999
Preset 2
Preset 1
0
Output 1
Output 2
Reset
9999
Preset 2
Preset 1
0
Output 1
Output 2
Output and present value display are maintained until reset. Present value runs continuously. Output 1 is self-holding, and goes off after expiration of the 1-shot period for
Output 2. One-shot time periods for Output 1 and 2 are independent.
Present value display runs continuously. Outputs are maintained until reset. Present value display does not change during 1-shot time period, but reset start status is returned to as soon
as count is reached. Outputs are 1-shot and operate repeatedly. Output 1 is self-holding, and goes off after
expiration of the 1-shot period for Output 2. One -shot time periods for Output 1 and 2 are independent.
Present value is placed in reset start status as soon as count up is reached. The count up is not displayed.
Outputs are 1-shot and operate repeatedly. Output 1 is self-holding, and goes off after expiration of the 1-shot
period for Output 2. One -shot time periods for Output 1 and 2 are independent.
Present value runs continuously through 1-shot time period and returns to reset start status immediately
afterward. Outputs are 1-shot and operate repeatedly. Output 1 is self-holding, and goes off after expiration
of the 1-shot period for Output 2. One -shot time periods for Output 1 and 2 are independent.
Present value is placed in reset start status as soon as count up is reached. Outputs are 1-shot and operate
repeatedly. Output 1 is self-holding, and goes off after expiration of the 1-shot period for Output 2. One -shot
time periods for Output 1 and 2 are independent.
Present value and output 1 maintain status until reset. Output 1 and 2 operate independently.
One-shot output from Output 1
Self-holding output
One-shot output from Output 2
Self-holding output
H5KLR-8 H5KLR-8B H5KLR-11 H5KLR-11M
H5KLR-11MI
3
21
8
9
10
11
7
6
5
4
SOURCE
RESET
CP1
(0V)
(RESET)
(
INPUT
)
OUT1 OUT2
4
3
2
18
7
6
5
SOURCE
RESET
CP1
(0V)
(RESET)
(INPUT)
OUT2
4
3
2
18
7
6
5
SOURCE
CP1
RESET
CP2
(0V)
(RESET)
(INPUT 1)
(INPUT 2)
OUT2
H5KLR-8M
K / P : Key Protection
OUT2
3
21
8
9
10
11
7
6
5
4
SOURCE
CP2
CP1
K / P
(Sensor)
Common (0V)
+VDC*(50 mA)
Load
(-) (+)
RESET
(0V)
(INPUT 1)
(K/P)
(INPUT 2)
(RESET)
K / P : Key Protection
OUT2
3
21
8
9
10
11
7
6
5
4
SOURCE
CP2
CP1
K / P
(Sensor)
+VDC*(50 mA)
Load (-)(+)
RESET
(INPUT 1)
(K/P)
(INPUT 2)
(RESET)
4
3
2
18
7
6
5
SOURCE
OUT2
CP2 /
RESET
CP1
(Sensor)
+ VDC*
(50 mA)
Load
(-) (+)
(INPUT 2 /
RESET)
(0V)
(INPUT 1)
PNP type
NPN type NPN type
H5KLR-8I H5KLR-8BI
4
3
2
18
7
6
5
SOURCE
RESET
CP1
(+VDC*)
(RESET)
(INPUT)
OUT2
4
3
2
18
7
6
5
SOURCE
CP1
RESET
CP2
(+VDC*)
(RESET)
(INPUT 1)
(INPUT 2)
OUT2
PNP type PNP type
NPN type NPN type
H5KLR-11I
3
21
8
9
10
11
7
6
5
4
SOURCE
RESET
CP1
(+VDC*)
(RESET)
(INPUT)
OUT1 OUT2
PNP type
NPN type
*For H5KLR-11M, H5KLR-8I,
H5KLR-8BI, H5KLR-11I and
H5KLR-11MI, the supply
voltage (+VDC) is 9V, when
the operating voltage
(SOURCE) is 12~48V.
The supply voltage (+VDC)
is 12V, when the operating
voltage (SOURCE) is 100~
240V.

Popular Cash Counter manuals by other brands

Hengstler tico 731.2 operating instructions

Hengstler

Hengstler tico 731.2 operating instructions

TSI Instruments AEROTRAK 9310 quick start guide

TSI Instruments

TSI Instruments AEROTRAK 9310 quick start guide

Cashmaster Sigma 105 Frequently asked questions

Cashmaster

Cashmaster Sigma 105 Frequently asked questions

Conrad FC-2500 operating instructions

Conrad

Conrad FC-2500 operating instructions

HYOSUNG NH-1800CE Operator's manual

HYOSUNG

HYOSUNG NH-1800CE Operator's manual

Kolibri Signature user manual

Kolibri

Kolibri Signature user manual

DS Produkte AP2110 instructions

DS Produkte

DS Produkte AP2110 instructions

PRESTEL+GEMMER RALLYEMASTER SPORT Assembly and operating instructions

PRESTEL+GEMMER

PRESTEL+GEMMER RALLYEMASTER SPORT Assembly and operating instructions

HYOSUNG TNS MS500EL Operator's manual

HYOSUNG

HYOSUNG TNS MS500EL Operator's manual

Capetti Elettronica WLRD12-2DI user manual

Capetti Elettronica

Capetti Elettronica WLRD12-2DI user manual

PASCO PASPort PS-2117 instruction sheet

PASCO

PASCO PASPort PS-2117 instruction sheet

JAMAR Technologies TRAX Totalizer user manual

JAMAR Technologies

JAMAR Technologies TRAX Totalizer user manual

Hameg HM8021-4 manual

Hameg

Hameg HM8021-4 manual

Osaka CI 49 operating instructions

Osaka

Osaka CI 49 operating instructions

Royal Sovereign FS-550D owner's manual

Royal Sovereign

Royal Sovereign FS-550D owner's manual

Cassida C-880 user manual

Cassida

Cassida C-880 user manual

SBM SB-9 Service manual

SBM

SBM SB-9 Service manual

Keysight Technologies 53150A Service guide

Keysight Technologies

Keysight Technologies 53150A Service guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.